background image

www.acti.com

 
 

Hardware Manual 

               

Federal Communications Commission Statement 

This equipment has been tested and found to comply with the limits for a 

class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses, and can radiate radio frequency 

energy and, if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to radio or 

television reception, which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

Warning:

 Changes or modifications to the equipment that are not expressly approved by the 

responsible party for compliance could void the user’s authority to operate the equipment. 

 

European Community Compliance Statement 

This  product  has  been  tested  and  found  to comply  with the  limits for  Class  B 

Information Technology Equipment according to European Standard EN 55022 

and EN 55024. In a domestic environment, this product may cause radio interference in which 

cause the user may be required to take adequate measures. 

 

 

Содержание Q950

Страница 1: ...Intercom Camera Hardware Manual Q950 Q951 2018 03 08...

Страница 2: ...ount the Camera 16 Step 4 Connect to the Network 17 Step 5 Access the Camera Live View 17 Cable Connections 18 Connecting a Power Adapter Optional 18 Connecting DI DO Devices Optional 19 Using Door Lo...

Страница 3: ...www acti com Hardware Manual 3 Accessing the Camera 27 Configure the IP Addresses 27 Access the Camera 31...

Страница 4: ...g or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Trademarks ACTi and ACTi logo are registered trademarks of ACTi Corporation...

Страница 5: ...urning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Страница 6: ...y immediately and refer servicing to qualified service personnel under the following conditions 1 When the power supply cord or plug is damaged 2 If liquid has been spilled or objects have fallen into...

Страница 7: ...Introduction The List of Models This hardware manual contains the following models Q950 6MP Door Station Outdoor Intercom with D N IR Extreme WDR SLLS Fixed lens Q951 6MP Outdoor Door Station with D N...

Страница 8: ...e camera package comes with the following items Camera RFID Card Drill Template Hex Screw Driver Screws and Plugs Plug Insert 5 Pin Terminal Block 6 Pin Terminal Block 2 Pin Terminal Block x2 Quick In...

Страница 9: ...icrophone Receives audio input 8 Power LED Lights red when the camera is powered up 9 Reset Button Restores the factory default settings of the camera To reset the camera while the power is on press a...

Страница 10: ...ects to digital output devices such as a door relay alarm trigger etc See Connecting DI DO Devices Optional on page 19 for information 15 Network Connector Connects to a network using an Ethernet cabl...

Страница 11: ...use the mounting plate that comes with the camera to mount it on the wall Gangbox The mounting plate that comes the camera is compatible to be directly mounted on a two gang box one gang or four inch...

Страница 12: ...ace NOTE The following pictures are for reference only Step 1 Prepare for Installation 1 Attach the bundled drill template sticker on the target installation surface 2 Drill the screw holes and cable...

Страница 13: ...Cable 1 Open the back cover 2 If a memory card will be used install the memory card at this point Otherwise skip this step See How to Install Remove the Memory Card on page 26 for more details 3 Remov...

Страница 14: ...rubber plug Use the supplied terminal blocks to connect other devices See Cable Connections on page 18 for detailed instructions Although the steps below show only the network cabling similar procedur...

Страница 15: ...www acti com Hardware Manual 15 8 Attach the screws to secure the back cover...

Страница 16: ...www acti com Hardware Manual 16 Step 3 Mount the Camera 1 Mount the camera into the mounting plate 2 Using the bundled hex screw driver secure the two 2 screws on the bottom side of the plate...

Страница 17: ...ork AC Power Source PoE Injector PoE Switch Power Cable Ethernet Cable Ethernet Cable Data Power Ethernet Cable Data Camera In case of using a non PoE switch power up the camera using a power adapter...

Страница 18: ...mited power supply you can purchase a power adapter and directly connect the camera to a power outlet The power adapter must be connected to the supplied terminal block before use Map the pins of the...

Страница 19: ...connect the terminal block to the camera Below is a diagram on how the Digital Output Input of the camera work Using Door Locks with Internal Switch Below is an example on how to integrate a door loc...

Страница 20: ...und b Using another wire map COM1 and GND pins of the terminal block refer to the curved red wire on the picture below 4 Power up the door lock to a DC 12V power separately map the red wire on the doo...

Страница 21: ...rmware Manual for more detailed information a Configure the Digital Output Port b Configure the Event The example configuration below triggers the door lock to become active to open the lock and light...

Страница 22: ...ge To trigger low Logic level 0 0V 0 4V Normal high Logic level 1 3 1V 30V Current 10mA 100mA DO Connection design Form C Solid State Relay Isolation test voltage 3750 VRMS Typical RON 20 DC or peak A...

Страница 23: ...eaker at one time By default the camera is configured to use the built in speaker Using the Built In Speaker To use the built in speaker do the following 1 Make sure the Audio Switch is set to Built i...

Страница 24: ...orresponding pins on the terminal block Press and hold the orange tab as you insert the wire through the pin slot Device Pin Mapping Instructions Audio Output AO GND Connect the wires of the audio out...

Страница 25: ...GND GROUND PIN TX D TX DATA TX D TX DATA Via RS 422 Connection Pin Label Camera Serial Device Rx RX TX RX RX TX GND GROUND PIN TX TX RX TX TX RX NOTE The pins of the serial device may be labeled diffe...

Страница 26: ...d slot until it clicks into place Once inserted make sure to access the camera Web Configurator and mount the card to prepare the card for local recording Refer to the camera Firmware User s Manual fo...

Страница 27: ...d the PC would request a unique IP address from the DHCP server automatically In such case the camera will immediately be ready for the access from the PC The user however might not know the IP addres...

Страница 28: ...ial numbers firmware versions etc and allows quick configuration of multiple devices at the same time Search and downloand IP Utility for free from http www acti com DownloadCenter When you launch IP...

Страница 29: ...o the network and it does not detect any DHCP services it will automatically assign itself a default IP 192 168 0 100 Whereas the default port number would be 80 In order to access that camera the IP...

Страница 30: ...IP Utility With the procedure shown above all the cameras will have unique IP addresses starting from 192 168 0 101 In case there are 20 cameras selected the last one of the cameras would have the IP...

Страница 31: ...ion Detection regions Privacy Mask regions Yes All the other configurations Yes When using Internet Explorer browser the ActiveX control for video stream management will be downloaded from the camera...

Страница 32: ...in page The HTTP port number was not added behind the IP address since the default HTTP port of the camera is 80 which can be omitted from the address for convenience Before logging in you need to kno...

Страница 33: ...Copyright 2017 ACTi Corporation All Rights Reserved 7F No 1 Alley 20 Lane 407 Sec 2 Ti Ding Blvd Neihu District Taipei Taiwan 114 R O C TEL 886 2 2656 2588 FAX 886 2 2656 2599 Email sales acti com...

Отзывы: