Revised
September 27, 2016
Page | 8
Batteries and Charging (Continued)
To get maximum daily use, the battery must be fully charged. This is accomplished by
having the Trackchair plugged in and charging until the “READY LIGHT” comes on.
INDEPENDENT CHARGING BANK INDICATIONS
When your battery charging system is activated, each bank provides charging information utilizing five red
Light Emitting Diode (LED) indicators and one green Light Emitting Diode (LED) indicator.
The five red LEDs enable you to track the progress of the charge cycle on each battery as the voltage rises. (see
the following chart)
The charger can be left on for an extended period of time without harming the battery.
Your system provides an equalization stage every 30 days while plugged in. If the charger is normally
ddisconnected from A/C after completing charge, equalization can be accomplished by plugging back into A/C
whenever this stage is desired. Battery manufacturers recommend that equalization is done once a month in
order to further reduce sulfation on the lead plates of a battery, which helps promote longer battery life. Note:
During this process the LEDs will go through their normal routine (Red counting up for % of charge) and the
Green Led will blink until the unit returns to the maintenance mode and a steady Green LED. (Not applicable to a
Gel Profile)
2 to 12.78 volts = 10%
12.79 to 13.25 volts = 10%, 30%
13.26 to 13.49 volts = 10%, 30%, 50%
13.50 to 14.04 volts = 10%, 30%, 50%, 70%
14.05 to 14.52 volts = 10%, 30%, 50%, 70%, 90% Green Flashing
{Finishing Stage} 14.52 to 15.49 volts
Dual Pro