background image

12

actigraphcorp.com

10/19/2018  |  Revision: 0

Information for Subjects 

(Continued)

Setting up the CP Data Hub at home 

(If you are not using a CP Data Hub, skip ahead to 

Uploading Data to CentrePoint

)

The CP Data Hub should be placed at home in a location where the subject spends most of his or her time.

Connect the adapter end of the power cable into the back of the CP Data Hub and plug the other end into 
a wall outlet.

The blue LED on the back of the CP Data Hub will begin to flash during startup. Once the CP Data Hub 
connects to the cellular network, the blue LED will stay on solid.

Once the CP Data Hub is connected, use the USB cable to connect the charging dock to the CP Data Hub.

Insert the Insight Watch into the dock for charging or docked data uploads, as determined by the study 
parameters.

4

3

1

2

3

Power

Status Light

USB Port

Note: The Insight Watch automatically transmits raw data via Bluetooth® to the CP Data Hub each day. It 
is not necessary for the subject to dock the Insight Watch to upload data from home.

Содержание CentrePoint Insight Watch

Страница 1: ...User Guide CentrePoint Insight Watch Activity Monitor CentrePoint Insight Watch Revision 0 Released 10 19 2018 ...

Страница 2: ...le rate Battery life Data storage Specifications 1 97 x 1 35 x 0 41 in 14 grams 32 Hertz default 256 Hertz 30 days 30 days 512 MB Dynamic range Communication Water resistance Wear location Warranty 8G USB Bluetooth LE 5 1 meter 30 minutes Wrist 1 year At 32 Hz default sample rate User Guide CentrePointInsightWatch Activity Monitor CentrePoint Insight Watch Revision 0 Released 10 19 2018 Contents O...

Страница 3: ...graphcorp com 10 19 2018 Revision 0 What You ll Need PC ActiSync Software CentrePoint Account CentrePoint Insight Watch USB Cable CentrePoint Data Hub Power Cable optional Wall Charger optional Charging Dock ...

Страница 4: ...re Storage https acticlouduploadsprod blob core windows net 1 Main Web Portal https studyadmin actigraphcorp com 2 CentrePoint account setup Using the invitation link provided by ActiGraph or your study sponsor create a CentrePoint username and password Install ActiSync software Download the ActiSync software from https actigraphcorp com actisync Double click the file to open and follow prompts to...

Страница 5: ...able Connect the InsightWatch to the charging dock by pulling the plastic tab away from the dock and inserting the device with the screen facing up and the button on the opposite side of the cable port The Insight Watch is fully charged once a solid battery icon appears on the screen 1 2 3 4 Note An Internet connection is not required to charge the activity monitors Battery Life Specifications The...

Страница 6: ... checking for a small icon in the taskbar Connect the charging dock to the computer using the provided USB cable and insert the InsightWatch into the charging dock Once connected the ActiSync icon will turn yellow and a dialog box will open Select Assign the subject now Enter your CentrePoint login information to open the CentrePoint web page in your browser 1 4 3 2 1 ...

Страница 7: ...com 10 19 2018 Revision 0 Assigning the Insight Watch to a Subject Continued Complete the Device Assignment form and select Assign Device to a New Subject Wait for progress bar to indicate that assignment is complete 5 ...

Страница 8: ...ht Watch is now collecting data and can be given to the subject Active Mode The Insight Watch is collecting data Halt Stop icon will be displayed if the Insight Watch is not collecting data 6 Note To assign an activity monitor to an existing subject such as in the case of a lost or broken device complete steps 1 4 above and scroll to the bottom of the page Select the corresponding subject identifi...

Страница 9: ...power cable into the back of the CP Data Hub and plug the other end into a wall outlet Connect the charging dock to the USB port on the CP Data Hub using the USB cable Insert the Insight Watch into the charging dock Once connected a progress wheel will appear on the screen indicating that an upload has begun When the upload is complete a checkmark will appear on the screen 2 1 2 3 Upload in Progre...

Страница 10: ...m the left menu Select the desired subject from the list You will be directed to the Subject Details page Select the SubjectTimeline tab and verify that an upload has occurred via Data Hub USB The Insight Watch and the CP Data Hub are now paired Remove the Insight Watch from the charging dock Give the Insight Watch charging dock CP Data Hub USB cable and power cable to the subject 4 5 6 ...

Страница 11: ... the Insight Watch The Insight Watch can be worn for 24 hours a day dependent on the study parameters There is no need to remove the Insight Watch during regular bathing or swimming activities Charging the Insight Watch at home The Insight Watch has a battery life of approximately 30 days when using the default sample rate of 32 Hz For data collection periods lasting longer than 30 days subjects s...

Страница 12: ... outlet The blue LED on the back of the CP Data Hub will begin to flash during startup Once the CP Data Hub connects to the cellular network the blue LED will stay on solid Once the CP Data Hub is connected use the USB cable to connect the charging dock to the CP Data Hub Insert the Insight Watch into the dock for charging or docked data uploads as determined by the study parameters 4 3 1 2 3 Powe...

Страница 13: ...g dock connected to the PC Data will automatically upload to the CentrePoint system Once the upload is complete a browser window will open to display the Subject Upload Compliance page Mark the corresponding milestone and review wear compliance Remove the Insight Watch from the charging dock and return it to the subject for continued monitoring 1 2 3 ...

Страница 14: ... subject Follow steps 1 2 above to perform a final data upload From the Subject Details page select Stop Collecting Data to remove the subject assignment from the Insight Watch A Data Collection Complete tag will appear in the general tab under the Subject Details page Remove the Insight Watch from the charging dock and clean with an alcohol based solution 2 3 4 1 ...

Страница 15: ...gning a replacement Only one Insight Watch can be assigned to a subject at any given time To disassociate an Insight Watch select the Subjects tab from the left hand menu and select the desired subject from the list From the Subject Details page select either Lost monitor or Broken Damaged monitor Lost or Broken Activity Monitors 1 2 ...

Страница 16: ...Watch follow the instructions on page 8 for assigning a monitor to an existing subject 3 4 Note If you are using a CP Data Hub and disassociate an Insight Watch from a subject the CP Data Hub will automatically disassociate as well If a replacement Insight Watch is assigned it must also be paired with the CP Data Hub Lost or Broken Activity Monitors Continued ...

Страница 17: ... need to be charged It is recommended that the Insight Watch be fully charged once every 3 4 weeks How long does it take to charge the Insight Watch Approximately 2 3 hours How should the Insight Watch be cleaned The Insight Watch should be cleaned with an alcohol based solution wipes or swabs Q Q Q Q Q Frequently Asked Questions Note If an ActiGraph device is broken malfunctioning or does not app...

Страница 18: ...rticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outl...

Страница 19: ...dical device can be safely exposed Recycle Electronic Equipment Indicates the medical device should not be disposed of in the trash Contact ActiGraph Customer Service regarding the disposal of these products Lithium Ion EU Indicates the lithium ion battery within the device should not be disposed of in the trash Contact ActiGraph Customer Service regarding the disposal of these batteries 40C 20C M...

Страница 20: ... law restricts this device to sale by or on the order of a physician For Canada use The medical device registration for this product with Health Canada is scheduled for 2018 Until this is complete the device is to be used by Qualified Investigators Only as an Investigational Device following the ITA process ...