35
A safety loop can simply be created by routing the pipe up and over an obstacle.
Remember to use pipe clips to securely fasten all hose connections.
4.
WEATHER PROTECTION
The heater must be installed within a dry weather proof enclosure.
If the heater is not used during winter months it must be drained to prevent frost
damage.
5.
TECHNICAL SPECIFICATIONS
5.1.
ELECTRICAL CONNECTION
The heater must be installed in accordance with the country / regional requirements
and regulations. In any event the work must be carried out by a qualified electrician,
who will provide a certificate of conformity upon completion of the work or the
warranty becomes void.
It is essential that the power supply to the heater is protected by a 30mA RCD (Re-
sidual Current Device). If in doubt consult a qualified Electrician.
5.2.
POWER REQUIREMENTS
230V 1 Phase-Power Output
Load
1 kW Lagune Spa Heater
5 Amp
3 kW Lagune Spa Heater
13 Amp
6 kW Lagune Spa Heater
27 Amp
5.3.
FLOW REQUIREMENTS
The flow rate of water into the heater must not exceed 17,000 litres per hour (3,740
UK gallons/hour) A higher flow rate will require the installation of a bypass to pre-
vent damage to the heater elements. The heater will not operate with a flow rate
below 1,000 litres / hour (220 UK gallons/hour).
5.4.
WATER QUALITY
The water quality must be within the following limits:
• PH: 6,8-8,0
• Total alkalinity: 80-140 mg/litre
• Chloride Content MAX: 150 mg/litre
• Free Chlorine: 2,0 mg/litre
• Total Bromine: max 4,5 mg/litre
• TDS (Total Dissolved Solids) / Ca)lcium hardness: 200-1.000 mg/litre
TIP!
NOTE!
FI
DE
PL
DK
SE
NO
GB