background image

 

© Adam Equipment Company 2009 

 

 

ADAM  EQUIPMENT

  is  an  ISO  9001:2000  certified  global  organisation  with  more  than  30 

years experience in the production and sale of electronic weighing equipment. Products are 
sold through a world wide distributor network supported from our company locations in the 
UK, USA, SOUTH AFRICA and AUSTRALIA.  
 
 

ADAM

’s products are predominantly designed for the Laboratory, Educational, Medical and 

Industrial Segments. The product range is as follows: 
 

-Analytical and Precision Laboratory Balances 
-Counting Scales for Industrial and Warehouse applications 
-Digital Weighing/Check-weighing Scales 
-High performance Platform Scales with extensive software  
 features including parts counting, percent weighing etc. 
-Crane scales for heavy-duty industrial weighing 
-Digital Electronic Scales for Medical use 
-Retail Scales for Price computing 

 
 
 

 

 

 

© Copyright by Adam Equipment Co. Ltd.  All rights reserved.  No part of this 

publication may be reprinted or translated in any form or by any means without the 

prior permission of Adam Equipment. 

 

Adam Equipment reserves the right to make changes to the technology, features, 

specifications and design of the equipment without notice. 

 

All information contained within this publication is to the best of our knowledge 

timely, complete and accurate when issued.  However, we are not responsible for 

misinterpretations which may result from the reading of this material. 

 

The latest version of this publication can be found on our Website. 

 

Visit us at 

www.adamequipment.com 

 

 
 

 

Adam Equipment Co. Ltd

Bond Avenue 

Milton Keynes 

MK1 1SW 

UK 

 

Tel:+44 (0)1908 274545 

Fax: +44 (0)1908 641339 

 

E-mail: 

[email protected] 

 

Adam Equipment Inc. 

26, Commerce Drive 

Danbury, CT 

06810 

USA 

 

Tel: +1 203 790 4774 

Fax:  +1 203 792 3406 

 

E-mail: 

[email protected] 

 

Adam Equipment S.A. (Pty) Ltd. 

7 Megawatt Road,  

Spartan EXT 22, Kempton Park,  

Johannesburg 

Republic of South Africa 

 

Tel: +27 (0)11 974 9745 

Fax: +27 (0)11 392 2587 

 

E-mail: 

[email protected] 

 
 

 

Adam Equipment (S.E. ASIA) 

Pty Ltd.

 

2/71 Tacoma Circuit  

Canning Vale,  Perth  

WA 6155, Australia 

 

Tel: +61 (0) 8 6461 6236 

Fax: +61 (0) 8 9456 4462 

 

E-mail: 

[email protected] 

 

Содержание CBC SERIES

Страница 1: ...Adam Equipment Company 2009 Adam Equipment CBC SERIES P N 8680 Revision C4 February 2009 Software rev 3 06 above...

Страница 2: ...Adam Equipment Company 2009...

Страница 3: ...ARTS COUNTING 10 6 3 1 Setting Unit Weight 10 6 3 2 Counting more parts 11 6 3 3 Automatic part weight updates 11 6 3 4 Check counting 12 6 3 5 Manually Accumulated Totals 12 6 3 6 Automatic Accumulat...

Страница 4: ...Adam Equipment Company 2009 2...

Страница 5: ...5 models in each type with capacities up to 48 kg 100lb The scales have stainless steel weighing platforms on an ABS base assembly All scales are supplied with a RS 232 bi directional interface and re...

Страница 6: ...CBC 16a UNITS OF MEASURE MAXIMUM CAPACITY TARE RANGE READABILITY REPEATIBILITY LINEARITY Kilograms 8 0000 kg 8 kg 0 0002 kg 0 0002 kg 0 0004 kg Pounds 16 0000 lb 9 9995 E E lb 0 0005 lb 0 0005 lb 0 00...

Страница 7: ...nce Housing ABS Plastic Stainless Steel platform Pan Size 225 x 275mm 8 9 x 10 8 Overall Dimensions wxdxh 315 x 355 x 110mm 12 4 x 14 x 4 3 Net Weight 4 1 kg 9 lb Applications Counting Scales Function...

Страница 8: ...water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditioning vents Keep the scales clean Do not stack mat...

Страница 9: ...the displayed values when Auto print is switched off MR To recall the accumulated memory Pst To set the upper limit for the number of items counted When this upper limit is exceeded the scale will sou...

Страница 10: ...2 UNIT WEIGHT DISPLAY This display will show the unit weight of a sample This value is either input by the user or computed by the scale The unit of measurement is grams on CBC and pounds on CBCa sca...

Страница 11: ...1 ZEROING THE DISPLAY You can press the Zero key at any time to set the zero point from which all other weighing and counting is measured This will usually be necessary only when the platform is empt...

Страница 12: ...inputting a known unit weight using the keypad A Weighing a sample to determine the Unit Weight To determine the average weight of the items to be counted you will need to place a known quantity of th...

Страница 13: ...cale can be tared to account for the container weight as discussed in the earlier section After the scale is tared the items to be counted are added and the Count display will show the number of items...

Страница 14: ...nd count shown on the display can be added to the values in the memory by pressing the M key The Weight display will show the total weight the Count display will show the total accumulated count and t...

Страница 15: ...applications You need to enter a secure menu by entering a password when requested Press Tare once during the initial counting of the display after the power is turned on The Weight display will show...

Страница 16: ...ill return to the menu Record the new password in a secured place To exit a parameter press the Zero key 8 0 CALIBRATION The CBC scales are calibrated using metric weights and CBCa scales are calibrat...

Страница 17: ...displayed then repeat the process Suggested Calibration weights for CBC Series CBC 4 CBC 8a CBC 8 CBC 16a CBC 16 CBC 35a CBC 32 CBC 70a CBC 48 CBC 100a 2 kg 5 Ib 4 kg 10 lb 10 kg 30 lb 20 kg 50 lb 30...

Страница 18: ...hat is current RS 232 output of weighing data ASCII code Adjustable Baud rate 600 1200 2400 4800 9600 and 19200 baud 8 data bits No Parity 9 pin D subminiature socket Pin 3 Output Pin 2 Input Pin 5 Si...

Страница 19: ...mands must be sent in upper case letters i e T not t Press the Enter key of the PC after each command T cr lf Tares the scale to display the net weight This is the same as pressing Tare key Z cr If Se...

Страница 20: ...s will guide you through the parameter selected and the options available The parameters and their functions are Displays Weight Unit Weight Count Options Functions Port on On oFF Enable or disable th...

Страница 21: ...cumulate automatically when stable Print key no function Print continuously and accumulate when M is pressed Print key no function Print continuously M and Print key have no function 9 3 REAL TIME CLO...

Страница 22: ...te Err 2 is not the permissible values For example 34th day of a month is an invalid entry 9 4 AUTO SLEEP FUNCTION This function may be enabled or disabled by the user If enabled when the scale is not...

Страница 23: ...s for full capacity Just under the Count display is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is...

Страница 24: ...at the step that caused the message turning the balance on carry out the calibration or other functions If the error message is still shown contact your dealer for further support ERROR CODE DESCRIPTI...

Страница 25: ...uld be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should...

Страница 26: ...equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equi...

Страница 27: ...n a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with t...

Страница 28: ...ted in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment w...

Отзывы: