background image

en

21

EN

FR

NL

ES

IT

DE

PL

RU

Smart Line SLE - SLE Plus 

: 661Y2100 • A

STARTING UP

Cold water

Hot water

Figure 1

1

3

3

2

Figure 2

1

2

4

3

1

2

Содержание Smart Line SLE 130

Страница 1: ...Smart Line SLE SLE Plus 661Y2100 A EN FR NL ES IT DE PL RU INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS SLE 130 160 210 240 300 SLE Plus 210 240 300 SMART Line ...

Страница 2: ...tions 8 Domestic hot water connections 8 Domestic hot water performances 9 Maximum operating conditions 9 Electrical characteristics 10 INSTALLATION 11 Package contents 11 Tools required for the installation 11 Safety instructions 12 Connection 14 Connection to the DHW circuit 15 Connection to the primary circuit 16 Examples of possible combinations of the SLE and SLE Plus 17 Tank used as electric...

Страница 3: ...LE OF CONTENTS STARTING UP 19 Safety instructions to fill the tank 19 Filling 20 Checks before starting up 22 Starting up 22 MAINTENANCE 23 Periodic checks by the user 23 Annual maintenance 23 Draining 24 Bringing back into service after maintenance 25 Fault finding 26 ...

Страница 4: ...lations applicable to installations Failure to follow the instructions in this manual could result in personal injury or a risk of environmental pollution The manufacturer declines all liability for any damage caused as a result of incorrect installation or in the event of the use of appliances or accessories that are not approved by the manufacturer Essential instructions for the correct operatio...

Страница 5: ...Key 1 Control thermostat 60 90 C to set the domestic hot water DHW temperature 2 Manual reset high limit thermostat to restart the tank after overheating of the primary circuit 3 Connection plug to connect the electrical power supply 4 Thermometer indicates the temperature of the DHW 4 1 3 2 ...

Страница 6: ...oor Possibility to heat by transfer fluid or independently with an optional electric resistance 1 Manual air bleed valve 2 Polypropylene shell 3 Dip tube 4 Electrical heating element optional 5 Outer steel tank primary circuit 6 Polypropylene top lid 7 Polyurethane foam insulation 8 Dry well 9 Stainless steel tank DHW 10 Polypropylene bottom lid 6 2 1 3 5 4 7 9 8 10 ...

Страница 7: ... 200 Primary fluid flow rate L h 2100 2600 3500 4200 5500 Primary pressure drop mbar 17 22 37 45 51 Tank heating surface m 1 03 1 26 1 54 1 94 2 29 Empty weight kg 45 54 66 76 87 DIMENSIONS SLE 130 SLE 160 SLE 210 SLE 240 SLE 300 SLE Plus 210 SLE Plus 240 SLE Plus 300 A mm 1025 1225 1495 1740 2045 1495 1740 2050 B mm 760 960 1230 1480 1780 1230 1480 1785 C mm 235 235 235 235 230 235 235 235 D mm 2...

Страница 8: ...E 130 160 5 Optional electrical heating element connection 6 Heating return connection heat pump 7 Flow heating circuit except SLE 130 160 8 Return heating circuit except SLE 130 160 1 Cold water inlet connection 2 Auxiliary connection DHW 3 Domestic hot water connection Connections dimensions SLE SLE Plus Heating connection Ø 1 F Optional electrical heating element connection Ø 1 F Connections di...

Страница 9: ...970 Peak flow 1st hour at 40 C T 30K L 60 784 1063 1349 1820 2360 60 C T 50K L 60 384 549 689 913 1100 Maximum absorbed power kW 23 31 39 53 68 Reheat time Minutes 22 22 20 20 22 Conditions Primary circuit temperature 85 C water intake temperature 10 C MAXIMUM OPERATING CONDITIONS Maximum Service Pressure tank full of water Primary circuit 3 bar DHW water circuit 8 6 bar Maximum Temperature Maximu...

Страница 10: ...rmostats The control thermostat of the tank can not control the heating element To be mounted with an external box with a switch and a circuit breaker not included in the delivery Volt Amp Power Code 1 x 230 V 13 3 kW 10800081 3 x 400 V N 4 4 3 kW 10800082 1 x 230 V 26 6 kW 10800083 3 x 400 V N 8 8 6 kW 10800084 Wiring diagram 1 Manual reset high limit thermostat 2 Control thermostat 60 90 C Bk Bl...

Страница 11: ...of damages Contents packaging A domestic hot water tank A technical manual TOOLS REQUIRED FOR THE INSTALLATION General remarks Make sure to place the rating plate on the outer casing of the tank so that it is easily accessible and readable The manufacturer reserves the right to change the technical characteristics and features of its products without prior notice The availability of certain models...

Страница 12: ...nsure easy access at all times To avoid any risk of corrosion connect the stainless steel tank directly to the earth Make sure to install a pressure reducing valve set at 4 5 bar in the DHW circuit if the supply pressure is higher than 6 bar On the DHW circuit install an approved safety group comprised of a safety valve set at 7 bar a check valve and a stop valve Make sure that the outlet of the s...

Страница 13: ... developing bacteria exists including Legionella pneumophila if a minimum temperature of 60 C is not maintained in both the DHW tank and the hot water distribution network Essential instructions for the electrical safety Only an approved installer is authorized to carry out the electrical connections Install a 2 way switch and a fuse or circuit breaker of the recommended rating outside the applian...

Страница 14: ...propriate size Make sure that the circuit between the tank and the safety valve is always open The third DHW tank connection if any can be used for the auxiliary DHW loop If the connection is not used replace the protective plug by a brass plug of the appropriate size General remarks In certain countries the domestic kits must be approved The circuit illustrations are basic principle diagrams only...

Страница 15: ...Thermostatic mixing valve 12 Air vent Cold water Hot water Domestic hot water kit option 1 Thermostatic mixing valve 2 Mixed water outlet Ø 3 4 M 3 DHW expansion vessel connection Ø 3 4 M 4 Safety unit 7 bar 5 Outlet hot water tank Ø 3 4 F 6 Inlet cold water tank Ø 3 4 F 7 Cold water inlet Ø 3 4 M 8 Drain connection Ø 1 M 2 7 1 5 6 3 4 8 The drain connection 8 must be connected to the sewer system...

Страница 16: ...NSTALLATION CONNECTION TO THE PRIMARY CIRCUIT 1 Primary circuit filling valve 2 Charging pump 3 Check valve 4 Primary circuit stop valve 5 Expansion vessel 6 Pressure gauge 7 Safety valve set at 3 bar 8 Drain valve 9 Stop valve Cold water Hot water 1 2 3 4 8 5 9 7 6 4 ...

Страница 17: ...rt Line SLE SLE Plus 661Y2100 A INSTALLATION EXAMPLES OF POSSIBLE COMBINATIONS OF THE SLE AND SLE PLUS SLE Plus combined with a heat pump and floor heating system SLE 210 240 300 combined with a boiler and floor heating system Prestige ...

Страница 18: ...k is not filled and bled 1 System filling valve 2 Safety valve set at 3 bar 3 Expansion vessel 4 Isolation valve heating system 5 Pressure gauge Essential instruction for the correct operation of the installation Connections must be carried out in accordance with applicable standards and regulations 4 1 2 3 5 Plug all unused connections Plug all unused connections ...

Страница 19: ...commended in the local regulations Consult the manufacturer to determine the compatibility of the antifreeze with the tank s construction materials Essential instructions for the correct operation of the installation Before bringing the tank into service check the connections to avoid any risk of leaks during filling Only use drinking water to check that the DHW tank is watertight The on site test...

Страница 20: ...g boiler 3 Open the air bleed valve 4 located on the top of the hot water tank 4 When the air is eliminated close the air bleed valve 4 Make sure the air bleed valve is tight FILLING Essential instructions for the correct operation of the installation TheDHWtankmustalwaysbefilledandpressurisedbeforefillingandpressurising the primary circuit 1 Check that the drain valve 3 of your primary circuit is...

Страница 21: ...en 21 EN FR NL ES IT DE PL RU Smart Line SLE SLE Plus 661Y2100 A STARTING UP Cold water Hot water Figure 1 1 3 3 2 Figure 2 1 2 4 3 1 2 ...

Страница 22: ...ected and not leaking Check that the sensor of the thermostat is correctly positioned in the dry well see figures below STARTING UP If the tank is used as electric DHW tank only 1 Put the electric plug into the mains socket 2 Adjust the required temperature using the control thermostat integrated in the electrical resistance If the tank is used within a heating installation To put the installation...

Страница 23: ... periodically it may be due to an expansion problem or clogging of the valve For internal inspections the hand hole can be used If there is none use one of the water connections to insert the appropriate inspection equipment If necessary drain the tank before inspection The annual maintenance service performed by an engineer must include A check of the air bleed valve the bleeding of air can lead ...

Страница 24: ...ary circuit of the hot water heater 1 Stop the charging pump 2 Isolate the hot water primary circuit by closing the stop valves 1 3 Connect the drain valve 2 to the sewer using a flexible hose 4 Open the drain valve 2 and drain the water from the primary circuit to the drain 5 Open the tank s air bleed valve 3 to accelerate drainage 6 Close the drain valve 2 and air bleed valve 3 after draining th...

Страница 25: ... Connect the drain valve 2 to the sewer using a flexible hose 4 Open the drain valve 2 and the air vent 5 to drain the water from the DHW tank to the sewer 5 Close the drain valve 2 and the air vent 5 after having drained the DHW tank en 25 EN FR NL ES IT DE PL RU Smart Line SLE SLE Plus 661Y2100 A MAINTENANCE BRINGING BACK INTO SERVICE AFTER MAINTENANCE Refer to chapter Starting up page 19 Figure...

Страница 26: ... boiler and the control thermostat of the tank 3 Check if the charging pump works properly and replace if necessary 4 Check the safety thermostat on the tank and or the electric heating element and reset or replace if necessary 5 Check the electric heating element and replace if necessary Models SLE SLE Plus SLE SLE Plus electric heating element FAULT FINDING What to do if the domestic hot water i...

Страница 27: ...rt Line SLE SLE Plus 661Y2100 A RATING PLATE Type Year N Art T max 99999 12345678 Name of product 2014 90 C 3 bar 230 V 50Hz 8 6 bar KERKPLEIN N 39 1601 RUISBROEK BELGIUM www acv com 21 99999 91 12345678 92 2014 Max Max N Ser SPECIMEN ...

Страница 28: ...EN FR NL ES IT DE PL RU en 28 Smart Line SLE SLE Plus 661Y2100 A ...