IMPORTANT NOTES
This manual forms part of the items delivered with the appliance and
must be given to the user to keep in a safe place!
The system must be installed, commissioned, serviced and repaired by
an approved installer, in accordance with current standards in force.
The manufacturer declines all liability for any damage caused as a
result of incorrect installation or in the event of the use of appliances or
accessories that are not specified by the manufacturer.
The manufacturer reserves the right to change the
technical characteristics and features of its products
without prior notice.
The availability of certain models and their accessories
may vary from market to market.
IF YOU SMELL GAS:
Gas leaks may cause an explosion that may result in
serious injury.
- Do not smoke! Keep away from naked flames or equipment that
produces sparks.
- Do not use electrical appliances and do not operate switches
- Close the gas supply valve.
- Ventilate the room by opening doors and windows.
- Make sure that there is nobody in the danger zone.
- Notify the gas and electricity providers from outside the building.
- Turn off the building’s electricity supply from a safe place (outside the
building).
FROST PROTECTION
The boiler features a built-in frost protection mechanism: as soon as the
boiler temperature [NTC1 sensor] drops below 7°C, the central heating
pump is activated. As soon as the flow temperature falls below 3°C, the
burner starts up until the flow temperature rises above 10°C. The pump
continues to run for around 10 minutes.
If an outdoor temperature probe is connected, the circulator is activated
when the outside temperature drops below the preset threshold.
In order to enable the HeatMaster® TC boiler to protect the system
against freezing, all the valves of the radiators and the convectors
should be completely open.
WHO SHOULD READ THESE INSTRUCTIONS
These instructions should be read by:
- the design engineer/consultant
- the user
- the installer
- the service engineer
SYMBOLS
The following symbols are used in this manual:
Essential instruction for the correct operation of the
installation.
Essential instruction for the safety of persons and the
environment.
Electrocution hazard: use a qualified technician.
Burn hazard.
RECOMMENDATIONS
• Before installing and bringing the boiler into service, first
carefully read this manual.
• It is prohibited to modify the interior of the appliance in any way,
without the manufacturer's prior written agreement.
• The boiler must be installed by a qualified engineer, in
accordance with applicable local standards and local codes in
force.
• Failure to follow the instructions describing test operations
and procedures could result in personal injury or a risk of
environmental pollution.
• In order to ensure the appliance operates safely and correctly, it
is important to have it serviced by an approved contractor.
• If there is a problem please contact your contractor for advice.
• In spite of the strict quality standards that ACV applies to its
appliances during production, inspection and transport, faults
may occur. Please notify your approved contractor immediately
of any faults.
Remember to give the fault code displayed on the screen.
• Defective parts can only be replaced with original factory parts.
• The burners are preset in the factory.
• Specific regulation in Belgium:
The CO
2
, gas flow, air flow and air/gas supply parameters are
adjusted in the factory and cannot be changed in Belgium.
• Before carrying out any work on the boiler, it is important to
isolate the electrical supply to the unit.
• The user must not attempt to gain access to the components
inside the boiler or the control panel.
• This appliance is not intended for use by persons with reduced
physical, sensory or mental capacities , or lack of experience
and knowledge (including children) , unless they have been
supervised or instructed concerning use of the appliance by a
person responsible for their safety.
SAFETY PRECAUTIONS
MAXIMUM OPERATING CONDITIONS
Maximum operating pressure (tank full of water)
- Primary circuit:
3 bar
- Secondary circuit:
10 bar
Maximum operating temperature: 90°C
Water quality:
- Chlorides: < 150 mg/l
- 6 ≤ pH ≤ 8
If the water hardness is above 20°fH, we recommend
installing a water softener.
EN • 3
664Y5300 • A
E