2. POSITIONING
Your heater should be horizontally or vertically sited allowing sufficient space for
pipe connections and wiring, it should be screw fixed securely to a firm base or wall.
The heater should be installed at a low point in the filtration system. It should be
positioned downstream (after) of the filter and upstream (before) of any dosing or
other water treatment plant (see fig.2).
3.
PIPE WORK
It is essential that the pipe work connecting to and from the heater has a minimum
bore (internal diameter) of 1¼” (32mm).
To assist correct air purging and to ensure the heater remains completely full of water
during operation, the return pipe which carries the water back to the pool must incor-
porate a safety loop or ‘kick-up’ in the pipe as close as possible to the heater (see fig 3).