background image

 

© Adam Equipment Company 2007 

 

 

Adam Equipment 

 

 
 
 

 

   CBC-M SERIES 

with EC type Approval 

(P.N. 8226,

 

Revision C6, February 2008) 

  

 
 
 

 

Software rev.: 3.06A & above 

 

 

 
 
 
 
 
 

 

 

Содержание CBC 15M CBC 30M

Страница 1: ... Adam Equipment Company 2007 Adam Equipment CBC M SERIES with EC type Approval P N 8226 Revision C6 February 2008 Software rev 3 06A above ...

Страница 2: ... Adam Equipment Company 2007 ...

Страница 3: ...eight 8 6 3 2 Counting more parts 9 6 3 3 Automatic part weight updates 10 6 3 4 Check counting 10 6 3 5 Manually Accumulated Totals 10 6 3 6 Automatic Accumulated Totals 11 7 0 PARAMETERS 11 8 0 RS 232 INTERFACE 11 8 1 INPUT COMMANDS FORMAT 13 8 2 RS 232 SETUP 14 8 3 REAL TIME CLOCK SETUP 15 8 4 AUTO SLEEP FUNCTION 15 9 0 BATTERY AND BACKLIGHT OPERATION 16 9 1 BATTERY 16 9 2 BACKLIGHT FOR LCD 17 ...

Страница 4: ...atforms on an ABS base assembly All scales are supplied with a RS 232 bi directional interface and real time clock RTC All scales have sealed keypad with colour coded membrane switches and there are three large easy to read liquid crystal type displays LCD The LCD s are supplied with a backlight The scales include automatic zero tracking audible alarm for pre set weights automatic tare accumulatio...

Страница 5: ...tery 90 hours operation Calibration Only allowed if the seals are broken Display 3 x 6 digits LCD digital displays Balance Housing ABS Plastic Stainless Steel platform Pan Size 225 x 275mm 8 9 x 10 8 Overall Dimensions wxdxh 315 x 355 x 110mm 12 4 x 14 x 4 3 Net Weight 4 1 kg 9 lb Applications Counting Scales Functions Parts counting weighing accumulating memory Check count with alarm Interface RS...

Страница 6: ...rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditio...

Страница 7: ...e scale will show the current software revision number in the Weight display window V3 06A where 3 06 indicates the current software revision number and A indicates that it is the approved model Next a self test is performed At the end of the self test it will display 0 in all three displays if the zero condition has been achieved 4 0 KEY DESCRIPTIONS Keys Functions 0 9 Numeric entry keys used to ...

Страница 8: ...t in memory as a tare value subtracts the tare value from the weight and shows the results This is the net weight Entering a value using the keypad will store that as the tare value Zero Sets the zero point for all subsequent weighing It shows zero 5 0 DISPLAYS The scales have three digital display windows These are Weight Unit Weight and Count 5 1 WEIGHT DISPLAY It has 5 digit display to indicate...

Страница 9: ... stored the Preset or symbol as above will have an arrow above 5 3 COUNT DISPLAY This display will show the number of items on the scale or the value of the accumulated count See the next section on OPERATION The arrow indicator will be seen above Memory when a value has been entered into the memory 6 0 OPERATION 6 1 ZEROING THE DISPLAY You can press the Zero key at any time to set the zero point ...

Страница 10: ...ducts those were removed The indicator above Zero will also be ON because the platform is back to the same condition as it was when the Zero key was pressed last 6 3 PARTS COUNTING 6 3 1 Setting Unit Weight In order to do parts counting it is necessary to know the average weight of the items to be counted This can be done by weighing a known number of the items and letting the scale determine the ...

Страница 11: ... the Count display will show negative count B Entering a known Unit Weight If the unit weight is already known then it is possible to enter that value using the keypad Enter the value of the unit weight in grams using the numeric keys followed by pressing the U Wt Units key The Unit Weight display will show the value as it was entered The sample is then added to the scale and the weight will be di...

Страница 12: ...3 4 Check counting Check counting is a procedure to cause an alarm to sound when the number of items counted on the scale meets or exceeds a number stored in the memory by using the Pst key The stored value is entered from the keyboard Enter the numeric value to be stored using the numeric keys Then press the Pst key to store the value To clear the value from the memory and thereby turn off the ch...

Страница 13: ... not be stored when the scale returns to zero See the Section 8 0 on RS 232 Interface for details on how to enable Automatic Accumulation 7 0 PARAMETERS The parameters are set to customise the scale to suit the weighing applications For CBC M scales it is necessary to enter a secure menu using a password to set some parameters To proceed with the setting of these parameters the security seal has t...

Страница 14: ...nuous print is turned on The continuous print will only be for weight and display data that is current Net 1 234 Kg U W 123 g PCS 10 pcs lf Includes 2 line feeds lf 9 pin d subminiature socket Pin 3 Output Pin 2 Input Pin 5 Signal Ground Date 12 09 2006 Time 14 56 27 lf cr Net Wt 1 234 Kg UnitWt 123 g PCS 10 pcs lf cr Includes 2 line feeds with carriage return lf cr Date 12 09 2006 Time 14 56 27 l...

Страница 15: ...er case letters i e T not t Press the Enter key of the PC after each command T cr lf Tares the scale to display the net weight This is the same as pressing Tare key Z cr If Sets the zero point for all subsequent weighing The display shows zero P cr lf Prints the results to a PC or printer using the RS 232 interface It also adds the value to the accumulation memory if the accumulation function is n...

Страница 16: ... for continuous out print manually or printing automatically AC mAn AC mAn AC Auto or AC oFF Select the operation of the accumulation method manually automatically or turned off CoUntr Y E nGLiSH EnGLiSH FrEnCH GErMAn or SPAniSH Select Language to be printed Scale will do the following depending on the Accumulation and Print settings ACCUMULATION FUNCTIONS PRINT FUNCTIONS AC Auto AC mAn AC oFF Pri...

Страница 17: ...eys using a 24 hour clock format 3 41PM is 154100 Press the Tare key to accept the time The display will show the current date format Press the Print key to change the date format Available formats are Y m d year month day m d Y month day year d m Y day month year Press the Tare key to accept the chosen format and then enter the date in this format Press the Tare key to accept the date An error co...

Страница 18: ... The scale will still operate for about 10 minutes after which it will automatically switch off to protect the battery To charge the battery simply plug the scale into the mains and switch the mains power ON The scale does not need to be turned on The battery should be charged for at least 12 hours for full capacity Just under the Count display is an LED to indicate the status of battery charging ...

Страница 19: ...ng or during operation the scale may show an error message The meaning of the error messages is described below If an error message is shown repeat the step that caused the message turning the balance on carry out the calibration or other functions If the error message is still shown contact your dealer for further support ERROR CODE DESCRIPTION POSSIBLE CAUSES Err 1 Time input error Tried to set ...

Страница 20: ...Y MAKE IT ILLEGAL TO USE THE SCALES FOR SALES OF GOODS CONTACT YOUR TRADING STANDARDS OFFICE FOR FURTHER ASSISTANCE 11 2 SECURITY SEALS To seal the scale a lead wire seal can be used as shown below The base has a metal pin that protrudes through the cover The security seal may be threaded through this metal pin making it impossible to remove the cover without damaging either the security seal or t...

Страница 21: ...uld be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale C...

Страница 22: ...nstallation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual Repairs carried out under the warranty does not extend the warranty period Components removed during the warranty repairs become the company property The statutory right of the purchaser is not affected by this warranty The terms of this warranty is gov...

Страница 23: ...ow Voltage Directive 73 23 EWG Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen Niederspannungsrichtlinie 73 23 CEE Matériel électrique pour utilisation dans des limites de tension définies Directive Basse Tension 89 336 EEC Electromagnetic compatibility 89 336 EWG Elektromagnetische Verträglichkeit 89 336 CEE Compatibilité électromagnétique Fabrikant Adam Equipment ...

Страница 24: ...erial The latest version of this publication can be found on our Website www adamequipment com ADAM EQUIPMENT is an ISO 9001 2000 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Medical retail and Industrial Segments The product range can be described as f...

Отзывы: