5. FUNCTIONNING
Below described the main operating configuration. In case your product does not meet the following schemes, please look at
ACTUATECH catalogue or contact us.
5.1 Double acting (DA) actuator
Supplying air into port (2) actuator shaft rotates counter-clockwise (CCW) to open the valve. Conversely, supplying air into port (4)
actuator shaft rotates clockwise (CW) to close the valve.
5.2 Spring Return (SR) FAIL TO CLOSE
Supplying air into port (2) pistons move outward compressing the springs and actuator shaft rotates counter-clockwise (CCW) to open
the vale. Closing action is realized stopping air feeding. Springs energy push pistons back and consequently shaft rotates clockwise
(CW).
To avoid dust or solid particles incoming, close port (4) using a cap. In case of explosive environment use protection caps in complian-
ce with National safety/technical Standards or Regulations.
Counter-clockwise
Rotazione antioraria
dell'albero
rotation of the shaft
2
Counter-clockwise
Rotazione antioraria
dell'albero
rotation of the shaft
2
Rotazione oraria
dell'albero
Clockwise rotation
of the shaft
4
Rotazione oraria
dell'albero
Clockwise rotation
of the shaft