6. Operating Instructions
To get the most out of your ROTARY 500 HV Servo, please adhere carefully to the following instructions.
NOTE: Avoid setting up the laser near heavy machinery or sources of vibration that may adversely
affect the leveling of the Laser.
Horizontal Plane (Automatic Mode)
Place the instrument on irm and dry ground or on a standard 5/8” tripod (not included) or ceiling to loor
leveling pole (not included) or wall mount accessory (not included).
1. Set up the instrument approximately level; the instrument can compensate for up to ±5° from the hori-
zontal plane.
2. Press the Power key. The Power Indicator will light up. If the instru ment is set up outside the ±5° limit the
Manual Indicator will blink, the laser beams with not be projected and rotation will not begin.
Please turn off the instrument and set up again.
3. Verify that the instrument is in automatic mode – the Manual Indicator must be unlit.
4. The instrument is ready for work when the Power Indicator is lit, the Manual Indicator has stopped blinking, and
the laser beams are projected. The instrument is now level and the laser head will rotate clockwise at 600 rpm.
5. To make the beam more visible, change the rotating speed using the speed key, or use the Laser Detector
to detect the laser beam (see Laser Detector).
6. Change the rotation direction by pressing the Clockwise Rotation or Counterclockwise Rotation key.