Страница 2: ...pment Co Ltd 2018 Easy Reference Model name of the balance Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase and Address Name and address of the supplier ...
Страница 3: ...ESCRIPTIONS 8 4 0 OPERATION 10 4 1 ZEROING THE DISPLAY 10 4 2 TARING 10 4 3 DETERMINING VALUE OF A PRODUCT BY WEIGHT 11 4 4 USING A STORED PLU VALUE FOR UNIT PRICE 11 4 5 ENTERING VALUES FOR THE PLUs 12 4 6 AUTO CLEAR KEY 13 4 7 PRICE PER KILOGRAM AND PER 100 GRAM Kg 100g KEY 13 4 8 AUTO SLEEP FUNCTION 13 4 9 BACKLIGHT OPERATION 14 To set the backlight 14 Backlight operation 14 4 10 RS 232 INTERFA...
Страница 4: ...URE Error Bookmark not defined 7 0 REPLACEMENT PARTS AND ACCESSORIES 19 WARRANTY STATEMENT 20 WARNING Please read carefully following instructions for installation and use before starting your work with a new balance Failure to use the balance in accordance with the advice in the user manual could mean that the product gives incorrect readings ...
Страница 5: ...e 3 x 6 digits backlit liquid crystal displays LCD Displays for Weight Unit Price and Total Price or Price to Pay Displays on both front and back panels Optional user display on pillar Price per 100g and per kilogram Not applicable for South Africa and Far East Auto sleep function Auto clear function Real Time Clock RTC and date RS 232 bi directional interface Battery operated for portability 90 h...
Страница 6: ...erature 10ºC to 40ºC Battery life 90 hours typical Battery Life is less when the backlight is used Power Mains power supply to an internal transformer Interface RS 232 bi directional interface English German French Spanish selectable text Date Time Real Time Clock RTC To print date and time information Dates in year month day day month year or month day year formats Battery backed Display 3 x 6 di...
Страница 7: ...al Battery Life is less when the backlight is used Power Mains power supply to an internal transformer Interface RS 232 bi directional interface English German French Spanish selectable text Date Time Real Time Clock RTC To print date and time information Dates in year month day day month year or month day year formats Battery backed Display 3 x 6 digits backlit LCD displays Housing ABS Plastic wi...
Страница 8: ...rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditio...
Страница 9: ...the spirit level bubble is in the centre of the level and the scale is supported by all four feet 6 Turn the power ON by pressing the power button on the keypad 7 The unit will display the software revision number in the Weight window and count down to zero while performing a self test 8 When ready all three displays will show zero 2 3 DISPLAY WINDOWS The window for the Weight has arrows to indica...
Страница 10: ...play To charge the battery simply switch the main power ON The scale need not be turned on The battery can operate for up to 90 hours when fully charged or less if the backlight is on The battery should be charged for 12 hours for full capacity If the battery icon is empty the scale will still operate for about 15 minutes after which it will automatically switch off to protect the battery from get...
Страница 11: ...nit weight from the unit price value Total The total key provides the total price to pay by multiplying unit weight by the unit price value MR The memory key shows the 2 most frequently used Weight Unit Price and Price to Pay values Setup Brings up the setup menu for changing date time power etc Zero or key It sets the zero when the platform is empty and no tare value is entered Auto Clear Allows ...
Страница 12: ...rm is empty 4 2 TARING Taring is used to eliminate the weight of a container so that only the net weight is displayed Steps 1 Zero the scale by pressing Zero 0 Esc if necessary The zero indicator will be on 2 Place an empty container on the platform The weight of the container will be displayed 3 Press Tare to zero the scale The displayed weight is then stored as the tare value and that value is s...
Страница 13: ... 5 00 6 50 Press the kg 100g key to change the calculation to a price based on the cost per 100g or the cost per kilogram If a different unit price is required either press CE to reset the unit price to 0 00 or simply enter a new unit price NOTE For South Africa and Far East unit weight per 100g or per kg is not available 4 4 USING A STORED PLU VALUE FOR UNIT PRICE Product Look Up PLU numbers are ...
Страница 14: ...r For example Press PLU Press 1 and then 4 immediately Display will show LOAd PoS 14 and then the PLU value for PLU 14 will be displayed If the item is loaded on the pan the Total Price window will show the total cost If nothing is loaded only the PLU value saved for the location will be displayed in the Unit Price window and the Total Price window will display 0 00 4 5 ENTERING VALUES FOR THE PLU...
Страница 15: ... Pressing it will turn the function to on again 4 7 PRICE PER KILOGRAM AND PER 100 GRAM Kg 100g KEY Pressing the kg 100g key will change the scale from using a price per kilogram to price per 100g This will show on the display This information is also saved for the PLU values that are stored in the memory NOTE This is not applicable for SWZ for South Africa and Far East 4 8 AUTO SLEEP FUNCTION If ...
Страница 16: ...n use the digits 1 or 6 to scroll through until BK is displayed Press the tare key to select The price to pay display will provide options for on off or auto Press the Tare key to select the preferred mode Backlight operation When the backlight is set to automatic control it will only turn on when the scale is being used when there is weight on the platform or when a key is pressed It will turn of...
Страница 17: ...cale can be controlled with the following commands The commands must be sent in upper case letters T cr lf Tares the scale to display the net weight This is the same as pressing Tare key Z cr If Sets the zero point for all subsequent weighing The display shows zero P cr lf Prints the results to a PC or printer using the RS 232 interface 4 10 2 RS 232 Setup The RS 232 interface uses parameters set ...
Страница 18: ...00 2400 4800 9600 or 19200 Set baud rate LAbEL 1 1 2 or 3 Select label format to print CoUntr Y E EnGLiSH EnGLiSH FrEnCH GErMAn or SPAniSH Select Language to be printed StErLi nG EUroPE dOLLAr StErLinG Select currency Euro Dollar or Pounds Sterling LABEL FORMATS NOTE All lines are terminated with a cr lf Label 1 English with shown 2017 08 31 13 01 56 UNIT PRICE NET TOTAL 1 20 100g 0 200kg 2 40 Lab...
Страница 19: ... the setup menu 2 Using the digits 1 and 6 scroll through until you see Time in the display Press the Tare key 3 The display below will show the current time set in the format 00 00 00 4 Use the keypad to enter the correct time in in hours minutes and seconds 24 hour format and press the Tare key to confirm Date To change the date follow the same process as above selecting date from the setup menu...
Страница 20: ... time i e 26 hours Err 2 Date input error Tried to set an illegal date i e 36th day Err 4 Initial Zero is greater than allowed typically 4 of the maximum capacity when power is turned on or when Zero is pressed Weight is on the pan when turning the scale on Excessive weight on the pan when zeroing scale Improper calibration of the scale Damaged load cell Damaged Electronics Err 6 A D count is not ...
Страница 21: ...EPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories contact your supplier or Adam Equipment A partial list of such items is as follows Main Power cord In use cover Replacement Battery Stainless Steel Pan ...
Страница 22: ...e faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable battery that is designed to be removed and replaced by the user Adam Equipment warrants that it will provide a replacement battery if the battery manifests a defect in materials or workmanship during the...
Страница 23: ... commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAL...
Страница 24: ...lated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which m...