7
3. TECHNICAL MANUAL FOR THE APPLIANCE INSTALLER
The device may be connected to the electrical installation only by a qualified person.
Parts that have been secured by the manufacturer may not be adjusted by the installer.
The fryer is designed for 400 V AC power supply ant the 32 A amperage.
The fryer's electrical installation includes:
-
Electric theromstat (0 – 200
C)
-
Main switch,
-
overheating protection (temperature limiter - 220
C)
-
contactor
-
electric cables
-
external power cord with plug
-
protective grounding clamp
When installing devices, the following legal provisions must be observed:
-
Standards, regulations, building and fire regulations.
-
Health and safety regulations.
-
Standards, regulations, ordinances for the installation of electrical devices
-
Normy, przepisy, zarządzenia dotyczące wentylacji.
The appliance installer should:
-
Have a qualification certificate
-
Read the information on the type plate
-
Check the effectiveness of all components of the appliance's functioning.
-
Familiarize the user with the operation of the device
3.1. Asembly order
Before starting to assemble the fryer, make sure that all its parts are complete and have
not been damaged in transport.
Determining the location for the fryer is extremely important in terms of operating
range, speed and convenience.
1. Place the appliance in a place that allows easy access from all sides, on a hard and
non-flammable surface. The distance from non-flammable walls should be at least 10
cm. If the walls are not resistant to high temperatures, use appropriate insulation and
keep a minimum distance of 30 cm. Also keep a distance of at least 20 cm from other
devices.