background image

Page 11

© 2005 Active Research Limited

Specifications

Parameter

Conditions

Min.

Max.

Unit

Supply

Supply voltage

8

35

V

Supply current (see note 1)

Supply voltage = 12v

26

30

mA

Supply voltage = 24v

16

18

mA

NMEA

Input voltage b/-

Logical ‘1’/stop bit

-15.0

0.5

V

Logical ‘0’/start bit

4.0

15.0

V

Input current

Maximum is under +35v overload 

condition

2.0

30

mA

Differential input voltage

Required level for NMEA to be 

detected

1.8

2.0

V

Output voltage b/- and ground 

(see note 2)

Logical ‘1’/stop bit

0.0

0.5

V

4.8

5.2

V

Output current (see note 2)

At maximum load, drive voltage 

reduces to 2v

-

32

mA

Output short circuit current. 

50

55

mA

Baud rate - fixed (see note 3)

4.8

kbit/sec

Data propagation delay

1.0

100

ms

RS-232

Input voltage range

-15

+15

V

Input voltage threshold

LOW

0.8

1.2

V

HIGH

1.7

2.8

V

Output voltage swing 

Loaded with 3

κ

Ω 

to Ground

±5

±9

V

Output resistance

(RS232 Vout

 

 

= ±2v)

300

Ohms

Output short circuit current 

(Infinite duration)

±18 

mA

Baud rate (see note 4)

38.4

kbit/sec

Data propagation delay

1.0

100

ms

General

Ambient temperature

-20

+70

°C

Table 2 – NDC-3 specifications

All specifications are taken with reference to an ambient temperature (T

A

) of +2

5

°C.

Note:

1.  Current consumption measured under no-load conditions

2.  NMEA output is RS-485 compatible.

3.  NMEA 0183 inputs and outputs on the NDC-3 are fixed to 4800 baud

4.  RS232 baud rate is fixed at 38400 baud on the NDC-3

Содержание NDC-3

Страница 1: ...er NDC 3 B User Manual Issue 1 31 Multiple talker interface for use with the NMEA 0183 standard Serial data networking of marine electronic devices instruments Personal computer RS232 interface to NME...

Страница 2: ......

Страница 3: ...mpatible RS 232 bi directional port 5 Technical features 5 Software updates 5 Connecting devices together 6 The basics 6 The NMEA signals 6 The different NMEA standards 6 Connections 7 Connecting to N...

Страница 4: ...n the NMEA sentence is validated Therefore the electronic device s supplying the NDC 3 with NMEA data retain s the sole responsibility for the NMEA data s validity Foreword Actisense recognises that i...

Страница 5: ...m drive capability The full differential output ensures better quality communications and lower noise emissions on unshielded twisted pair cabling Full speci cation RS232 interface ensures that any ma...

Страница 6: ...ine Tx or Out and used the ground as the other line similar to the way a computer serial port works This connection method is referred to as single ended instead of the differential method used by NME...

Страница 7: ...to a Personal Computer PC or other marine device capable of interfacing to a standard RS 232 port 4 Battery supply input Note 1 To complete the NMEA 0183 standard all device interconnection NMEA cable...

Страница 8: ...connection ID s Simply connect A to A and B to B refer to gure 2 NMEA Talker device 3 This device does not conform completely to the NMEA 0183 standard However by connecting to A and its G Ground to t...

Страница 9: ...ine and one for the RX line Use the spare wire in each pair as ground and connect the cable shield to ground only at the computer end 3 The TX of the NDC 3 should be connected to the RX of the compute...

Страница 10: ...ion Also indicates that no data is currently being received by the NDC 3 hardware Green Flashing 1 10 per second Normal and data Rx mode No error No response required A normal operation mode that indi...

Страница 11: ...e reduces to 2v 32 mA Output short circuit current 50 55 mA Baud rate xed see note 3 4 8 kbit sec Data propagation delay 1 0 100 ms RS 232 Input voltage range 15 15 V Input voltage threshold LOW 0 8 1...

Страница 12: ...202 746682 International 44 1202 746682 Fax 01202 746683 International 44 1202 746683 Actisense on the Web For advice support and product details E mail support actisense com Website www actisense com...

Отзывы: