EN -
28
IT
EN
DE
FR
ES
RU
ACTUATECH S.p.A.
Via S. Lorenzo, 70, 25069 Villa Carcina (BS) Italy
Ph.
+39 030 8908142 •
Fax
+39 030 8908143 • [email protected] •
www.actuatech.com
Reference MAN81566 - 05/21
INSTRUCTION MANUAL
RP: RACK & PINION PART TURN PNEUMATIC ACTUATOR
RP10 - RP480
R.
Assemble caps, if necessary, replace O-Ring (23) placed in seat (24) and grease it. Connect caps to cylinder fastening screws
(25) crossway and in accordance to below torque instructions.
S.
Grease O-ring (15).
T.
Screw hexagon nut (17) for some threads on grub screw (18), insert washer (16) and O-Ring (15) along the grub screw (18).
U.
Screw grub screw (with pre-assembled components) in cylinder threaded hole using an Allen wrench. Pay attention, screw
starting form rounded end grub screw.
V.
See angle setting procedure on section 8.
W.
Grease O-Ring (11).
X.
Rest Namur plate (13) to cylinder surface (1) and fasten screws (14) in accordance to below torque instructions. Not all actuator
sizes are equipped with Namur plate (see section 3).
Double Acting (DA)
Spring Return Fail Close
Spring Return Fail Open
24
24
24
23
23
23
25
25
25
Warning!
In contact to cam
15
16
18
17
11
14
13
1