READ AND FOLLOW ALL SAFETY INSTRUCTIONS!

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

· 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/

abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and 

all fixture labels.  

· 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general 

precautions.

· 

Installation and service of luminaires should be performed by a qualified licensed electrician. 

· 

Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and 

operation and any hazards involved.  Regular fixture maintenance programs are recommended. 

· 

It will occasionally be necessary to clean the outside of the refractor/lens.  Frequency of cleaning will depend on 

ambient dirt level and minimum light output which is acceptable to user.  Refractor/lens should be washed in a 

solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.  

Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing 

damaged gaskets as necessary. 

· 

DO NOT INSTALL DAMAGED PRODUCT!  This luminaire has been properly packed so that no parts should have 

been damaged during transit. Inspect to confirm.  Any part damaged or broken during or after assembly should 

be replaced.

· 

Recycle: For information on how to recycle LED electronic products, please visit 

www.epa.gov

· 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible 
contingency to meet in connection with installation, operation, or maintenance.  Should further information 
be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s 
purposes, this matter should be referred to Acuity Brands Lighting, Inc. 

 

Disconnect or turn off power before installation or 

servicing.

 

Verify that supply voltage is correct by comparing it with 

the luminaire label information.

 

Make all electrical and grounded connections in 

accordance with the National Electrical Code (NEC) and 

any applicable local code requirements.

 

All wiring connections should be capped with UL 

approved recognized wire connectors.

WARNING

RISK OF ELECTRIC SHOCK

 

Allow lamp/fixture to cool before handling. Do not 

touch enclosure or light source.

 

Do not exceed maximum wattage marked on 

luminaire label. 

 

Follow all manufacturer’s warnings, recommendations 

and restrictions for: driver type, burning position, 

mounting locations/methods, replacement and 

recycling.   

WARNING

RISK OF BURN

CAUTION

RISK OF FIRE

 

Keep combustible and other materials that can burn, 

away from lamp/lens.  

 

Do not operate in close proximity to persons, 

combustible materials or substances affected by heat 

or drying. 

CAUTION

RISK OF INJURY

 

Wear gloves and safety glasses at all times when 

removing luminaire from carton, installing, servicing or 

performing maintenance.

 

Avoid direct eye exposure to the light source while it is on.

Содержание AARP

Страница 1: ...aced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every p...

Страница 2: ...minaire that are not factory wired to the luminaire must be checked for compatibility with the luminaire prior to installation LED fixtures must be powered directly off a switched circuit Unless indiv...

Страница 3: ...s device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference rec...

Страница 4: ...r 8 Lithonia drilling pattern and has 3 holes The top and bottom hole are threaded b The longer bar has one top hole and a slot with a slid ing threaded hole to be used on poles with existing drill pa...

Страница 5: ...second bolt through the arm slot and into the available threaded hole of the mounting bar See Fig 4 5 The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the...

Страница 6: ...Tools Required 5 8 Socket wrench 3 16 Allen wrench 5 32 Allen wrench Minimum tenon pole diameter 2 schedule 40 pipe 2 3 8 OD 1 Slip luminaire Mast Arm Mount over 2 3 8 pole tenon See Figure 7a 2 Use...

Страница 7: ...e set screws enough to flip the luminaire over as shown below in figure 8a then loosen the six captive screws on door to access the wire connection area Remove the rubber grommet see figure 8b before...

Страница 8: ...ground connection and lock it Repeat this step for black hot and white neutral wires Select matching colored wires coming from SPD See Figure 9a 9b 9c 6 Use cable tie and bundle all newly attached wir...

Страница 9: ...ided 7 16 14 x 4 1 2 bolt through Mast Arm Mount and drilled 1 2 hole on tenon and place provided 7 16 nut onto bolt see figure 12 and tighten securely to 45 50 ft lbs 9 Evenly tighten the Six 6 3 8 1...

Страница 10: ...the splice access cover and pull supply wire leads from knuckle cavity See figures 13a and 13b 2 Slip luminaire knuckle fitter over 2 3 8 pole tenon and evenly tighten the six 6 3 8 16 UNC knuckle ten...

Страница 11: ...oximately 38 ft lbs See figure 14 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted from 0 to 45 from horizontal per ANSI C136 10 2010 7 Energize the luminair...

Страница 12: ...BA and secure to wall with secure base plate to wall with 4 1 4 diameter fasteners not included with luminaire using the 4 holes located on the outer corners of the base plate Check the base plate to...

Страница 13: ...ge components and void warranties 6 Make sure no wires are pinched and tuck excess wire up into the luminaire mounting area and reinstall the SPA Cover that was removed in step 3 Tighten the two cover...

Страница 14: ...is mounted securely to the pole the angle of the luminaire can be safely adjusted 3 If the luminaire angle will be adjusted DO NOT pull the luminaire supply wires taut leaving slack in the input wires...

Страница 15: ...Screwdriver AAWSC only Minimum Square Pole 3 5 Face Minimum Round Pole 3 2 Diameter CAUTION APPLY A CONTINUOUS BEAD OF WEATHER PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO ENSURE WEATHER TI...

Страница 16: ...om set screws to the same length 5 Now alternating between the top and bottom sets of set screws gently tighten until snug If the base plate was installed level approximately 1 threads should be visib...

Страница 17: ...ult setting is maximum output install luminaire as normal 1 Loosen six captive screws and remove RSX door to access the luminaire electronics Fig 23 Set aside for reinstallation 2 In all RSX family lu...

Страница 18: ...lithonia com Part Number IM 459 Rev A Revision Date 8 29 19 3 Make sure that wires and door tethers are not pinched and that the door gasket is still snugly in its groove on the door Re install the mo...

Отзывы: