background image

- 5 -

- 4 -

4 • OPERATION

6 • TROUBLESHOOTING

After the main unit and the wireless sensor are both powered on and wirelessly 

synchronized, no further input is required. If you have problems receiving the 

outdoor temperature, please refer to the troubleshooting section of this manual.

Minimum/Maximum Recorded Temperatures  

The main unit has a memory function for storing minimum and 

maximum recorded outdoor temperatures. The minimum and maximum 

temperature records will be reset every 24 hours. The 24 hour period is 

dictated by when the unit is powered up.

B

Trend Indicator Icons  

The main unit features arrow icons for indicating a falling, steady or 

rising temperature. This feature is shown for the outdoor and indoor 

temperatures.

A

ºC/ºF Selection

Press this button to switch between ºC or ºF temperature scale selections.

C

Problem

Bad Temperature

Reception

Relocate the main unit and/or the wireless

sensor. Both units must be within 100 feet

from each other. Make sure both units are

placed at least 3 feet from other electronic 

appliances and devices that may interfere

with the wireless communication (such as

TV’s, microwaves, computers etc).

Main Unit

Display Not Working

Make certain that the batteries are installed

correctly. The batteries may need replacing.

If none of the above solutions resolve the

problem, you may need to reset both units

by removing and re-installing the batteries

in both units.

Possible Solution

Product Registration

To receive product information, register

your product online. It’s quick and easy!

Log on to 

http://www.chaneyinstrument.com/product_reg.htm

FLASHING TEMPERATURE

Extended periods of cold temperatures ( below -4ºF / -20ºC 
) can cause alkaline batteries to function improperly. This 
will cause the outdoor wireless sensor to stop transmitting 
temperature readings. Use lithium batteries in these low 
temperature conditions to ensure continued operation for 
wireless sensors placed outdoors.

40

OUTDOOR TEMPERATURE

INDOOR TEMPERATURE

MAX

MIN

ºC/ºF

A

A

B

C

Measurement Ranges

Temperature

Main Unit: 32ºF to 122ºF   /   0ºC to 50ºC

Wireless Sensor: -40ºF to 158ºF   /   -40ºC to 70ºC

Specifications

Power Requirements

Main Unit: 2 x “AA” alkaline batteries

Wireless Sensor: 2 x “AA” alkaline or lithium batteries

Wireless Communication

Radio Frequency: 433 mhz

Transmission Intervals: every 16 seconds

5 • PRODUCT SPECIFICATIONS

This product features a low power wireless signal, so it does not interfere 

with other wireless devices in your location. Occasionally, there will be a 

temporary disconnection to the wireless sensor. In most cases, the 

temperature will show again if the main unit and wireless temperature 

sensor are able to re-connect automatically. If the disconnection lasts longer 

than a few hours, refer to this troubleshooting guide.

Отзывы: