background image

 

© Adam Equipment Company 2009 

11 

by  re-calculating  it.  To  lock  the  Unit  Weight  and  avoid  re-
sampling, press 

[U. Wt./Units]

 

  If the scale is not stable, the calculation will not be completed. If 

the  weight  is  below  zero,  the  “

Count

”  display  will  show  negative 

count. 

 
B.  Entering a known Unit Weight 

 

  If the unit weight is already known then it is possible to enter that 

value using the keypad.  

 

 

  Enter  the  value  of  the  unit  weight  in  grams,  using  the  numeric 

keys  followed  by  pressing  the 

[U.  Wt./Units] 

key.  The  "

Unit 

Weight

" display will show the value as it was entered.  

 

  The  sample  is  then  added  to  the  scale  and  the  weight  will  be 

displayed as well as the quantity, based on the unit weight. 

6.3.2 Counting more parts 

 

  After  the  unit  weight  has  been  determined  or  entered,  it  is 

possible  to  use  the  scale  for  parts  counting.  The  scale  can  be 
tared  to  account  for  the  container  weight  as  discussed  in  the 
earlier section.  

 

  After the scale is tared the items to be counted are added and the 

"

Count

"  display  will  show  the  number  of  items,  computed  using 

the total weight and the unit weight. 

 

  It  is  possible  to  increase  the  accuracy  of  the  unit  weight  at  any 

time during the counting process by entering the count displayed 
and  then  pressing  the 

[Smpl]

  key.  You  must  be  certain  that  the 

quantity  displayed  matches  the  quantity  on  the  scale  before 
pressing the key. The unit weight can be adjusted based upon a 
larger  sample  quantity.  This  will  give  greater  accuracy  when 
counting larger sample sizes. 

6.3.3 Automatic part weight updates 

 

  At the time of computing the unit weight (see section 6.3.1A), the 

scale  will  automatically  update  the  unit  weight  when  a  sample 
less than the sample already on the platform is added. A beep will 
be  heard  when  the  value  is  updated.  It  is  wise  to  check  the 
quantity  is  correct  when  the  unit  weight  has  been  updated 

Содержание CBC SERIES

Страница 1: ...Adam Equipment Company 2009 Adam Equipment CBC SERIES P N 8680 Revision C4 February 2009 Software rev 3 06 above...

Страница 2: ...Adam Equipment Company 2009...

Страница 3: ...ARTS COUNTING 10 6 3 1 Setting Unit Weight 10 6 3 2 Counting more parts 11 6 3 3 Automatic part weight updates 11 6 3 4 Check counting 12 6 3 5 Manually Accumulated Totals 12 6 3 6 Automatic Accumulat...

Страница 4: ...Adam Equipment Company 2009 2...

Страница 5: ...5 models in each type with capacities up to 48 kg 100lb The scales have stainless steel weighing platforms on an ABS base assembly All scales are supplied with a RS 232 bi directional interface and re...

Страница 6: ...CBC 16a UNITS OF MEASURE MAXIMUM CAPACITY TARE RANGE READABILITY REPEATIBILITY LINEARITY Kilograms 8 0000 kg 8 kg 0 0002 kg 0 0002 kg 0 0004 kg Pounds 16 0000 lb 9 9995 E E lb 0 0005 lb 0 0005 lb 0 00...

Страница 7: ...nce Housing ABS Plastic Stainless Steel platform Pan Size 225 x 275mm 8 9 x 10 8 Overall Dimensions wxdxh 315 x 355 x 110mm 12 4 x 14 x 4 3 Net Weight 4 1 kg 9 lb Applications Counting Scales Function...

Страница 8: ...water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditioning vents Keep the scales clean Do not stack mat...

Страница 9: ...the displayed values when Auto print is switched off MR To recall the accumulated memory Pst To set the upper limit for the number of items counted When this upper limit is exceeded the scale will sou...

Страница 10: ...2 UNIT WEIGHT DISPLAY This display will show the unit weight of a sample This value is either input by the user or computed by the scale The unit of measurement is grams on CBC and pounds on CBCa sca...

Страница 11: ...1 ZEROING THE DISPLAY You can press the Zero key at any time to set the zero point from which all other weighing and counting is measured This will usually be necessary only when the platform is empt...

Страница 12: ...inputting a known unit weight using the keypad A Weighing a sample to determine the Unit Weight To determine the average weight of the items to be counted you will need to place a known quantity of th...

Страница 13: ...cale can be tared to account for the container weight as discussed in the earlier section After the scale is tared the items to be counted are added and the Count display will show the number of items...

Страница 14: ...nd count shown on the display can be added to the values in the memory by pressing the M key The Weight display will show the total weight the Count display will show the total accumulated count and t...

Страница 15: ...applications You need to enter a secure menu by entering a password when requested Press Tare once during the initial counting of the display after the power is turned on The Weight display will show...

Страница 16: ...ill return to the menu Record the new password in a secured place To exit a parameter press the Zero key 8 0 CALIBRATION The CBC scales are calibrated using metric weights and CBCa scales are calibrat...

Страница 17: ...displayed then repeat the process Suggested Calibration weights for CBC Series CBC 4 CBC 8a CBC 8 CBC 16a CBC 16 CBC 35a CBC 32 CBC 70a CBC 48 CBC 100a 2 kg 5 Ib 4 kg 10 lb 10 kg 30 lb 20 kg 50 lb 30...

Страница 18: ...hat is current RS 232 output of weighing data ASCII code Adjustable Baud rate 600 1200 2400 4800 9600 and 19200 baud 8 data bits No Parity 9 pin D subminiature socket Pin 3 Output Pin 2 Input Pin 5 Si...

Страница 19: ...mands must be sent in upper case letters i e T not t Press the Enter key of the PC after each command T cr lf Tares the scale to display the net weight This is the same as pressing Tare key Z cr If Se...

Страница 20: ...s will guide you through the parameter selected and the options available The parameters and their functions are Displays Weight Unit Weight Count Options Functions Port on On oFF Enable or disable th...

Страница 21: ...cumulate automatically when stable Print key no function Print continuously and accumulate when M is pressed Print key no function Print continuously M and Print key have no function 9 3 REAL TIME CLO...

Страница 22: ...te Err 2 is not the permissible values For example 34th day of a month is an invalid entry 9 4 AUTO SLEEP FUNCTION This function may be enabled or disabled by the user If enabled when the scale is not...

Страница 23: ...s for full capacity Just under the Count display is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is...

Страница 24: ...at the step that caused the message turning the balance on carry out the calibration or other functions If the error message is still shown contact your dealer for further support ERROR CODE DESCRIPTI...

Страница 25: ...uld be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should...

Страница 26: ...equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equi...

Страница 27: ...n a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with t...

Страница 28: ...ted in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment w...