MEASUREMENT FOUNDATION
12
ROTARY
500
HV
Servo
7. You can use the remote control to control the instrument (see Using the Remote Control).
8. To return to Automatic mode, press the Auto/Manual key. The Manual Indicator will turn off.
9. To turn the instrument off, press the Power key.
Plumb Down
The Plumb Down feature enables you to center the instrument onto a selected point. It is much easier to
use
this feature if you set up the instrument on a tripod with a hollow connecting bolt.
1. Set up the instrument on a tripod.
2. Move the tripod and instrument so that they are approximately above the selected point.
3. Level the instrument as in Horizontal Setup.
4. Press the Power key to turn the instrument.
5. Move the Plumb Down beam onto the selected point on the ground by raising and lowering the tripod
legs.
6. Level the instrument again, and adjust the Plumb Down beam with the tripod legs as in step 5.
7. Repeat step 6 until the Plumb Down beam is suficiently accurate for your purposes.
8. If you wish to transfer a point to the ceiling, use the Plumb Up beam once the instrument is accurately
centered.
Changing Rotation Speed
The laser beam is more visible when the rotating speed is slower. Change the speed of the rotating laser
head by pressing the Speed key. The default option is 600 rpm. Pressing the key moves a step forward in
the speed cycle (600-0-60-120-300-600-rpm).