56
G8 REMOTE CONTROLLER
1. Transmission source
•
The source where the signal will be transmitted.
2. Signal Transmission indication
•
Blink to confirm the last setting has been send to
the unit.
3. On/Off Button
•
Press once to start the air conditioner.
•
Press again to stop the unit.
4. Temperature setting
•
To set the desired room temperature, press the
button to increase or decrease the set temperature.
•
The temperature setting range is from 16°C to
30°C (Optional setting 18°C to 30°C).
•
Press both buttons simultaneously to toggle the
temperature setting between °C and °F.
5. Operation mode
•
Press the MODE button to select the type of
operating mode.
•
For cooling only unit, the available modes are :
COOL, DRY & FAN.
•
For heat pump unit, the available modes are :
AUTO, COOL, BRY, FAN & HEAT.
6. Fan speed selection
•
Press the button until the desired fan speed is
achieved.
7. ON timer setting
•
Press the SET button will activate the on timer
function.
•
Set the desired on time by pressing the SET button
continuously. If the timer is set to 7.30am, the air
conditioner will turn on at 7.30am sharp.
•
Press the CLR button to cancel the on timer
setting.
8. OFF timer setting
•
Press the SET button will activate the off timer
function.
•
Set the desired off time by pressing the SET button
continuously.
•
Press the CLR button to cancel the off timer
setting.
9. Automatic air swing
•
Press the SWING button to activate the automatic
air swing function.
•
To distribute the air to a specific direction, press
the SWING button and wait until the louver move to
the desired direction and press the button once
again.
10. Sleep mode setting
•
Press the button to activate sleep mode. This
function is available under COOL, HEAT & AUTO
mode.
•
When it is activated in COOL mode, the set
temperature will be increased 0.5°C after 30mins,
1°C after 1 hour and 2°C after 2 hours.
•
When it is activated in HEAT mode, the set
temperature will be decreased 1°C after 30mins,
2°C after 1 hour and 3°C after 2 hours.
11. Clock time setting
•
Press or – to increase or decrease the
clock time.
12. Turbo function (optional)
•
Press button for fast cooling or heating operation.
•
The temperature will be increased internally if it is
in the HEAT mode, decreased if in COOL or DRY
mode. Fan speed will be increased if it is not at
maximum speed.
•
The temperature & fan speed will resume to user
setting if the button is pressed again or after
20mins.
•
Available under HEAT, COOL & DRY modes only.
1
2
3
4
5
6
7
8
9
10
11
12
Содержание A4LC 20B
Страница 15: ...14 OUTDOOR UNIT ALC 30 40 50C CR A4LC 30 40 50 C CR...
Страница 16: ...15 INDOOR UNIT COOLING ONLY MODEL ACK 20 25A C3A BOARD 7 WIRING DIAGRAMS OUTDOOR UNIT MODEL ALC A4LC 20 25B...
Страница 17: ...16 INDOOR UNIT COOLING ONLY MODEL ACK 30A C3A BOARD OUTDOOR UNIT MODEL ALC A4LC 30C...
Страница 18: ...17 INDOOR UNIT COOLING ONLY MODEL ACK 40 50A C3A BOARD OUTDOOR UNIT MODEL ALC A4LC 40 50C...
Страница 19: ...18 INDOOR UNIT HEAT PUMP MODEL ACK 20 25AR C3A BOARD OUTDOOR UNIT MODEL ALC A4LC 20 25BR...
Страница 20: ...19 INDOOR UNIT HEAT PUMP MODEL ACK 30AR C3A BOARD OUTDOOR UNIT MODEL ALC A4LC 30CR...
Страница 21: ...20 INDOOR UNIT HEAT PUMP MODEL ACK 40 50AR C3A BOARD OUTDOOR UNIT MODEL ALC A4LC 40 50CR...
Страница 22: ...21 INDOOR UNIT COOLING ONLY MODEL ACK 20 25A UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC A4LC 20 25B...
Страница 23: ...22 INDOOR UNIT COOLING ONLY MODEL ACK 30A UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC A4LC 30C...
Страница 24: ...23 INDOOR UNIT COOLING ONLY MODEL ACK 30A UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC 30B...
Страница 25: ...24 INDOOR UNIT COOLING ONLY MODEL ACK 40 50A UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC A4LC 40 50C...
Страница 26: ...25 INDOOR UNIT HEAT PUMP MODEL ACK 20 25AR UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC A4LC 20 25BR...
Страница 27: ...26 INDOOR UNIT HEAT PUMP MODEL ACK 30AR UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC A4LC 30CR...
Страница 28: ...27 INDOOR UNIT HEAT PUMP MODEL ACK 40 50AR UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC A4LC 40 50CR...
Страница 29: ...28 INDOOR UNIT COOLING ONLY MODEL ACK 15B UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC15B...
Страница 30: ...29 INDOOR UNIT COOLING ONLY MODEL ACK 20 25B UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC20 25B...
Страница 31: ...30 INDOOR UNIT COOLING ONLY MODEL ACK 30B UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC30C...
Страница 32: ...31 INDOOR UNIT COOLING ONLY MODEL ACK 30B UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC 30B...
Страница 33: ...32 INDOOR UNIT HEAT PUMP MODEL ACK 15BR UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC 15BR...
Страница 34: ...33 INDOOR UNIT HEAT PUMP MODEL ACK 20 25BR UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC 20 25BR...
Страница 35: ...34 INDOOR UNIT HEAT PUMP MODEL ACK 30BR UNIVERSAL BOARD OUTDOOR UNIT MODEL ALC 30CR...
Страница 38: ...37 MODEL ALC 20 25BR HEAT PUMP 3 PHASE 50HZ 380 415V MODEL ALC 30CR HEAT PUMP 3 PHASE 50HZ 380 415V...
Страница 41: ...40 LOW AMBIENT UNIT OPTIONAL OUTDOOR UNIT MODEL ALC 10B 15B 50HZ OUTDOOR UNIT MODEL ALC 20B 25B 50HZ...