Document Title Here
Document Title Here
Document Title Here
ACR38x Reference Manual (CCID)
Version 6.02
Page 11 of 20
www.acs.com.hk
8.0. Commands
8.1. CCID Command Pipe Bulk-OUT Messages
The ACR38x (CCID) shall follow the CCID Bulk-OUT Messages as specified in CCID section 4. In
addition, this specification defines some extended commands for operating additional features. This
section lists the CCID Bulk-OUT Messages to be supported by ACR38x (CCID).
8.1.1.
PC_to_RDR_IccPowerOn
Activate the card slot and return ATR from the card.
Offset
Field
Size
Value
Description
0
bMessageType
1
62h
1
dwLength
4
00000000h
Size of extra bytes of this message
2
bSlot
1
Identifies the slot number for this command
5
bSeq
1
Sequence number for command
6
bPowerSelect
1
Voltage that is applied to the ICC
00h
– Automatic Voltage Selection
01h
– 5 volts
02h
– 3 volts
7
abRFU
2
Reserved for future use
The response to this message is the
RDR_to_PC_DataBlock
message and the data returned is the
Answer to Reset (ATR) data.
8.1.2.
PC_to_RDR_IccPowerOff
Deactivate the card slot.
Offset
Field
Size
Value
Description
0
bMessageType
1
63h
1
dwLength
4
00000000h
Size of extra bytes of this message
5
bSlot
1
Identifies the slot number for this command
6
bSeq
1
Sequence number for command
7
abRFU
3
Reserved for future use
The response to this message is the
RDR_to_PC_SlotStatus
message.