actiLib Library 4U
– User and Service Guide
Page 48 of 103
7.8.4 Element Reporting
The SCSI specification does not allow gaps in the SCSI element addressing. There is a special
handling needed for drive slots which are empty to fulfill the specification. Also drives which are
temporary removed needs to be handled correct to not confuse the attached host and host
application.
7.8.4.1
General Reporting
Generally only drives are reported which are currently ph
ysically available or “temporary”
removed.
Empty slots which are located at an edge should not be reported, with an exception in case of a
“removed” condition.
4U Unit with 3 HH drives
SCSI Element
Slot
4
3
3
2
2
1
1
7.8.4.2
Gaps
A drive slot which does not contain a drive and has a position between used slots will not be
reported.
4U Unit with 3 HH drives
SCSI Element
Slot
3
4
3
2
2
1
1
In case of installing a drive in a gap the SCSI elemts will be renumbered in contiguous order
without a gap.
Содержание actiLib Autoloader 4U
Страница 1: ...actiLib Library 2U User and Service Guide Page 1 of 103 actiLib Autoloader 4U User and Service Guide ...
Страница 38: ...actiLib Library 4U User and Service Guide Page 38 of 103 Figure 22 Interaction Mode Information ...
Страница 39: ...actiLib Library 4U User and Service Guide Page 39 of 103 Figure 23 Interaction Mode Information continuation ...
Страница 40: ...actiLib Library 4U User and Service Guide Page 40 of 103 Figure 24 Interaction Mode Commands ...
Страница 41: ...actiLib Library 4U User and Service Guide Page 41 of 103 Figure 25 Interaction Mode Configuration ...
Страница 42: ...actiLib Library 4U User and Service Guide Page 42 of 103 Figure 26 Interaction Mode Configuration continuation ...
Страница 43: ...actiLib Library 4U User and Service Guide Page 43 of 103 Figure 27 Interaction Mode Service ...
Страница 60: ...actiLib Library 4U User and Service Guide Page 60 of 103 Figure 40 Configuration license key ...