b) Position the tank on a secure surface, in a ventilated area, mak-
ing sure that it is securely fastened during transportation. ATTEN-
TION once full with diesel, the sloshing force could provoke tank
movements!
c) Unscrew the filler plug and fill up the tank with diesel after hav-
ing verified that pump is unplugged. For this operation wear ap-
propriate safety clothes and devices like glasses and gloves.
d) One the tank is full, close and secure the filler plug.
e) If part of the kit, calibrate the digital flowmeter Di-Flow In line.
(CALIBRATION paragraph)
ELECTRICAL INSTALLATION 12/24V
1. Connect the battery clips on the motor power cord to a suitable
battery, capable of delivering the necessary voltage and current
(see the Technical Data, back page of this manual)
• The RED clip is attached to the positive (+) battery terminal.
• The BLACK clip is attached to the negative (-) battery terminal
or to the vehicle frame.
2. If the power cable provided is not long enough, have it replaced
by an authorized electrician.
Avoid sparks that could cause a fire: Do NOT use a
patch cord to extend the power cables.
ELECTRICAL INSTALLATION 230V
The pump must be provided with a safety device of 30mA mini-
mum Din standard. The plug must be connected to an earthed
SHUKO socket. Do not cut or replace the provided plug.
Avoid sparks that could cause a fire: Do NOT use a
patch cord to extend the power cables.
OPERATIONS
AVOID HAVING PUMP RUNNING DRY FOR MORE THAN 3 MINUTES.
a) Open tank cover.
b) Before using the system, clean nozzle and hose from dirt.
c) Insert the nozzle into that to be filled up.
d) Connect the electrical cable to power supply as explained in para-
graph: ELECTRICAL INSTALLATION after having verified that pump
switch is on OFF(O)
e) Open the valve located at pump inlet.
f) Switch on pump motor.
g) Reset the DI-FLOW flowmeter to 0 by pressing the R button
h) Press nozzle lever to dispense.
i) When desired quantity or when the nozzle has automatically
closed, release the trigger.
j) Switch off pump immediately.
k) Reposition nozzle and hose into their login and rewind power
supply cable.
l) Close pump inlet valve and close tank cover.
MAINTENANCE
1. Inspect and clean the strainer on the inlet hose or pipe monthly.
2. Clean the metal “mouth” portion of the battery clips with steel
wool monthly to maintain good electrical connection to the battery.
3. Hoses should be inspected annually. Replace if cracked or worn.
4. Rotor and vanes will eventually wear, and should be replaced if pump
performance degrades. See the “Operational Problems” section to
determine if replacement is needed.
5. Drain hoses and pump and store in a clean, dry place when not in use.
®Teflon is a registered trademark of E.I. Du Pont De Nemours and Company.
PRELIMINARY OPERATIONS
Before making any type of operation, read atten-
tively this manual..
a) Using the key supplied with the unit, open the tank cover,
make sure that during tran sport thank has not been damaged.
2
TECH TANK
•
1.
2.
3.
4.