YELLOW
GREEN
SWITCH SLIDER
FAIL SECURE
ELECTRIC TRIM CONTROL INSTRUCTIONS
MOTOR-CONTROLLED ELECTRIC LOCKING/UNLOCKING
Electrical Specifications:
Voltage: 12-24V AC/DC (11V - 30V)
Current: 250mA MAX Inrush, 10mA MAX Holding
Non-polarized Leads
1560 - Fail Safe (Power Lock):
Outside trim is locked when power is applied and unlocked when power is removed.
Trim control will unlock in the event of a power failure.
1570 - Fail Secure (Power Unlock):
Outside trim is unlocked when power is applied and locked when power is removed.
Trim control will lock in the event of a power failure.
Key Function:
The outside trim may be momentarily unlocked with a
key even though the trim control is electrically locked.
Switch Slider Settings:
Yellow: Fail Secure
Green: Fail Safe
Note: Power must be applied to the trim control after a switch slider setting change.
HAGER 45CE
FAIL SAFE
2-Conductor Wire Run
Distance
12V/24V
Wire Gauge
125'/250'
22
200'/400'
20
300'/600'
18
500'/1000'
16
750'/1500'
14
1250'/2500'
12
2720 CLARK AVE. ~ ST. LOUIS, MO 63103 ~ 1-800-753-5558 ~ www.acsi-inc.com
II-E1500-45