background image

IMPORTANT NOTE:

Please read this manual carefully before operating your new  remote control and keep it near the unit for future reference.

That’s better. That’s Actron.

RC-03

REMOTE CONTROLLER

Operation Manual

Suitable for

Mini Cassette 2 Cascade Series 2

 MRE-035CS

URC-100CS / CRE-100CS

MRE-053CS

URC-125CS / CRE-125CS

URC-125CS / CRE-140CS

Содержание RC-03

Страница 1: ... your new remote control and keep it near the unit for future reference That s better That s Actron RC 03 REMOTE CONTROLLER Operation Manual Suitable for Mini Cassette 2 Cascade Series 2 MRE 035CS URC 100CS CRE 100CS MRE 053CS URC 125CS CRE 125CS URC 125CS CRE 140CS ...

Страница 2: ...4 Remote Screen Indicators 5 05 Basic Functions 6 05 01 Mode Operation 6 05 02 Setting the Timer 7 06 How To Use Advanced Function 11 06 01 VANE Function not available for Mini Cassette 11 06 02 SWING Function 11 06 03 LED Display 11 06 04 QUIET Function not available for Mini Cassette 11 06 05 FREEZE PROTECTION FP Function 12 06 06 LOCK Function 12 06 07 BOOST Function 12 06 08 ECO GEAR Function ...

Страница 3: ...uipment Disposal Guideline Do not dispose off the waste electrical and electronic equipment with local council waste These must be disposed off through the council designated hazardous waste collection centre The equipment may contain hazardous substances improper or incorrect disposal may have a negative effect on human health and on the environment Remove batteries and separated from the rest of...

Страница 4: ...mer to turn unit On or Off 5 TEMP DOWN Decreases temperature in 0 5O C increments Min temperature is 16O C 6 FAN SPEED Selects fan speeds in the following order AUTO 20 40 60 80 100 7 BOOST Enables unit to reach preset temperature in shortest possible time 8 LED Toggles the LED display and buzzer of the air conditioner buzzer to On and Off 9 VANE Press to enter the louver setting mode NOTE This fe...

Страница 5: ...URE TIMER FAN SPEED Displays the set temperature by default or fan speed or timer setting when using TIMER ON OFF functions Temperature range 16o C 30o C 60o F 86o F Timer setting range 0 24 hrs Fan speed setting range Au 100 Humidity setting range 35 85 This display is blank when operating is FAN mode NOTE To display temperature in F press and hold the up and down arrows for 3 seconds while the r...

Страница 6: ... cool the room to the desired temperature 1 Press the button to select COOL mode 2 Set your desired temperature using the or buttons 3 Press the button to select the fan speed in a range of Auto 100 4 Press the button to start the unit HEAT Mode 1 Press the button to select HEAT mode 2 Set your desired temperature using the or buttons 3 Press the button to select the fan speed in a range of Auto 1...

Страница 7: ...in or near the blower and suction side of the unit The fan inside the unit may cause injury 05 02 Setting the Timer TIMER ON Auto On Operation The TIMER ON feature is useful when you want the unit to turn off automatically at a desired time Example To start the air conditioner in 6 hours Start Off 6 hours later Set 1 While the unit is OFF press the button 2 Press the or buttons to adjust the time ...

Страница 8: ...nt the remote controller to the indoor unit and wait for 1 second The indicator will show in remote controller and in the indoor unit panel to indicate that this function is activated OFF Indicator COMBINED TIMER Setting both ON and OFF timers simultaneously TIMER OFF TIMER ON On Stop Start operation This feature is useful when you want to stop the air conditioner after you go to bed and start it ...

Страница 9: ... is activated 4 Press the button until timer indicator is shown 5 Press the or buttons to adjust the time ON Indicator 6 Point the remote controller to the indoor unit and wait for 1 second Both the and indicators swill show this means that the function is activated TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and ...

Страница 10: ...ted 4 Press the button until timer indicator is shown 5 Press the or buttons to adjust the time OFF Indicator 6 Point the remote controller to the indoor unit and wait for 1 second Both the and indicators will show means that the function is activated NOTE When setting the TIMER the adjustable increment is 30 minutes up to 10 hours After 10 hours the increment will be 1 hour up to 24 hours NOTE In...

Страница 11: ...ess again to stop the swing 06 03 LED Display 1 Press the LED button to activate or de activate the display on the indoor unit 2 Press and hold the LED button for more than 5 seconds until it beeps release Then press and hold again for 5 seconds then release after beeps 3 After few seconds the room temperature shows 4 To revert to previous display repeat steps 2 and 3 To revert the change press LE...

Страница 12: ...te that the remote control buttons are locked 2 Press and hold the Boost and Vane buttons for 2 seconds to de activate lock function NOTES When pressing any button the lock icon will flash to indicate that the remote control buttons are locked All buttons are disabled whilst control has lock function ON 06 07 BOOST Function BOOST function is available on heating and cooling to accelerate the time ...

Страница 13: ...command to the unit ACTIVE CLEAN Function not available for Mini Cassette The Active Clean Function washes away accumulated dust mold and grease that may cause odors when it adheres to the heat exchanger The unit will automatically freeze the heat exchanger and then rapidly thaw the frost to wash and drain away the accumulated dirt When this function is activated the indoor unit display window sho...

Страница 14: ... minute interval Measuring room temperature from the remote control instead from indoor unit temperature sensor will enable the air conditioner to optimise the temperature around the user to ensure maximum comfort 1 Select follow Me in set menu 2 To activate press and hold the Boost button for at least seven seconds on will display on the screen for two seconds 3 To de activate press and the Boost...

Страница 15: ...THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 16: ...tron Engineering Pty Limited ABN 34 002767240 Registered Trade Marks of Actron Engineering Pty Limited ActronAir is constantly seeking ways to improve the design of its products therefore specifications are subject to change without notice Refrigerant Trading Authorisation No AU06394 ...

Отзывы: