background image

Page 8

© 2005 Active Research Limited

NMEA 0183 Inputs

The  NMEA  0183  differential  opto-isolated  inputs  are 

designed  to  handle  a  variety  of  NMEA  0183  device 

output  specifications. Please determine (from device

manufacturer’s  information)  if  the  device(s)  required  to 

be connected to the 

Actisense™

 NDC-3 conforms in full 

to the NMEA 0183 network communication standard. If it 

does not, the flexible

Actisense™

 NDC-3 inputs should 

still be capable of interfacing with the device, though this 

is not guaranteed.  

The diagram above shows a typical installation with both 

fully  compliant  NMEA  devices  with  differential  inputs/

outputs,  and  non-differential  output  devices  that  output 

NMEA using the ground line as the “

NMEA -

” line.

NMEA  Talker  devices  1,  2  and  4: 

These  devices 

conform  in  full  to  the  NMEA  0183  standard.  Devices 

1  and  4  share  the  same  connection  ID’s  as  the 

Actisense™ 

NDC, so connection is a simple matter of 

matching the ID’s (refer to figure 2). Device 2 uses the

RS485 convention connection ID’s. Simply connect ‘

A

‘ 

to ‘

+/A

‘ and ‘

B

’ to ‘

 -/B

’ (refer to figure 2).

NMEA Talker device 3: 

This device does not conform 

completely to the NMEA 0183 standard. However, by 

connecting ‘

+

‘ to ‘

+/A

‘ and its ‘

G/Ground

’ to the NDC 

-/B”

 the NDC should be able to receive the NMEA data 

correctly.

NMEA 0183 Output

The NMEA 0183 buffered output is capable of driving up 

to  15  NMEA  0183  fully  compliant  listening  devices,  or  a 

mixture of NMEA 0183 devices and a Personal Computer 

(PC) communication port.

NMEA  Listener  device’s  B  and  C: 

These  devices 

conform in full to the NMEA 0183 standard and their 

connection ID’s match that of the NDC.

Personal Computer: 

Whilst the RS-232 port is designed 

for connection to a PC, the NMEA 0183 output is also 

capable of being read by most PC’s. Simply connect ‘

+

’ 

to ‘

Rx

’ and ’

G

’ to 

‘Gnd

’ on a standard D-type (probably 

male) connector.

NMEA  Listener  device  A: 

This  device  does  not 

conform in full to the NMEA 0183 standard. However, 

by  connecting  ‘

-

‘  to  ‘

-/B

‘  and  ‘

G/Ground

’  to  ‘

Gnd

’ 

the device should be able to receive the NMEA data 

correctly, though this is not guaranteed.

Note: 

1.   Wire colours are for guidance only. 

Connecting to NMEA devices

Figure 2 – NMEA 0183 connections

NMEA DA

TA COMBINER

99999

NDC

-3-B

��������

��������

��

����

����������

����

����������

����

����������

����

��������

����

��������

����

��������

����

��������

Содержание NDC-3

Страница 1: ...er NDC 3 B User Manual Issue 1 31 Multiple talker interface for use with the NMEA 0183 standard Serial data networking of marine electronic devices instruments Personal computer RS232 interface to NME...

Страница 2: ......

Страница 3: ...mpatible RS 232 bi directional port 5 Technical features 5 Software updates 5 Connecting devices together 6 The basics 6 The NMEA signals 6 The different NMEA standards 6 Connections 7 Connecting to N...

Страница 4: ...n the NMEA sentence is validated Therefore the electronic device s supplying the NDC 3 with NMEA data retain s the sole responsibility for the NMEA data s validity Foreword Actisense recognises that i...

Страница 5: ...m drive capability The full differential output ensures better quality communications and lower noise emissions on unshielded twisted pair cabling Full speci cation RS232 interface ensures that any ma...

Страница 6: ...ine Tx or Out and used the ground as the other line similar to the way a computer serial port works This connection method is referred to as single ended instead of the differential method used by NME...

Страница 7: ...to a Personal Computer PC or other marine device capable of interfacing to a standard RS 232 port 4 Battery supply input Note 1 To complete the NMEA 0183 standard all device interconnection NMEA cable...

Страница 8: ...connection ID s Simply connect A to A and B to B refer to gure 2 NMEA Talker device 3 This device does not conform completely to the NMEA 0183 standard However by connecting to A and its G Ground to t...

Страница 9: ...ine and one for the RX line Use the spare wire in each pair as ground and connect the cable shield to ground only at the computer end 3 The TX of the NDC 3 should be connected to the RX of the compute...

Страница 10: ...ion Also indicates that no data is currently being received by the NDC 3 hardware Green Flashing 1 10 per second Normal and data Rx mode No error No response required A normal operation mode that indi...

Страница 11: ...e reduces to 2v 32 mA Output short circuit current 50 55 mA Baud rate xed see note 3 4 8 kbit sec Data propagation delay 1 0 100 ms RS 232 Input voltage range 15 15 V Input voltage threshold LOW 0 8 1...

Страница 12: ...202 746682 International 44 1202 746682 Fax 01202 746683 International 44 1202 746683 Actisense on the Web For advice support and product details E mail support actisense com Website www actisense com...