EN
© 2016 Adam Equipment Co. Ltd.
1
3026612923-Rev1.00-Mar16
1.
SPECIFICATIONS
MODEL
MAXIMUM CAPACITY x WEIGHING DIVISIONS
Minimum
Weight
Range 1
Range 2
RAV 3D
1.5 kg x 0.5 g
3 kg x 1 g
10 g
RAV 6D
3 kg x 1 g
6 kg x 2 g
20 g
RAV 15D
6 kg x 2 g
15 kg x 5 g
40 g
RAV 30D
15 kg x 5 g
30 kg x 10 g
100 g
RAV 6Da
3 lb x 0.001 lb
6 lb x 0.002 lb
0.02 lb
RAV 15Da
6 lb x 0.002 lb
15 lb x 0.005 lb
0.04 lb
RAV 30Da
15 lb x 0.005 lb
30 lb x 0.01 lb
0.1 lb
RAV 60Da
30 lb x 0.01 lb
60 lb x 0.02 lb
0.2 lb
(NOTE: The scales automatically switch from Range 1 to Range 2 when weight
is increasing. Load must return to 0 before automatically switching back to R1
again. The indicator mark next to R1 or R2 on the front and rear display panels
shows which range the scale is currently operating in).
2. POWER SUPPLY
100-240 VAC 50/60 Hz 0.35A max. to 12 VDC 1000 mA external power supply.
6V 4Ah SLA rechargeable battery - insert into the battery holder on scale base.
Power consumption is approx. 29mA at standby, 67mA with backlight on.
Battery life without backlight is approx. 140 hrs.
To set backlight mode, press
‘
Tare
’
and
‘
4
’
key together. Press
‘
0
’
to turn off,
‘
1
’
for auto mode. Press
‘
M+
’
to apply the selected value, and return to
weighing, or
‘
CE
’
to escape without change.
3. OPERATION