background image

Adam Pumps S.p.A. 

Soc. con Socio Unico

via della resistenza 46/48 - 41011 Campogalliano (MO) ITALIA

Tel +39 059 528128 - Fax +39 059 528437

www.adampumps.com - [email protected]

UM021

7/2020 - rev. 5

G FLOW, G FLOW PULSI, 

G FLOW REED

ITALIANO 

(lingua originale)

ENGLISH 

(translation of original instructions)

IT

EN

Содержание G FLOW

Страница 1: ... resistenza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM021 7 2020 rev 5 G FLOW G FLOW PULSI G FLOW REED ITALIANO lingua originale ENGLISH translation of original instructions IT EN ...

Страница 2: ...a justified request from ADAM PUMPS S p a or by sending a request to info adampumps com The person authorised to compile the technical file and draw up the declaration is Davide Stassi as legal representative Place and date of the document Campogalliano January 14 2020 The legal representative TABLE OF CONTENTS 1 GENERAL WARNINGS 2 SAFETY INSTRUCTIONS 2 1 Safety measures 2 2 First aid 2 3 Protecti...

Страница 3: ... All rights under these rules belong to ADAM PUMPS S p A reproduction even partial of this manual its publication modification transcription public disclosure distribution marketing in any form translation and or development loan or any other activity reserved by law to ADAM PUMPS S p A 2 3 Protective devices Protective equipment characteristics Wear equipment that is appropriate for the operation...

Страница 4: ...WATER The LCD display on the G FLOW has a numerical register and different instructions that are displayed only when appropriate 1 Partial register total register and instructions ALERT STOCK and PARTIAL TOTALISER 2 Flat battery indicator 3 TOTAL key 4 RESET key The regular shape of the G FLOW meter allows the LCD display mask to rotate in 90 steps To rotate the LCD screen 1 Unscrew the 4 screws h...

Страница 5: ... screens The device automatically switches on when dispensing starts or when either the Reset key R or the Total key T is pressed once The display automatically switches off if no operation is performed or if no signal is detected for 120 consecutive seconds Each time the meter is switched off the Partial screen is reset therefore it does not need resetting at the first refuelling after switch off...

Страница 6: ...ispensedinacertainperiodoftime Thisnumber canberesetbypressing Access by pressing Displaying 5 digits no decimal point shows the remaining stock in the storage tank To set this stock go to the Stock screen and press The value displayed will start flash ing and can then be changed as required by pressing to increase it or o decrease it To quickly increase or decrease it press and hold or To confirm...

Страница 7: ... signals a Stock alert To set this stock go to the Alert screen and press The value displayed will start flashing and can then be changed as required by pressing to increase it or to decrease it To quickly increase or decrease it press and hold or To confirm wait 10 seconds without pressing any key until the meter automatically returns to the Partial screen NOTE The alert is disabled if 0 is set 6...

Страница 8: ... 14 14 12 12 16 18 5 16 18 5 6 4 Custom unit of measurement The CUSTOM unit of measurement is factory set at a decalitre 10 litres This value can be set by the customer as follows Repeat the operations from point 1 to point 5 in paragraph 3 5 3 Selecting the unit of measurement When the meter has con firmed the custom unit of measurement with it will propose the flashing default value of 0 100 To ...

Страница 9: ...ctor pul l CAL 40 00 5 Supply voltage in Volts bat Vol 2 79 if the value is than 2 8V otherwise the word FULL is dis played 6 Remaining battery charge percentage bat Per 52 95 displayed only if the supply voltage is 2 8 Volt If the supply voltage reaches 1 5 Volt the battery symbol will appear flashing on the bottom right Below 0 6V the display will no longer be visible and the batteries will have...

Страница 10: ...l on the product and or on the packaging is not to be disposed of with unsorted municipal waste The symbol indicates that this product must not be disposed of with normal household waste It is the responsibility of the owner to dispose of these products and the other electrical and electronic equipment through specific collection facilities appointed by the government or by local authorities 10 WA...

Страница 11: ...in general 11 TECHNICAL SUPPORT The Manufacturer is always available for any information required on installation operation or maintenance of the machine The Customer should ask the questions clearly with reference made to this Manual and to the instructions listed Always remember to specify the type of product and the production date on the label under the LCD display mask G Flow display version ...

Страница 12: ...i 70 994 70 994 70 994 Precision 0 3 0 3 0 5 Repeatability 0 2 0 2 0 2 Display rotation Complete with 90 steps Input Output BSP G Flange 1 F Flange 1 F Flange 1 F Body material Aluminium Aluminium Aluminium Gear material POM C POM C POM C O Ring material NBR NBR NBR Other materials in contact with the fluid Brass Steel NdFe Brass Steel NdFe Brass Steel NdFe Min max operating temperature C 10 60 10...

Страница 13: ...1 Data Tolleranze generali UNI EN 22768 mK SW Massa kg Peso indicativo 02 12 2015 Data Approvato Proprietà Componente Adam Pumps CODE DESCRIPTION QTY DISPLAY PULSE OUT 1 TF066A TF066A METER BODY 1 2 TF065A TF065A FLANGE 1 3 VT040 VT040 SCREW TC M5x16 4 4 OR011 OR011 O RING 37 x 3 NBR 4 5 VT045 VT045 SCREW TBEI M8X25 ZNB 4 6 TF070 TF070 CEMENTED PIN 5X60 2 7 TF040 TF040 MAGNET Ø3x6 4 8 TF071 TF071 ...

Страница 14: ...TF065A Cover 1 3 TF064 Inlet flange 2 4 OR011 O Ring 37 x 3 4 5 TF070 cemented pin 5x60 2 6 TF040 Magnet Ø3 4 7 TF071 cemented pin 3x14 2 8 TF018 calibration cap 1 8 1 9 11010100200 O Ring 108 1 10 TF068 oval wheel 4 11 OR033 O Ring 6 532 1 CODE DESCRIPTION QTY 12 TF076 Inlet filter 1 13 TF072 Cover plate 1 14 AC005 Cable gland 1 15 VT036 Nylon Washer 2 20 OR031 O Ring 2 142 1 17 TF077 cemented pi...

Отзывы: