8.1.8.
CCID Bulk-IN Messages
The Bulk-IN messages are used in response to the Bulk-OUT messages. ACR38x (CCID) shall follow
the CCID Bulk-IN Messages as specified in section 4. This section lists the CCID Bulk-IN Messages
to be supported by ACR38x (CCID).
8.1.9.
RDR_to_PC_DataBlock
This message is sent by ACR38x (CCID) in response to
PC_to_RDR_IccPowerOn
,
PC_to_RDR_XfrBlock
and
PC_to_RDR_Secure
messages.
Offset
Field
Size
Value
Description
0
bMessageType
1
80h
Indicates that a data block is being sent from
the CCID
1
dwLength
4
Size of extra bytes of this message
5
bSlot
1
Same value as in Bulk-OUT message
6
bSeq
1
Same value as in Bulk-OUT message
7
bStatus
1
Slot status register as defined in CCID section
4.2.1
8
bError
1
Slot error register as defined in CCID section
4.2.1 and this specification section 5.2.8
9
bChainParameter
1
00h
RFU (TPDU exchange level)
10
abData
Byte
array
This field contains the data returned
by the CCID
8.1.10.
RDR_to_PC_SlotStatus
This message is sent by ACR38x (CCID) in response to
PC_to_RDR_IccPowerOff
,
PC_to_RDR_GetSlotStatus
,
PC_to_RDR_Abort
messages and Class specific ABORT request.
Offset
Field
Size
Value
Description
0
bMessageType
1
81h
1
dwLength
4
00000000h
Size of extra bytes of this message
5
bSlot
1
Same value as in Bulk-OUT message
6
bSeq
1
Same value as in Bulk-OUT message
7
bStatus
1
Slot status register as defined in CCID section
4.2.1
8
bError
1
Slot error register as defined in CCID section
4.2.1 and this specification section 5.2.8
9
bClockStatus
1
value =
00h
Clock running
01h
Clock stopped in state L
02h
Clock stopped in state H
03h
Clock stopped in an unknown state
All other values are RFU.