![Adam CBC 3M Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/adam/cbc-3m/cbc-3m_service-manual_2845933014.webp)
© Adam Equipment Company 2007
12
8.2 USING “2006” TO ENTER THE SERVICE PARAMETERS
After the jumper has been placed in the position shown, apply power to the scale.
The display will ask for a code number, “
Pn
“ on the Weight Display.
Enter the number 2006 when “
Pn
“ is displayed and then press
[Tare].
The displays will show the first parameters, called “
F1
” “
CAL
”.
To select another parameter press the
[U.Wt./Units]
key to advance through the
parameters.
Press the
[Tare]
key to enter a parameter.
To exit a parameter, press the
[Zero]
key.
The
Weight
window will show the parameter number and the
Unit Price
and
Count
windows will show the word describing the function.
When a parameter is entered by pressing the
[Tare]
key, the displays will guide you
through the parameter selected and the options available.
The parameters available are:
“F1”
“
CAL”
To
enter
the
Calibration
“F2”
“
rES”
Resolution
selection
“F3”
“
CAPA”
Select
capacity
“F4”
“
init” “ZEro”
Initial Zero Range
“F5”
“
rE” “ Zero”
Re-Zero range
“F6”
“
SCSivE” “ tArE”
Successive Tare Enable
“F7”
“
Ad” “CoUnt”
Display the A/D counts
“F8”
“
Zero”
Select
the
zero
mode
“F9”
“
Pin”
To set the password
“F10”
“
Lvd” “mode”
Low voltage detection
8.2.1
F1
-CALIBRATION
To enter the calibration parameter, press the
[Tare]
key when “
F1
” is displayed.
The display will instruct you to remove any weight from the scale, “
UnloAd
”. Press
[Tare]
.
Содержание CBC 3M
Страница 2: ... Adam Equipment Company 2007 ...
Страница 19: ...9 0 WIRING DIAGRAM Adam Equipment Company 2007 17 ...
Страница 20: ...10 0 MECHANICAL ASSEMBLY Adam Equipment Company 2007 18 ...
Страница 22: ...11 0 DISPLAY ASSEMBLY Adam Equipment Company 2007 20 ...