The   first   set   of
Scheduled   arm   and
disarm time setting

To set the time for scheduled arm and disarm,

Example: set up the first group scheduled time to arm  at 22 

 00 pm and

disarm at 07  

  00 am, this is valid for Monday, Tuesday, Wednesday,

Thursday and Friday of each week.

Method one: 

After calling and connected to the panel from remote, press

572200070012345#

Method two: 

Send SMS message 1234572200070012345# 

Remark:set the arm time and disarm time to be 24:00,would be closed the

scheduled arm/disarm function . 

Syntax:

 57 

 + 

 AAAA

Scheduled   time   of
arm  

+  

  BBBB

Scheduled   disarmed
time 

 + 

 Number of

week 

 + 

 # 

The   second   set   of
Scheduled   arm   and
disarm time setting

To set the time for scheduled arm and disarm,

Example: set up the second group scheduled time to arm  at 12 

 00 pm

and disarm at 13 

 00 am, this is valid for Monday, Tuesday, Wednesday,

Thursday ,Friday,Saturday and Sunday of each week.

Method one: 

After calling and connected to the panel from remote, press

58120013001234567#

Method two: 

Send SMS message 123458120013001234567#

Remark:set the arm time and disarm time to be 24:00,would be closed the

scheduled arm/disarm function .

Syntax:

 58 

 + 

 AAAA

Scheduled   time   of
arm  

+  

  BBBB

Scheduled   disarmed
time 

 + 

 Number of

week 

 + 

 # 

Set   the   type   of
defense zone

To set 6 wireless zones type, 01~06 represents 1-6zone number,  1-5
represents one of the 5 zone type:  

1.

NORMAL

2.

STAY ARM

3.

INTELLIGENT

4.

EMERGENCY

5.

CLOSED

The last 0/1 represents 0 siren of panel produce no sound upon alarming
while 1 is sounded.
Example: Set zone number 2 as STAY zone type, and siren not sound
upon alarming

Method one: 

After calling and connected to the panel from remote, press

600220#

Method two: 

Send SMS message 1234600220#

Syntax:

60

 + 

01-06 zone

number  

  +  

  1-5

Type 

 + 

 0/1 

 + 

Set mode  of  wired

alarm zone

Set wired alarm zone to NO or NC. The zone number of   07-10 are
wired defense zones, system default is 07-10 are wired zones with NO

Содержание AC3828

Страница 1: ...GSM SECURITY ALARM SYSTEM User Manual ...

Страница 2: ...lular phone or SMS Messages to configure and control the Panel remotely Six groups of phone numbers for voice calling and three groups for SMS Messages 10 seconds ISD automatic leaving message record Telephone phone long distance telephone control for arming disarming monitoring remote announcement One group of normally open signal output which can be externally linked to electrical appliances wit...

Страница 3: ... best transmission to all the wireless sensors and accessories Keep the panel well away from large metal objects or household appliances with high frequency interference and avoid barriers such as concrete walls with metal frame inside and fire doors function Indications Description Built in speaker short beep once KeyTip beep beep two short tones Exit configuration or learnt succeed beep beep bee...

Страница 4: ...end Press SET Key to exit setup status 3 3 Enable or disable the GSM Module System default the GSM module is on if the user not installed the SIM card the host will restart until find SIM card and GSM signal Remark If set the GSM module to off the alarm system only used as the live alarm system only cleared the police can not dialed the phone alarm number Moreover the host without the SIM card wou...

Страница 5: ...re Press SET 1s again the second defence zone indicator light on and voice prompt learning second zone to enter the configuration mode And so on for each of the rest defence zones Last press SET again alarm panel would be beep twice and all indicator light off to exit the configuration mode Alarm panel can configure up to 50 sensors of different addressing 3 7 Delete detector Delete the sensor of ...

Страница 6: ...h group alarm number correspondingly Example If the user wants to set 13812345678 for the first set of voice alarm phone number Method one Remote calling into the alarm panel put in password initial password 1234 when being asked then press the key hear the voice prompt means the host into setting state In remote setting press a digital then the host will broadcast one digital speech if press a di...

Страница 7: ...ber Used to delete the first group to SMS of the third group police number Example If you want to delete the first set of SMS message phone number Method one After calling and connected to the panel from remote press 37 Method two Send SMS message 123437 to the panel Syntax 3 7 9 Password modification Used to modify the user password the default user password is 1234 Example If you want to set up ...

Страница 8: ...he relay absorption would change the circuit condition between NO and COM The time of relay actuation is the same with siren sound time When disable the alarm linkage function the relay of the panel can remote control the home appliance After calling and connected to the panel from remote input the password press 9 the relay on 0 OFF Or send SMS 12343 ON 12344 Means OFF Can control the power which...

Страница 9: ...iday Saturday and Sunday of each week Method one After calling and connected to the panel from remote press 58120013001234567 Method two Send SMS message 123458120013001234567 Remark set the arm time and disarm time to be 24 00 would be closed the scheduled arm disarm function Syntax 58 AAAA Scheduled time of arm BBBB Scheduled disarmed time Number of week Set the type of defense zone To set 6 wir...

Страница 10: ...lue is from 00 to 99 as largest system default is the largest Example users need to set volume to 50 Method one After calling and connected to the panel from remote press 6250 Method two Send SMS message 12346250 Syntax 62 00 99 Auto dial up function when power off When power off auto dial function on or off 1 for on 0 for off the panel would not dial the pre set phone number Default is 0 Example ...

Страница 11: ...ress and hold the SETand power on Note Other than the SMS commands for assigning specific phone number for certain zone alarm panel will respond to all other SMS commands by replying confirmation of setting by SMS 4 2 Commands of System Enquiries The following instructions are only for SMS command to control panel remotely Remote SMS disarm Send SMS message 12340 into alarm panel Note 1234 is the ...

Страница 12: ...st to 3rd SMS alarm number 1 6 for 1st to 6th phone alarm number 7 9 for 1st to 3rd SMS alarm number Example Send 123421 to the alarm panel the alarm panel replies 1 13712345678 means the first voice alarm phone number is 13712345678 Remark phone alarm number can be the same as SMS alarm number 21 Query the system time and scheduled arm disarm time Query the system time Example Send 123422 to the ...

Страница 13: ...e alarm 2 The second zone message content 2 zone alarm 3 ditto 10 ditto 80 Customize the SMS message for certain zone Used to customize the SMS message for zone 1 9 this content is sent into the first to the third SMS message numbers users reset after this zone alarming content confined within 12 Letters Example Send message 123481 Front Door Alarm to the alarm panel will set alarm panel to send S...

Страница 14: ...numbers on list until one connected Panel will not ask for password when dialing out upon alarming Remark monitoring time is 20 seconds If continue to monitor user needs to press 3 key again Press 3 5 To support talkback function the host needs to connect to another passive loudspeaker which are 8 ohm and its power above 0 5 W 5 2 Remote Dialing In Operation Remote control operations can be done v...

Страница 15: ...ctors and emergency button etc 5 CLOSED Defense zone no matter arming or disarming status detectors will not alert even being triggered 6 2 Default Operation password 1234 Siren volume 99 Alarm linkage Enable 1 10zone type Normal GSM moudle Enable Siren sound 1minute Audible confirmation for remote operation Enable Delay ARM 0s Delay alarming 0s 7 10wired zone alarm type NO 1 10zone alarm Siren so...

Отзывы: