background image

1

INTENDED USERS OF THESE INSTRUCTIONS

These instructions are intended for
- specifying engineers
- installing engineers
- users
- servicing technicians

SYMBOLS

The following symbols are used in these instructions:

Essential instruction for operating the system
correctly.

Essential instruction for personal safety and
environmental protection.

APPLICABLE STANDARDS

The products have received the “EC” certificate in accordance with
the standards prevailing in different countries (European Directives
92/42/EEC, “efficiency”, 90/396/EEC “gas appliances”). These
products have also received the Belgian “HR+” (gas boilers) marks.

WARNINGS

These instructions are an integral part of the equipment to which
they refer and must be supplied to the user.

The product must be installed and serviced by qualified engineers,
in compliance with the prevailing standards.

ACV accepts no liability for any damage resulting from incorrect
installation or from the use of components or fittings not specified by
ACV.

Failure to observe instructions regarding tests and
test procedures can result in personal injury or
pollution risks.

Note:
ACV reserves the right to modify the technical specifications and
components of its products without prior notice.

INDEX

INTRODUCTION

INTRODUCTION

Intended users of these instructions
Symbols
Applicable standards
Warnings

FUNCTIONING

General
Functioning of domestic hot water
Functioning ofcentral heating

INSTALLATION

Mounting boiler
Circuit connections
Gas connection
Air + fluedas ducts
Frost protection
Setting Gas-Air ratio control
Electrotechnical connection
Put into operation
Put out of operation

USER GUIDE

Using the boiler
Control Settings

MAINTENANCE

DESCRIPTION

DIMENSIONS

ELECTRICAL WIRING

Electrical wiring prestige 47/64
Electrical wiring prestige 85

BOILER FEATURES

SERVICE RECORD

Installation record

Содержание Prestige 47

Страница 1: ...66400400 excellence in hot water Prestige 47 64 85 Installation Operating and Servicing Instructions...

Страница 2: ...h the prevailing standards ACV accepts no liability for any damage resulting from incorrect installation or from the use of components or fittings not specified by ACV Failure to observe instructions...

Страница 3: ...l heating situations For more information take contact with our local distributor MOUNTING BOILER The boiler should be installed in accordance with all the local and regional regulations 1 The boiler...

Страница 4: ...t by turning the white plastic screw on the gas valve clockwise higher CO2 counter clockwise lower CO2 In case the installation is supplied with a different type of gas the boiler has to be re adjuste...

Страница 5: ...n USING THE BOILER Your system should be serviced at least once a year by a qualified engineer If the boiler is subject to heavy use it may require servicing more than once a year consult your service...

Страница 6: ...b52 T5 T5max b61 airflowsensor closed b65 wait for fanstart Internal control Burner on for holding boiler warm Burner high function Testmode max RPM in CH mode Burner low function Testmode min RPM in...

Страница 7: ...sensor NTC2 check that the shunt pump is operating and if so vent the boiler if the fan is turning check the PWM connection if the problem persists after 2 resets change the fan if the problem persist...

Страница 8: ...e the burner hood Now the burner can be removed Inspect the fire chamber and the burner The burner can be cleaned with a nylon brush never use a steel brush on the inside so not on the side of the fla...

Отзывы: