Acson Water Source Single Split (AWSS) system is one of the most efficient and high performance systems that
can move energy in a building from where it is not needed to where it is needed. It is perfect for buildings that
required heating and cooling operation at different zones. With this, different areas or zones can be heated or
cooled at different temperature simultaneously. The heat is rejected and added in a water loop using a cooling
tower and a boiler. The units are easy to install, operate and maintain.
Energy Saving
AWSS is the most efficient system available for heating and cooling. It will be very cost effective for seasonal
operation and can provide greater indoor comfort to the occupants. With the lower power consumption, the
operation and maintenance cost is very much lower than the conventional air-conditioning systems.
Easy Installation and Improve Aesthetics
The unit has a great flexibility for installation. With a compact design and a low height profile, it can easily fit the
required space layout and allow maximum use of space. The units are concealed from the occupant views as
the units are installed above the ceiling and are sheltered inside the building. The units are painted as well. It will
improve the aesthetics value of a particular building and eliminates the probability of vandalism and injury.
Quiet Operation
AWSS is developed with double isolation panel (Upper and Lower Panel). Such design has promised the
extremely low vibration on the unit itself. Moreover, the heavy gauge cabinet construction together with vibration
isolated hanger brackets also minimizes noise and vibration effectively.
Easy Servicing and Maintenance
The two side removable service panels provide easy access to the compressor as well as the heat
exchanger.
Fluid-to-Refrigerant Coil
The tube-in-tube coaxial heat exchanger applied in AWSS unit is designed for maximum heat transfer at normal
and low water flow rate with minimum pressure drop. The inside refrigerant tube is deeply fluted to enhance
heat transfer and minimize fouling. This coaxial heat exchanger is tested perfectly to 1600 psig on the water
side and refrigerant side.
Compressor
AWSS unit is designed around the most advanced compressors in the industry.
The rotary compressor (for sizes 2.37kW to 8.94kW) and scroll compressor (for sizes 11.58kW to 15.77kW)
give a quite and reliable performance over a wide operating temperature range.
Thermal Expansion Valve (TXV)
AWSS unit (for sizes 8.94kW to 15.77kW) is included with a thermal expansion valve for refrigerant metering.
It can precisely control the exact amount of refrigerant flow through the system to deliver rated cooling and
heating capacity.
2. FEATURES
Содержание AWSS30A
Страница 1: ...Technical Manual WATER COOLED SINGLE SPLIT AWSS30A AWSS40A AWSS50A AWSS60A...
Страница 13: ...13 Refrigerant Circuit Diagrams Model AWSS 30 40 50 60A...
Страница 63: ...107 Indoor Unit MODEL ACC30C Outdoor Unit MODEL AWSS30A 10 WIRING DIAGRAMS...
Страница 64: ...108 Indoor Unit Model ACC40 50 60C Outdoor Unit Model AWSS40 50 60A...
Страница 65: ...110 Indoor Unit Model ACK30A Outdoor Unit MODEL AWSS30A...
Страница 66: ...111 Indoor Unit Model ACK40 50A Outdoor Unit MODEL AWSS40 50A...