background image

          Operating manual

               Optical level

ADA Ruber-Х32

Manufacturer

Address

RUBER

 - X32

Содержание Ruber-X32

Страница 1: ...Operating manual Optical level ADA Ruber 32 Manufacturer Address RUBER X32...

Страница 2: ...6 5 Prepararion before starting to work 6 5 1 Set up the instrument 6 5 2 Focusing and surveying 8 5 3 Circular level 8 5 4 Automatic compensator 9 5 5 Reticule 10 6 The action of the instrument 11 6...

Страница 3: ...hen the instrument is adjusted with circular level mechanism of automatic compensation fixes the line of sight into the horizon This instrument is designed to provide stable nwork notwithstanding envi...

Страница 4: ...S 8 Horizontal Knob 9 Objective Lens 10 Horizontal Circle Index 11 Eyepiece 12 Reticle Adjusting Screw Cover 13 Peep sight 14 Compensator locking button 1 Reflector 2 Circular level 3 Circular level A...

Страница 5: ...h stadia plumb SPECIFICATIONS ADA Ruber 32 Magnification 32 x Standard error 1 5 mm Objective diameter 36 mm Min focusing distance 1 m Compensator working range 15 Compensator error 0 3 1 Compensator...

Страница 6: ...To avoid moisture condensation inside the instrument dry out the case and the instrument Check regularly instrument adjustment Keep the lens clean and dry To clean the lens use soft cotton cloth Neve...

Страница 7: ...ent on the tripod Pic 3 6 When you use the tripod with spherical head loosen slightly retaining bolt Holding with both hands the instrument with support 6 move the instru ment along the tripod head to...

Страница 8: ...ument at the staff with the help of front sight 13 Then with rotation of the knob 4 place the staff in the center of eyesight Remove parallax between the staff and reticule while rotating rack and pin...

Страница 9: ...s till the bubble shift will remove completely Pic 7 Pic 8 5 4 AUTOMATIC COMPENSATOR 1 Make the bubble into the center of circular level 2 Point at clear object Then rotate leveling screw on 1 8 rotat...

Страница 10: ...uld twitch slightly and back to the previous place 5 5 RETICULE 1 Set up the instrument between A and B points Take readings a1 and b1 Pic 10 2 Set up the instrument at 2 m off the point A Take readin...

Страница 11: ...essary repeat the adjustment Note to remove skew of reticule loosen clamp screw turn the ocular 6 THE ACTION OF THE INSTRUMENT 6 1 DETERMINATION OF ELEVATION 1 Set up the instrument between the A and...

Страница 12: ...f 4 The difference a b is the elevation h point to A point Pic 13 Example H a b 1 735 m 1 224 m 0 511 m Thus B point is higher than A point on 0 511 Elevation value will be negative if B point is lowe...

Страница 13: ...etermine errors It s better to take measurements from A point to B point and back to A point In this case it is possible to compute locking error 6 2 THE MEASUREMENT OF HORIZONTAL ANGLE Horizontal cir...

Страница 14: ...two points 1 Point at the staff and calculate the number of centimeter division between two stadia hairs Pic 17 i 17 2 Value is equivalent to the distance in meters between the staff and the instrume...

Страница 15: ...house in perfect condition and adjustment the user is expected to carry out periodic checks of the product s accuracy and general performance The manufacturer or its representatives assumes no respons...

Страница 16: ...ducts or parts caused by misuse including without limitation misapplication or nrgligence of the terms of service instruction 6 Power supply units chargers accessories wearing parts 7 Products damaged...

Страница 17: ...clear filled stamp or mark of thr seller is obligatory Technical examination of instruments for fault identification which is under the warranty is made only in the authorized service center In no eve...

Страница 18: ...___________________ _____________ name and model of the instrument Corresponds to ______________________________________________________________ designation of standard and technical requirements Data...

Страница 19: ...ADA Ruber 32 RUBER X32...

Страница 20: ...Ruber x32 1 21 2 21 2 1 21 2 2 22 2 3 23 3 23 4 24 5 25 5 1 25 5 2 27 5 3 27 5 4 28 5 5 29 6 30 6 1 30 6 2 32 6 3 33 7 1 8 2 Ruber 32 RUBER X32...

Страница 21: ...21 RUBER X32 MEASUREMENT FOUNDATION 1 ADA Ruber 32 2 2 1 ADA Ruber 32 Ruber 32 Ruber x32...

Страница 22: ...22 RUBER X32 MEASUREMENT FOUNDATION 2 2 1 8 2 9 3 10 4 11 5 12 6 13 7 14 RUBER X32 1 2 3 4 6 12 11 14 10 13 7 8 5 9...

Страница 23: ...23 RUBER X32 MEASUREMENT FOUNDATION 2 3 ADA Ruber 32 32 x 1 1 5 mm 36 mm Min 1 m 15 0 3 1 0 5 8 2mm 360 1 2 1 kg 25 50 3...

Страница 24: ...24 RUBER X32 MEASUREMENT FOUNDATION 4 25 50...

Страница 25: ...25 RUBER X32 MEASUREMENT FOUNDATION 5 5 1 1 1 2 3 1...

Страница 26: ...26 RUBER X32 MEASUREMENT FOUNDATION 4 2 5 3 6 6 8 4 7 8 5 5 3 2 4 5...

Страница 27: ...27 RUBER X32 MEASUREMENT FOUNDATION 5 2 1 2 3 13 4 7 7 5 3 1 5 2 2 180 6 6...

Страница 28: ...28 RUBER X32 MEASUREMENT FOUNDATION 3 5 7 4 8 5 9 5 4 1 2 1 8 ADA Ruber x32 14...

Страница 29: ...29 RUBER X32 MEASUREMENT FOUNDATION 5 5 1 1 b1 10 2 2 2 b2 11 10 b2 a2 a1 b1 b2 b2 b2 b2 11...

Страница 30: ...30 RUBER X32 MEASUREMENT FOUNDATION 3 c 12 4 b2 b2 b2 b2 6 6 1 1 13 2...

Страница 31: ...31 RUBER X32 MEASUREMENT FOUNDATION 3 b 4 a b h 13 h a b 1 735 m 1 224 m 0 511 m 0 511 1 13 2...

Страница 32: ...32 RUBER X32 MEASUREMENT FOUNDATION 6 2 10 360 1 1 2 8 0 15 3 30 16 15 16...

Страница 33: ...33 RUBER X32 MEASUREMENT FOUNDATION 6 3 1 17 2 32 32 32 100 18 18 17...

Страница 34: ...34 RUBER X32 MEASUREMENT FOUNDATION 1...

Страница 35: ...1 2 3 4 5 6 7 8 9 WWW ADAINSTRUMENTS COM info adainstruments com...

Страница 36: ..._______________________________________________ ___________________ _________________ ___________________ 24 II 454 491 _________________________________...

Страница 37: ...___________________________ _____________________________________________________________________________ _______________ ______________________________________________________________________________...

Страница 38: ...ADA MEASUREMENT FOUNDATION WWW ADAINSTRUMENTS COM...

Отзывы: