background image

NB PERFORMANCE OF UNAUTHORIZED MODIFICATIONS TO 
“ADAM PUMPS” AUTOMATICALLY VOID WARRANTY OF ANY AND 
ALL RESPONSIBILITY ‘CIVIL AND CRIMINAL CHARGE OF THE 
SAME.

  GENERAL DESCRIPTION
  INSTALLATION & OPERATION
  MAINTENANCE & REPAIR
  PARTS LIST

Read and understand this Operating Manual before starting 
installation, maintenance or repair.

GENERAL DESCRIPTION AND ALLOWED USE

This diesel transfer system is designed for the delivery of diesel fuel 
(also for heating fuel and antifreeze) to vehicles and equipment from 
an open surface storage tank.  The pump is a self priming, positive 
displacement, rotary vane machine which operates on 12V DC power  
(models for 24V DC power are available), and delivers a flow of  
approximately 40 litres per minute.  The pump has a built-in bypass 
valve that keeps the operating pressure below 1.3 Bar (18 psi).  The 
motor has a 30 minute duty cycle.

SAFETY PRECAUTIONS AND FORBIDDEN USE

Improper use or installation of this product can 
cause serious bodily injury or death!

• Not for use with gasoline, alcohol, or other liquid  
  with a flash point below 40°C (104°F)
• Not for use in hazardous locations.
• Not for use with fluids thicker than diesel fuel.
• Not for use to transfer fluids into an aircraft.
• Not for use with fluids for human consumption.
• Not for dispensing water.
• Not for continuous duty applications.

EC COMPLIANCE STATEMENT

ADAM PUMPS ITALIA SPA, Via della Resistenza, 46/48, 
41011 Campogalliano (Modena) - Italy, states.This system has been 
designed for stocking, transport and transfer of diesel fuel for vehicles 
or machines (see forbidden use paragraph). The flow comply with 
the Directive for Machines 89/392/CEE (91/368/CEE, 93/44/CEE, 
93/68/CEE), 89/336/CEE (93/68/CEE), 73/23/CEE, and with stand-
ards EN 60529, EN 60204-1, EN 55081-2. The TECH TANK system 
has been designed following total exemption normative 1.1.3.1C 
ADR. Declaring that the pump EN 55011C/.A, D.L. 277/91 and 
AC Tech 40, conforms to the harmonized EN 60529, EN 60204-1, 
EN 50081-2, EN 55011C/.A, DL 277/91. This document has been 
signed by:
Mr. Bernard Gilson, Via della Resistenza, 46/48, 
41011 Campogalliano (Modena) - Italy, Phone +39 059 528128, 
Fax +39 059 528437who has full legal authority to represent the firm 
in the European Community.  Dated, 1st of February 2008.

Machine Identification - Label (typical example)

This Operating Manual should be considered as part of the 

machine.  When the machine is sold, it must be transferred 

to the new owner.

ADAM PUMPS Italia Spa
Via della Resistenza 48
41011 Campogalliano
Modena Italy

Code : 2108510020802

ELETTR. KPT 12-40 FLT 25 CASS. PL. ROSS

12 Volt - 270 Watt - 18 A - 2800 r.p.m.
30 min. duty cycle 

Weight Kg.: 4

Manufacturer

Production 

date

Product code

Model

Technical

data

2 0 0 6

N O V

Содержание TECH TANK 210L

Страница 1: ...cabinets meter DC and AC pumps accessories repair kit MANUAL OPERATION AND MAINTENANCE TECH TANK 210L 440L ...

Страница 2: ...man consumption Not for dispensing water Not for continuous duty applications EC COMPLIANCE STATEMENT ADAM PUMPS ITALIA SPA Via della Resistenza 46 48 41011 Campogalliano Modena Italy states This system has been designed for stocking transport and transfer of diesel fuel for vehicles or machines see forbidden use paragraph The flow comply with the Directive for Machines 89 392 CEE 91 368 CEE 93 44...

Страница 3: ...TECH TANK 1 DISCHARGE HOOSE C TECH 40 PUMP IN LINE DIGITAL FLOWMETER RELIEF VALVE FILLER PLUG AUTOMATIC NOZZLE 60L CAP 2 TRANSFER GROUP COMPONENTS SUCTION OPENING CHIUSING VALVE ...

Страница 4: ...e a fire Do NOT use a patch cord to extend the power cables OPERATIONS AVOID HAVING PUMP RUNNING DRY FOR MORE THAN 3 MINUTES a Opentankcover b Beforeusingthesystem cleannozzleandhosefromdirt c Insertthenozzleintothattobefilledup d Connecttheelectricalcabletopowersupplyasexplainedinpara graph ELECTRICALINSTALLATIONafterhavingverifiedthatpump switchisonOFF O e Openthevalvelocatedatpumpinlet f Switch...

Страница 5: ...ey 3 Motor failure Clean out pump cavity Remove all debris replace key Return to place of purchase Low Flow 1 Excessive dirt in filter 2 Restriction on the outlet or in the inlet 3 Excessive rotor or vane wear 4 Low fluid level Remove and clean or replace filter Long and small ID hoses filters and automatic nozzles will reduce the flow rate Use higher flow components Replace rotor and vanes Fill t...

Страница 6: ...5 8 1 18 4 6 19 5 16 7 2 9 8 3 19 11 10 12 13 20 17 21 18 15 14 4 TECH TANK TECH TANK ...

Страница 7: ... N 1 1 3 1 C VERSIONS TECH TANK STANDARD 12v CC 24v CC 230v CA Voltage V 12 24 230 Flow l min 40 40 40 Cable m 4 4 2 Shut off valve sì sì sì Filler plug 2 2 2 Discharge hose m Ø 4 5 Ø 19 4 5 Ø 19 4 5 Ø 19 Nozzle automatic automatic automatic Meter no no no Safety valve vent 1 1 1 TECH TANK TOP 12 v CC 24v CC 230v CA Voltage V 12 24 230 Flow l min 40 40 40 Cable m 4 4 2 Shut off valve sì sì sì Fill...

Страница 8: ...R Ø77 231501700000 231501700000 1 3 PLATE AC DC TECH 40 DC006 DC006 1 4 SAVE CAP THREAD Ø25 163013300000 163013300000 2 5 BY PASS CAP 71000521 71000521 1 6 BY PASS SPRING Ø21 4X42 71008006 190110000000 2 7 BY PASS VALVE 71000520 71000520 1 8 SEALING RING Ø19 12010031000 12010031000 1 9 O RING 2212 NBR 18001014 18001014 1 10 PLASTIC KEY 71000517 71000517 1 11 ROTOR Ø45 61000003 61000003 1 12 VANE 7...

Страница 9: ...1 6 SWITCH HOLDER AC DC TECH 40 DC002 DC002 DC002 1 7 RIGHT SIDE AC DC TECH 40 DC004 DC004 DC004 1 8 LEFT SIDE AC DC TECH 40 DC003 DC003 DC003 1 9 SWITCH ON OFF 11X30 190050070000 190050070000 190050070000 1 10 SCREW TCCE M5X12 ISO 4762 13001013 13001013 13001013 2 11 FACEPLATE AC DC TECH 40 MA022 MA022 MA023 1 12 CABLE WITH CLAMP 2M FIG 8 17001010 17001010 1 13 FUSIBLE 30A FIG 8 190170150000 1901...

Страница 10: ...eter has a double Reed switch system to avoid false readings due to vibrations or erroneous installation and turbine reverse rotation The meter is threaded 1 BSP P female both at inlet and out let Sealing is made using O ring 30x3 70Sh 1 2 3 2 5 It is necessary if not already installed in the system to install a filter or screen of at least 40 mesh prior to the flow meter 3 2 1 ELECTRICAL WIRING F...

Страница 11: ...m will scroll between last 5 transactions To go back to partial screens wait 10 seconds without pressing buttons 3 4 0 SCROLLING THROUGH 5 MAIN SCREENS Starting from the Partial screen and at each time button is pressed following screens sequence will be displayed 1 Total preceded by message Total Litres 2 Total period preceded by message TotPer 3 Tank Stock preceded by message Stock 4 Minimum sto...

Страница 12: ...seconds until the partial screen I displayed 3 4 4 TANK STOCK SCREENS WITH MESSAGE STOCK displays 5 digits no decimal place settable at maximum 65000 litres Such number identifies the minimum stock in the tank under which the meter will display the alarm To set this alarm level go to Alert screens and press button Value on display will start blinking and will be then modifiable increasing the valu...

Страница 13: ...id after dis assembly at different temperature or after signif icant wear A proving container or a container of KNOWN volume will be needed for the calibration procedure It is recommended that the container volume be at least 19 liters 5 gallons 18 16 14 12 16 18 5 ATTENTON the system does not allow a cali bration if quantity transferred is under 5 litres Calibration procedure 1 Starting from Part...

Страница 14: ...ed to new calibration TOTAL and TOTAL PERIOD will remain unchan ged CUSTOM UNIT OF MEASURE Default factory setting is decalitre 1 10 litre This value can be configured as follows 1 Repeat operations 1 to 5 from paragraph 3 5 3 Selecting unit of measure 2 Once the choice of custom has been confir med pressing button the meter will propose the default value blinking 0 100 To obtain such a coefficien...

Страница 15: ...isualize first transaction in history visualize total of first two transactions in history visualize total of first three transactions in history visualize total of first four transactions in history visualize total of all transactions in history visualize total Total visualize period total totPer reset period total totPer visualize the Stock situation modify the value in Stock visualize minimum s...

Страница 16: ...l be low It will be necessary to change batteries 1 Rimove the 4 screws on the back of the meter 2 Exchange the 2 batteries with 2 AAA 1 5V alkali ne batteries 3 Reposition the body on the cover taking care of not squeezing wires 4 Screw the 4 screws to tighten the body to the cover 4 2 CLEANING THE TURBINE The meter has 2 magnets fitted into the turbine This magnets could attract metallic powders...

Страница 17: ...rbine 2 verify thanks to the arrow on the meter that it i correctly fitted on the line 3 contact your supplier to get an Exchange board 4 rotate the turbine by 180 1 change bat teries 2 verify batteries positioning 1 verify technical data on pump flow rate 2 calibrate 3 verify that pump is not sucking air 4 clean magnets 4 3 STOCK If the meter has to be positioned in stock for a while clean it car...

Страница 18: ...4 3 METER COVER TF035 1 4 ELECTRONIC PCB TF046 1 5 SCREWS M3 VT010 1 6 BATTERY AAA TF048 2 7 O RING OR018 1 8 BODY DIFLOW INLINE TF036 1 BODY DI FLOW INLINE UREA TF042 9 TURBINE SHAFT TF039 1 10 TURBINE HOLDER TF038 2 11 TURBINE TF037 1 12 MAGNET TF040 2 13 SELF BLOCKING BOLT VT009 1 14 SCREW M3 X 12 VT011 1 16 TECH TANK ...

Отзывы: