1. G���R�� ����R� 

1.1  ���R�DU������

This flow meter has been designed for mea-
suring the transfer of Diesel, AddBlue® depen-

Diesel, AddBlue® depen-

ding of purchased model. It is not to be used to

It is not to be used to 

measure for resale purposes. 

NOTICE: ANY MODIFICATION TO THIS ME-
TER WITHOUT “ADAM PUMPS” WRITTEN 
PERMISSION WILL VOID ANY GUARANTEE 
AND FREE “ADAM PUMPS” FROM ANY 
RESPONSIBILITY��

1.2  F�R�W�RD 

This manual has been made to give the user a 
general  knowledge  about  the  equipment  and 
the  necessary  maintenance  and  ope-ration 
instructions.  Carefully  read  and  understand 
this manual before starting installation, main-
tenance  or  repair.  Maintenance  schedules 
proposed  in  this  manual  are  meant  to  be  the 
minimal required for efficiency, safety and en-
durance of the equipment in normal operating 
conditions. Be observant for any type of mal-
function or potential safety issue at all times. 
Disconnect  electrical  power  before  removing 
protective covers as prescribed by the Stand-
ard  292/2  Nov.  1992.  for  maintenance,  repair 
and general lubrication by authorized person-
nel.

1.3  �R����U�����

Improper  use  or  installation  of  this  product 
can cause serious bodily injury or death!
To  ensure  safe  and  efficient  operation,  it  is 
necessary  to  read  and  follow  each  of  these 
warnings and precautions:
•  Do NOT smoke near meter or use meter near 
an open flame;
•  This  product  should  NOT  be  used  for  fluid 
transfer into aircraft;
• Any type of service, maintenance, control must 
be done by qualified personal. 
•  During maintenance operations and services, 
make sure to have disconnected the power supply. 
•  Do not exceed the maximum pressure of 3,5 bar

1.4   G���R�� ��F��Y ��R�� 

Always wear a protection equipment that is suita-
ble to the operations to carry out according  to the 
liquid that is being used. If any doubt review the 
product safety sheet. During installation, use  and  
maintenance  always wear the correct protection 
equipment:
- gloves
- glass
- shoes
- clothings

1.5   

DISCARDING AND RECYCLING

The metallic parts must be separated and sent 
to appropriate metal recycling mills.
The fuels in the tanks of the installation will be 
collected and sent to an authorized disposer. 
All plastic and non-degradable material parts 
will be separately collected and sent to an au-
thorized disposer or recycler.
In conformity with the European Directive 2002/96/
EC concerning the elimination of electric and elec-
tronic equipments, (WEEE), the symbol herewith on 
the  pump  and/or  on  its  packaging  indicates  that 
you have to dispose of packaging for the product 
in a responsible manner. It is suitable for recycling.  
Help to protect the environment, take the packag-
ing to the local recycling service and place into the 
appropriate recycling bin.
Never dispose of electrical equipment or batteries 
in with your domestic waste. If your supplier offers 
a disposal facility please use it or alternatively use 
your local recycling service and dispose in the cor-
rect manner. This will allow the recycling of raw ma-
terials and help protect the environment.

Содержание DI-FLOW IN-LINE AdBlue

Страница 1: ...cabinets meter DC and AC pumps accessories repair kit USE AND MAINTENANCE MANUAL DIGITAL FLOW METER IN LINE IN LINE 12V pulses version ...

Страница 2: ...en designed and built for INSTALLATION IN NORMAL WORKING CONDITIONS according to CEI standards 17 13 6 1 This use and maintenance manual and related EC certification of compliance should be considered as part of the machine if the machine is sold they must be handed down to new owner 0 EC COMPLIANCE STATEMENT ADAM PUMPS SPA Via della Resistenza 46 48 41011 Campogalliano Modena Italy states taking ...

Страница 3: ...t Any type of service maintenance control must be done by qualified personal During maintenance operations and services make sure to have disconnected the power supply Do not exceed the maximum pressure of 3 5 bar 1 4 General SAFETY NORMS Always wear a protection equipment that is suita ble to the operations to carry out according to the liquid that is being used If any doubt review the product sa...

Страница 4: ...ween Litre Gallon Pint Quart of Custom configured by the customer For major information about these option refer to the appropriate paragraph 2 3 AUTHORIZED FORBIDDEN USE The flowmeter can be used with different fluids depending of purchased version 1 DI FLOW IN LINE Diesel black meter body Diesel Kerosene for heating Solvents Anti freeze Light oils max cinematic viscosity 300 cSt 2 Di FLOW IN LIN...

Страница 5: ... cover total button display reset button battery alter simbol 1 2 3 3 2 1 ELECTRICAL WIRING FOR PULSER VERSION If you bought our pulser model the flowmeter is fitted with a 2m cable with 5 internal wirers to be connected as follows 1 Yellow wire power 12 Vdc 2 Brown wire power 0 Vdc 3 Green wire pulser channel 100 imp unit 4 White and grey wires Relay contact should you desire to control the pump ...

Страница 6: ...s at transaction start An active meter will go back to this screens after 10 seconds without activity This screen is used as initial condition to describe other 4 available screens displays 6 digits no decimal shows all litres transferred since first use Cannot be reset 3 4 MAIN FUNCTIONS The meter switches on automatically when a transaction starts or when a button is pressed The display switches...

Страница 7: ...wait 10 seconds until the partial screen I displayed displays 5 digits no decimal place settable at maximum 65000 litres Such number identifies the minimum stock in the tank under which the meter will display the alarm To set this alarm level go to Alert screens and press button Value on display will start blinking and will be then modifiable increasing the value pressing button or decreasing it p...

Страница 8: ...ering a different fluid after dis assembly at different temperature or after signifi cant wear A proving container or a container of KNOWN volume will be needed for the calibration procedure It is recommended that the container volume be at least 19 liters 5 gallons 18 16 14 12 16 18 5 ATTENTON the system does not allow a cali bration if quantity transferred is under 5 litres Calibration procedure...

Страница 9: ...aragraph 3 5 3 Selecting unit of measure 2 Once the choice of custom has been confir med pressing button the meter will propose the default value blinking 0 100 3 Increase or decrease this value with and button until you reach the desired value taking into account that reference unit is the litre 4 Once the correct value is displayed wait 10 seconds the meter will save the value and return to Part...

Страница 10: ...in history visualize first transaction in history visualize total of first two transactions in history visualize total of first three transactions in history visualize total of first four transactions in history visualize total of all transactions in history visualize total Total visualize period total totPer reset period total totPer visualize the Stock situation modify the value in Stock visuali...

Страница 11: ...display brightness will be low It will be necessary to change batteries 4 2 CLEANING THE TURBINE The meter has 2 magnets fitted into the turbine This magnets could attract metallic powders if present that could block the turbine into the meter body For that reason it could be necessary to pe riodically verify and eventually clean the magnets To do this unscrew the internal shaft and its bolt Take ...

Страница 12: ...erify thanks to the arrow on the meter that it i correctly fitted on the line 3 contact your supplier to get an Exchange board 4 rotate the turbine by 180 1 change batteries 2 verify batteries positioning 1 verify technical data on pump flow rate 2 calibrate 3 verify that pump is not sucking air 4 clean magnets 4 3 STOCK If the meter has to be positioned in stock for a while clean it carefully Thi...

Страница 13: ...4 3 Meter cover tf035 1 4 Electronic PCB tf046 1 5 Screws m3 vt010 1 6 Battery AAA tf048 2 7 O ring or018 1 8 Body Diflow inline tf036 1 9 Turbine shaft tf039 1 10 Turbine holder tf038 2 11 Turbine tf037 1 12 Magnet tf040 2 13 Self blocking bolt vt009 1 14 Screw m3 x 12 vt011 1 DI FLOW IN LINE ADAM PUMPS 12 ...

Отзывы: