Acuity Brands Lighting AFFINITY AFF OELR Скачать руководство пользователя страница 3

Page 3

INSTALLATION and WIRING 

1

2

Ensure all wires and 
connectors are routed to 
avoid interference with other 
components. Line up the 
Alignment pins (located at 
diagonally opposite corners 
of the front housing) with the 
mating receptacles (two on 
the rear housing). 

To properly close the unit, it is 
important to push the cover 
straight onto the rear housing. 
If the pins are not aligned with 
the receptacles, the housing 
will not close properly. Make 
sure there are no gaps 
between the front and rear 
housings.  If gap is present, 
open the unit and reinstall the 
front housing.

FINAL ASSEMBLY

SURFACE CONDUIT MOUNTING

NOTE: to avoid interference with components in the housing, use the most compact wire connectors appropriate to the wire gauge.

Alignment pin

Sheet metal 
clip

LIFE SAFETY SOLUTIONS

TEL:  800-705-SERV (7378

www.lithonia.com

[email protected]

Press and hold “Forward/Wide" button (Refer Page 5, Fig 1) for about 9 seconds to switch light beam aiming.

1

AFFINITY

®

1

PREPARING THE UNIT FOR CONDUIT : 

Remove the conduit plug from inside.  The unit 
is threaded to accept 1/2” NPT threads (14 
TPI), which are common in rigid conduit and 
EMT connector products. Rigid conduit or 
EMT fittings can be directly threaded into the 
housing without the need for a locknut, or for 
wet locations, use an approved wet location 
fitting.

2

BRANCH CIRCUIT WIRING :

The wiring compartment is sized for (3) incoming 12 AWG wires 
and (3) outgoing 12 AWG wires and common wire connectors. If 
your branch circuit is a larger AWG or you have a need for a 
through-wire application, install the branch circuit raceway such 
that you do not have to pass the circuit through the fixture.

Conduit plug

Open 

(Clockwise) *

Sized for ½” conduit

* A right angle screwdriver may be required to break 
the plug from the paint 

SWITCH AIMING (FCT optics)

Note:  Ships standard as WT option (wide throw mode)

912-00021-002 

Rev. CA, 2/2020

© 2020, Acuity Brand Lighting,Inc. 

All Rights Reserved.

Содержание AFFINITY AFF OELR

Страница 1: ...Do not exceed fixtures ambient temperature 40 F 122 F 40 C 50 C Use of unauthorized input voltage voids warranty and UL listing of this product and may present a risk of fire or explosion WARNING Do n...

Страница 2: ...he supply leads through the junction box and prepare the lead ends to make connections to the fixture leads On the rear housing remove the round center knockout 1 2 diameter and the desired pair of ke...

Страница 3: ...Press and hold Forward Wide button Refer Page 5 Fig 1 for about 9 seconds to switch light beam aiming 1 AFFINITY 1 PREPARING THE UNIT FOR CONDUIT Remove the conduit plug from inside The unit is threa...

Страница 4: ...crews from the plastic cover and charger board and take them out 1 2 Remove the mounting screws from bracket and remove the lamp assembly and carefully unplug connectors from lamp assembly Reconnect t...

Страница 5: ...BOARD REPLACEMENT Connector To remove IR board release snaps Federal Communications Commission FCC Requirements This device complies with FCC Title 47 Part 15 Subpart B this device does not cause harm...

Страница 6: ...DE CES SUBSTANCES POURRAIT ENDOMMAGER LE LUMINAIRE ET ENTRA NER DES BLESSURES CORPORELLES AVERTISSEMENT RISQUE DE BLESSURES CORPORELLES Ce produit peut avoir des bords tranchants Portez des gants pou...

Страница 7: ...travers le bo tier de raccordement et pr parez les extr mit s des fils pour effectuer les connexions aux fils du luminaire Sur le bo tier arri re enlevez le trou central rond 1 2 po de diam tre et la...

Страница 8: ...intenez le enfonc pendant environ 9 secondes pour modifier l orientation du faisceau lumineux 1 1 PR PARATION DE L APPAREIL POUR LE CONDUIT Retirer le bouchon du conduit de l int rieur L appareil est...

Страница 9: ...lastique et de la carte du chargeur principale et retirez les 1 2 Retirez les vis de fixation du support et retirez l ensemble du luminaire et d branchez soigneusement le connecteur de l ensemble de l...

Страница 10: ...AI TAT Connecteur Pour retirer la carte IR retirez les boutons pression Normes de la Commission f d rale des communications FCC Federal Communications Commission Cet appareil est conforme la FCC titre...

Страница 11: ...ONES PERSONALES este producto puede tener bordes afilados Use guantes para evitar cortes o abrasiones al extraer el producto de la caja manipularlo instalarlo o repararlo ADVERTENCIA No exceda la temp...

Страница 12: ...extremos de los cables para realizar las conexiones a los cables del dispositivo En la carcasa trasera retire el orificio central redondo 1 2 in de di metro y el par de orificios troquelados deseados...

Страница 13: ...ST consulte la p gina 5 Fig 1 durante aproximadamente 9 segundos para cambiar el enfoque del haz de luz 1 1 PREPARE LA UNIDAD PARA EL CONDUCTO Retire el tap n del conducto desde el interior La unidad...

Страница 14: ...del cargador y s quelos 1 2 Retire los tornillos de montaje del soporte y retire el montaje de la l mpara y desenchufe cuidadosamente los conectores del montaje de la l mpara Vuelva a conectar los con...

Страница 15: ...UEBA ESTADO DEL INTERRUPTOR Conector Para retirar el montaje de la l mpara libere los broches Requisitos de la Comisi n Federal de Comunicaciones FCC Este dispositivo cumple con el T tulo 47 de la FCC...

Отзывы: