SAT
page 7 of 9
Technical data
Materials
Electrode rod:
Steel 1.4404 (AISI316L) resp. 1.4571 (AISI316Ti) / Hastelloy C22
(medium contact)
Electrode rod isolation:
PA / ETFE resp. E-CTFE
(medium contact)
Process connection:
POM / PP / PTFE
(medium contact)
Terminal enclosure:
POM / PP / PTFE
Cable gland:
Enclosure PA / gaskets CR, NBR
Gaskets:
Medium contact:
Electrode isolation PA
NBR
Electrode isolation
E-CTFE
FPM
Others: NBR, FPM
Environmental conditions
Environmental temperature:
maximum
– 15°C...+100°C, observe limitations
Limitation by variant
Environmental temperature range
ATEX zone 0
-15...+60°C
ATEX T6
-15...+80°C
ATEX T5…T1
-15...+95°C
Limitation by material
Environmental temperature range
Terminal enclosure PP
+5...+100°C
Process temperature:
maximum
– 15°C...+150°C, observe limitations
Limitation by variant
Process temperature range
ATEX zone 0
-15...+60°C
ATEX T6
-15...+80°C
ATEX T5
-15...+ 95°C
ATEX T4
-15...+ 130°C
ATEX T3...T1
-15...+ 130°C
Electrode isolation PA
-10...+ 100°C
Electrode isolation
ETFE resp. E-CTFE
-15...+ 150°C
Limitation by material
Process temperature range
Process connection POM
-15...+110°C
Process connection PP
+5...+100°C
Process pressure:
Standard
-1 bar...+10 bar
ATEX zone 0
+0,8 bar... +1,1 bar
Conductivity:
1 M
resp.
1 µS/cm, depends on connected evaluation device
Protection classification:
IP65
EN/IEC 60529
Weight:
Depends on:
-
material / size of connection housing resp.
-
style of process connection resp.
-
material / diameter / number / length of the electrodes