7. Maintenance 

The device is free of maintenance. 

 

Battery exchange 

Dependent on environmental conditions e.g. network strength or temperature and also highly depending on 
the settings like e.g. standby time or frequency of data transmission the inserted battery is differently 
discharged. 

 

Completely it is possible, each for itself, to send about 3000 SMS or to carry out about 400 data transmission 
with a data amount of respectively 128kB or to achieve about 400 hours standby time with one lithium 
battery. 

 

A typically run time of 2 years can be achieved e.g.: 

at a daily standby time once a day for a half hour, or 
at a daily data transmission of a fully stored water level sensor  

  

 

 

 

 

 

 

 

 

     

with 128kB memory volume and a measuring interval of 

 4 seconds 

 

A typically run time of more than 10 years can be achieved e.g.: 

if the RDT module is only used for rare alarming cases, or 
at a monthly transmission of the data of a water level sensor  

  

 

 

 

 

 

 

 

 

 

 

    

with 128kB memory volume and a measuring interval or 

 2 minutes 

 

The remaining battery capacity is measured internal in the device and is compared with the set available 
battery capacity of the inserted lithium battery. At an adjustable remaining battery capacity a warning 
message can be sent. It is suggested to change the battery at a remaining battery capacity lower than 30% 
in order to guarantee always a sufficient safety function. After a battery change the battery counter must be 
reset by using the operation software in order to have a correct remaining battery capacity measurement. If 
the reset of the battery counter will not be done, a warning message can be generated, although the inserted 
battery has enough remaining capacity. 
If a lithium battery with a capacity is used that differs from the suggested standard battery, the capacity of 
the alternative type can be set by the operation software. 

 

After a long inactive time of the RDT module without resp. with an unloaded battery it can last up to 60 
minutes after inserting a new battery before a GSM/GPRS RDT is already possible, because the internal 
energy buffer (power buffer) must be reloaded. 
The communication per PC interface is immediately functional after inserting a new battery. 

 

For a battery exchange proceed like follows: 
 
 
 

Screw completely off the cover of the battery receptacle at the 
bottom side of the filler cap counterclockwise 

(image 1).

 

 
Remove the old battery by pulling out 

(image 2)

.

 

 
 
 
 
 
 
 
Put the new battery with the positive pole right into the 
battery receptacle (

image 3

). The battery connection is 

reverse polarity protected. 
 
Screw-in in the cover of the battery receptacle clockwise till to 
the stop (

image 4

). 

 
 
 
When opening the cover of the battery receptacle the wasting 
of the internal area of the device with humidity or dirt.  
This can lead to abnormal behavior, reduced run time or 
destruction of the device. 

 

image 1 

image 2 

image 3 

+pole 

image 4 

Содержание GSM-3000

Страница 1: ...y GPRS to FTP server Quad band compatible for the worldwide use in mobile telephony network Remote alarming to PC or mobile phone Integrated battery for run times of more than 5 years Connection of wa...

Страница 2: ...the office resp the operation forces in the case of alarming Dependent on the configuration of the RDT module different functions are possible These are e g the transmission of alarming messages per...

Страница 3: ...ng of mobile phones is not allowed e g in hospitals or explosive hazardous areas Electromagnetically sensitive devices can be interfered in their operation because of the high energetic radio waves at...

Страница 4: ...e carried out by the RDT module This is not possible with an unloaded prepaid SIM card For using of SIM card the input of the correct PIN code by using the operation software is necessary Without thes...

Страница 5: ...t at removed plug the protection cap must be fully inserted into the socket Connecting a sensor For a complete measuring system with RDT the connection of a water level sensor to the RDT module is nec...

Страница 6: ...r 20 cycles After opening the filler cap the RDT module requests at first all relevant data s from the connected water level sensor Getting Data Please wait Name Donau 1 Measure Value 3 459 mwc Batter...

Страница 7: ...t By setting a daily standby time of 2 minutes every day at 8 00 o clock the RDT module log on every day at 8 00 o clock to the GSM network at the respective provider and checks if new SMS messages ar...

Страница 8: ...resp FTP resp SNTP 0 PC resp FTP data transmission resp internet time synchronization off no state SMS 1 PC resp FTP data transmission resp internet time synchronization on send state SMS The respons...

Страница 9: ...irmed Example 4 The password of the RDT module is 123456789 The module should be set to an enforced standby mode for 2 hours 120 minutes The state SMS should be sent SMS message 123456789 SFSB 120 CSS...

Страница 10: ...y alarm GSBP get standby prealarm GGPW get RDT module password GHPW get water level sensor password GST1 get status text 1 GST2 get status text 2 GLBT get low battery text GUPOT get upper prealarm ove...

Страница 11: ...N8 set 8th telephone number SASI set alarm SMS interval in minutes STNS1 set telephone number status 1 STNS2 set telephone number status 2 STNSC set telephone number service center STNP1 set 1st telep...

Страница 12: ...TP server address SFTPU set FTP server user name SFTPP set FTP server password SFTPD set FTP server directory SFAI set FTP alarm interval in minutes SCDF set CSV date format SCTF set CSV time format S...

Страница 13: ...remaining battery capacity lower than 30 in order to guarantee always a sufficient safety function After a battery change the battery counter must be reset by using the operation software in order to...

Страница 14: ...tion The chemical and physical characteristics of the product A short description of the occurred error Before returning the device for repair the following measures must be proceeded All stick produc...

Страница 15: ...00 Baud Interface Water level sensor Type RS485 full duplex Transmission rate 9600 Baud Clock Type Real time clock Cycle accuracy 1 minute month Materials Filler cap Aluminum powder coated Module hous...

Страница 16: ...GSM 3000 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem de info acs controlsystem de 16 10 Dimension drawings...

Страница 17: ...ter level tube 4 ISO 228 1 DIN 259 412 Filler cap for installation on water level tube G 4 ISO 228 1 DIN 259 500 Filler cap for installation on water level tube G 5 ISO 228 1 DIN 259 600 Filler cap fo...

Страница 18: ...GSM 3000 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem de info acs controlsystem de 18...

Отзывы: