background image

26

34

35

10

11

26

29

30

28

31

32

33

25

13

22

12

2

3

16

1

4

20

24

21

14

6

15

17

9

7

8

5

23

27

18

19

Num. 

articolo

Num. parte

Descrizione

Quantità

1

ME033

Statore avvolto MEC 63 

1

2

ME032

Scudo lavorato MEC 63

1

3

ME034

Albero motore MEC 63

1

4

101001600000

Cuscinetto radiale a sfere 6201 2RS

2

5

OR037

GUARNIZIONE FUSTELLATA FILTRO PLISS.

1

6

OR038

Paraolio 10197 TCV molla inox 10X19X7

1

7

OR039

O-RING NBR70 57x2 CORPO POMPA

1

8

PA018

PIATTELLO DI CHIUSURA GIREVOLE

1

9

PA019

FILTRO INOX PLISSETTATO SU ASOLA 16x49

1

10

PA020

Condensatore 12.5 μF 450 V

1

11

PA024

STAFFA BLOCCA CONDENSATORE SAVIPLAST

1

12

PA025

Ventola MEC 63

1

13

PA026

ANELLO Ø12 PER VENTOLA MEC 63

1

14

PA029

DISTANZIALE CILINDRICO D.12,4X16 H11

1

15

CP009X

CORPO POMPA PA 70L X-TREME TRILOBATO

1

16

PA021

Linguetta 3x3x15 UNI 6604-B

1

17

61000003

Girante Ø45

1

18

71000522

Paletta piccola

5

19

71000520

Valvola by pass

1

20

71000521

Piattello

1

21

16001005

Molla by pass 60-80-100

1

22

140250500000

Copriventola  MEC 63

1

23

11010040200

O-Ring 2015 NBR

1

24

84500000000

Anello di compensazione - Øe 31,4 Øi 24,2

1

25

61004600000

Tirante  M5 x 125 con invito

4

26

PA023

Scatola portacondensatore

1

27

VT046

VITE TE M5X12 FLANGIATA LISCIA UNI5541

5

28

EL013

Interruttore basculante 22X30 + Cappuccio

1

29

140250300000

Blocca cavo

1

30

VT004

Vite TC Croce Ø3,5x16 Autofilettante UNI 6954

2

31

17001011

Gommino pressa cavo

1

32

17001012

Ghiera pressa cavo

1

33

190200000000

Cavo nero con spina schuko 230V

1

34

VT037

Vite TC Croce M4x6 Trilobata UNI 8112

5

35

VT049

VITE PER PLASTICA TC 3X8 BN13577 WN1412

4

4

3

2

1

A

B

C

D

E

F

8

7

6

5

12

11

10

9

G

H

A

B

C

D

E

F

G

H

12

11

10

9

8

7

6

5

4

3

2

1

Proprietà della  ADAM  PUMPS  Spa   -  Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la 

costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.

Formato

A2

Codice

Denominazione

1:20

Scala

Materiale

Revisioni

Rev.

RM n°

Data

Firma

Disegnato

1

Data

Tolleranze generali

UNI EN 22768-mK

Peso indicativo

Data

Approvato

1 di 1

Foglio

2

3

4

6

8

5

7

9

Proprietà

ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS)

EN

PA1 70A

POS.  CODE  

DESCRIPTION  

QTY

1  

ME033  

Wound stator MEC 63  

1

2  

ME032  

Shield worked MEC 63  

1

3  

ME034  

Engine shaft MEC 63  

1

4  

101001600000   radial ball bearing  6201 2RS  

2

5  

OR037  

die-cut plisset filter gasket  

1

6  

OR038  

Seal 10197 TCV inox spring 10X19X7  1

7  

OR039  

O-RING NBR70 57x2  

1

8  

PA018  

swivel locking plate  

1

9  

PA019  

inox filter16x49  

1

10   PA020 

Capacitor 12.5 μF 450 V  

1

11   PA024  

bracket block capacitor 

1

12   PA025  

fan MEC 63  

1

13   PA026  

fan mec 63 ring ø12  

1

14   PA029  

cylindrical spacer ø12,4X16 H11  

1

15   CP009X  

body pump pa 70l x-treme 

1

16   PA021  

pin 3x3x15 UNI 6604-B  

1

17   61000003  

impeller Ø45  

1

18   71000522  

small vane  

5

POS.  CODE  

DESCRIPTION  

QTY

19   71000520  

by pass valve  

1

20   71000521  

plate  

1

21   16001005  

by pass spring 60-80-100  

1

22   140250500000   fan cover mec 63  

1

23   11010040200   O-Ring 2015 NBR  

1

24   84500000000   compensation ring  Øe 31,4 Øi 24,2   1
25   61004600000   tie rod m5 x 125  

4

26   PA023  

capacitor box  

1

27   VT046  

screw te m5x12 flanged uni5541  

5

28   EL013  

Switch 22X30 + Cap 

 1

29   140250300000   cable lock   

1

30   VT004  

screw TC Croce Ø3,5x16  UNI 6954   2

31   17001011  

cable gland rubber  

 1

32   17001012  

cable gland ring nut  

1

33   190200000000   black cable with schuko plug 230V   1
34   VT037  

screw TC Croce M4x6 Tril. UNI 8112   5

35   VT049  

screw  tc 3x8 bn13577 wn1412  

4

Содержание PA 8050

Страница 1: ...ity Directive 2014 35 EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits Directive 2014 68 EU of the European Parliament and of the Council of 15 May 2014 on the harmonisation of the laws of the Member States r...

Страница 2: ... suction and discharge lines 5 4 Electrical connection of the pump 6 INTENDED USE 6 1 Preliminary checks and start up 6 2 Daily use 6 3 Noise level 6 4 Compatibility in an electromagnetic environment 7 TROUBLESHOOTING 8 MAINTENANCE 9 DEMOLITION AND DISPOSAL 10 WARRANTY 11 TECHNICAL SUPPORT 12 ATTACHMENTS 12 1 Exploded views and spare parts list 12 2 Wiring diagrams 12 3 Overall dimensions and weig...

Страница 3: ...L POWER SUPPLY MAXIMUM CURRENT AMP RATED POWER WATT WORK CYCLE MIN MAX FLOW RATE L MIN INPUT OUTPUT BSP G NOISE DBA PA1 70A 230V 50Hz AC 230V 50Hz 2 9 552W S1 Continuous 70 1 1 70 PA1 70A 230V 60Hz AC 230V 60Hz 3 5 667W S1 Continuous 70 1 1 70 PA1 70A 380V 50Hz AC 380V 50Hz 1 304W S1 Continuous 70 1 1 70 PA2 80 230V 50Hz AC 230V 50Hz 3 5 700W S1 Continuous 80 1 1 80 PA2 100 230V 50Hz AC 230V 50Hz ...

Страница 4: ...sition pump axis either horizontal or vertical in a place sheltered from 4 TRANSPORT AND HANDLING 4 1 Transport The weight and dimensions of the pump allow it to be easily transported by hand The pump does not require lifting equipment to move it 3 3 Allowed fluids forbidden fluids Allowed DIESEL FUEL with 2 to 5 5 cSt viscosity at 38 C Minimum flash point MF 55 C Forbidden PETROL FLAMMABLE LIQUID...

Страница 5: ... cavitation phenomena can start with consequent reduction of the flow rate and increase in noise To prevent this phenomenon from occurring it is important to ensure low suction negative pressure by using short pipes or pipes with a diameter larger than or the same as those recommended minimising bends and using large section suction filters and foot valves with the least resistance possible Moreov...

Страница 6: ...iagram to the side For proper installation and electrical maintenance of the system please follow these instructions make sure the power lines are not live when installing or carrying out maintenance operations on the system use cables with minimum section rated voltages and type of installation suitable for the system s specifications make sure the three phase motors are rotating in the right dir...

Страница 7: ...ump The machine is designed to operate correctly in an industrial electromagnetic environment and staying within the Emission and Immunity limits laid down in the following Harmonised Standards IEC EN 61000 6 2 Electromagnetic compatibility EMC Generic standards Immunity for industrial environments IEC EN 61000 6 4 Electromagnetic compatibility EMC Generic standards Emission standard for industria...

Страница 8: ... Replace the damaged components Excessive negative pressure to the suction line Make sure there are no leaks or restrictions on the suction part recommended pipes chap 5 2 High pressure drops in the circuit Change the hydraulic discharge configuration Bypass valve open or blocked Check the condition of the valve and clean or replace it if necessary Vanes blocked Check and clean the vanes and their...

Страница 9: ...eel are usually recycled by companies specialised in the scrap metal industry ELECTRICAL AND ELEC TRONIC COMPONENTS These must be disposed of by companies specialised in disposing of electronic components in compliance with the requirements of Directive 2002 96 EC see Directive text below PARTS OF A DIFFERENT NATURE Other parts of the system in which the electric pump is installed such as pipes ru...

Страница 10: ... out only by Adam Pumps or by Adam Pumps authorised centres the warranty will not be valid in the event the product is tampered with by unauthorised persons bodies and or companies any warranty request is subject to approval by Adam Pumps The goods can be returned only if provided with an authorisation code Upon request Adam Pumps will provide this code which will invoke the warranty for the produ...

Страница 11: ...pring 10X19X7 1 7 OR039 O RING NBR70 57x2 1 8 PA018 swivel locking plate 1 9 PA019 inox filter16x49 1 10 PA020 Capacitor 12 5 μF 450 V 1 11 PA024 bracket block capacitor 1 12 PA025 fan MEC 63 1 13 PA026 fan mec 63 ring ø12 1 14 PA029 cylindrical spacer ø12 4X16 H11 1 15 CP009X body pump pa 70l x treme 1 16 PA021 pin 3x3x15 UNI 6604 B 1 17 61000003 impeller Ø45 1 18 71000522 small vane 5 POS CODE D...

Страница 12: ...ld mec 71 15502600000x 1 16 tie rod m5 x 135 znb 6100450000z 4 17 fan mec 71 ring ø14 140260400000 1 18 fan cover mec 71 140260500000 1 19 key 6 x 6 x 20 90505050000 1 20 capacitor 190061000000 1 POS DESCRIPTION CODE QTY 21 black power cable 190200000000 1 22 bypass valve 71000520 1 23 pump body 80l 1 bsp g 71000060 1 24 bypass spring 16001005 1 25 plate 71000521 1 26 or 3118 nbr 18001008 1 27 cap...

Страница 13: ...l filter 41410000 1 7 or 3118 nbr 18001008 1 8 cap 1 17001094 1 9 filter plate 71000587 1 10 filter cleaning plate 71000546 1 11 sealing ring 20307 12001015020 1 12 impeller ø72 61000010 1 13 large vane 71000569 7 14 or 85 x 3 nbr 18001022 1 15 large disc 71000063 1 16 socket head screw m5 x 16 znb 13001007 4 17 danger label 71000653 1 18 ce label 220000000000 1 19 thread protection cap ø31 163013...

Страница 14: ... protection cap ø31 163013500000 2 7 pump body 150l 71000061 1 8 bypass valve 71000520 1 9 bypass spring 16001005 1 10 plate 71000521 1 11 sealing ring 20x30x7 SNBR 12001015020 1 12 large stainless steel filter 41410000 1 13 O Ring 3118 NBR 18001008 1 14 cap 1 17001094 1 15 filter label 71000587 1 16 key 6x6x20 UNI 6604 A 90505050000 1 17 ce label 1 18 motor 150l me002 1 19 danger label 71000653 1...

Страница 15: ...ECH 230 Vac da 60 80 100 L Denominazione 1 1 Scala Materiale Revisioni Rev RM n Data Firma anicardi M 11 2014 1 e generali N 22768 mK Peso indicativo 27 11 2014 Data Stassi Davide Approvato 2 3 4 6 8 5 7 9 1 2 3 4 rietà SCHEMA ELETTRICO L N S1 M A C 230 Vac C1 T S1 Interruttore ON OFF Cs 1 2 3 4 ENGLISH TRANSLATION OF ORIGINAL INSTRUCTIONS EN PA1 70 PA2 80 PA2 100 PA3 150 12 2 Wiring diagrams S1 O...

Страница 16: ...00 PA 1 70 Proprietà della ADAM PUMPS Spa Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la costruzione dell oggetto rappresentato nè venire comunicato a terzi o riprodotto La società proprietaria tutela i propri diritti a rigore di legge A 7000 ENGLISH TRANSLATION OF ORIGINAL INSTRUCTIONS 12 3 Overall dimensions and weights ...

Отзывы: