background image

ATR480 Time Recorder

 | 

User’s Manual

 

6

 

Code 03:  Pay Period Setting 

Press ‘ + ‘ or ‘ – ‘ to select the pay period setting 

Select ‘ 01 ‘ for  a weekly pay period 

Select ‘ 02 ‘ for a bi-weekly pay period 

Select ‘ 03 ‘ for a semi-monthly pay period 

Select ‘ 04 ‘ for a monthly pay period 

Select ‘ 05 ‘ for work mode / no pay period setting 

Press ‘ Enter ‘ to confirm the selection 

 

Code 04:  Pay Period Cycle End 

For weekly 

Press ‘ + ‘ or ‘ – ‘ to select the day of the week 

Select ‘ 00 ‘ for Sunday 

Select ‘ 01 ‘ for Monday 

Select ‘ 02 ‘ for Tuesday 

Select ‘ 03 ‘ for Wednesday 

Select ‘ 04 ‘ for Thursday 

Select ‘ 05 ‘ for Friday 

Select ‘ 06 ‘ for Saturday 

Press ‘ Enter ‘ to confirm the selection 

For Bi-weekly 

Press ‘ + ‘ or ‘ – ‘ to select start month 

Press ‘ Enter ‘ to confirm the selection 

Press ‘ + ‘ or ‘ – ‘ to select start day 

Press ‘ Enter ‘ to confirm the selection 

For Semi-monthly 

Press ‘ + ‘ or ‘ – ‘ to select days of the month 

Select ‘ 00 ‘ to use the 15

th

 day and the last day 

Select ‘ 01 ‘ to use the 14

th

 day and the 2

nd

 to the last day 

Select ‘ 02 ‘ to use the 13

th

 day and the 3

rd

 to the last day 

Select ‘ 03 ‘ to use the 12

th

 day and the 4

th

 to the last day 

Select ‘ 04 ‘ to use the 11

th

 day and the 5

th

 to the last day 

Select ‘ 05 ‘ to use the 10

th

 day and the 6

th

 to the last day 

Select ‘ 06 ‘ to use the 1

st

 day and 16

th

 day 

Press ‘ Enter ‘ to confirm the selection 

Содержание ATR480

Страница 1: ...User Manual Top Loading Totalizing Time Recorder ATR480 Disponible en fran ais https www acroprint com resources user manuals...

Страница 2: ...ircumstances attempt to release the lithium battery in the clock Failure to comply may void your warranty Any attempt to do so must be performed by qualified personnel wearing appropriate eye protecti...

Страница 3: ...ht Savings Start Time 4 Code 08 Daylight Savings End Date 4 Code 09 Daylight Savings End Time 4 Code 10 Vertical Alignment 5 Code 11 Horizontal Alignment 5 Code 12 Card Side Identification 5 Pay Perio...

Страница 4: ...4 10 Code 01 24 Change Schedule 10 Setting 1 Hour 10 Setting 2 Minute 10 Setting 3 Days 10 Setting 4 Color 10 Set Password Mode ES05 11 Code 01 Enable or Disable Password 11 Code 02 Set Password 11 Me...

Страница 5: ...e Recorder User s Manual Appendix 20 Changing the Clock Ribbon 20 Ribbon Life 20 Cleaning the Clock 20 Operational Battery Pack 21 Connecting External Signal Devices Bells Horns 21 Wall Mounting Instr...

Страница 6: ...ems are found missing and or damaged kindly contact Customer Support immediately Bundled Product Contents ATR480 Time Clock with Operational Backup Battery Installed 4 Clock Cover Keys on Key Ring 12...

Страница 7: ...operate under relative humidity of 10 60 The clock may be placed upright on a solid surface or mounted to a wall using the provided mounting screws Avoid places where the device is susceptible to vibr...

Страница 8: ...Mode You will need to enter your password to access the clock menus If you misplace your password you will need to contact Acroprint at 800 334 7190 for assistance to reset your password Time Date Set...

Страница 9: ...setting Press Enter to confirm the selection Code 07 Daylight Savings Start Time Press or to increase or decrease the hour setting Press Enter to confirm the selection Press or to increase or decreas...

Страница 10: ...back identification Select 00 to disable the feature Select 01 to enable the feature Press Enter to confirm the selection Note Items marked with are hidden and can be accessed by pressing the 3rd and...

Страница 11: ...for Thursday Select 05 for Friday Select 06 for Saturday Press Enter to confirm the selection For Bi weekly Press or to select start month Press Enter to confirm the selection Press or to select start...

Страница 12: ...rounding by five minutes Select 10 for rounding by ten minutes Select 15 for rounding by fifteen minutes Press Enter to confirm the selection Code 06 Fixed Deduction Rule Start Press or to increase or...

Страница 13: ...entering programming mode Code 00 Alarm Duration Press or to increase or decrease the duration of the alarm Press Enter to confirm the selection Code 01 24 Alarm Schedule There are four settings to be...

Страница 14: ...the right enter ES03 mode to begin Press Enter when ES03 appears on the screen when entering programming mode Code 01 12 Column Shift Schedule There are three settings to be set for each code Once all...

Страница 15: ...will increase by one and another set can be confirmed Setting 1 Hour Press or to set the hour of the day for the change Press Enter to confirm the selection Setting 2 Minute Press or to set the minute...

Страница 16: ...Press or to adjust the 1st password entry Press Enter to confirm the selection Press or to adjust the 2nd password entry Press Enter to confirm the selection Press or to adjust the 3rd password entry...

Страница 17: ...ht Savings Start Date Default 03 13 07 Daylight Savings Start Time Default 02 00 AM 08 Daylight Savings End Date Default 11 06 09 Daylight Savings End Time Default 02 00 AM 10 Vertical Alignment Moves...

Страница 18: ...pute total hours Weekly 00 01 06 Sunday Monday Saturday Bi weekly Select starting date Semi monthly 00 01 02 05 06 15th last day 14th last day 1 13th last day 2 10th last day 5 16th 1st 04 Pay Period...

Страница 19: ...vertime Start Weekly 00 168 hours after first punch Default set to 00 for no deductions 10 Maximum Work Hours 00 24 maximum allowed recorded hours per day Options 004 010 are hidden when Work Mode is...

Страница 20: ...ns next set at Set Schedule Mode ES03 is made available only if Work mode is used Mode ES04 Automatic Color Schemes Mode ES04 Enter Set Color 01 02 Red Black Set Schedule for Color Implementation 1st...

Страница 21: ...column and color settings Holding down the 5th and 6th keys will clear the punch ins recorded in the unit s memory Holding down the 3rd and 4th keys while under Mode ES00 three more options will be m...

Страница 22: ...ixed Deduction Minutes Overtime Start Daily Overtime Start Weekly Maximum Work Hours ES02 Alarm Settings Up to 24 Sets Alarm Duration Alarm Time Alarm Days ES03 Automatic Column Shifting Up to 12 Sets...

Страница 23: ...he print to match the card 11 Adjusting the horizontal alignment of the print to match the card 12 Allows Prevents printing on the wrong side of the card when applicable Mode ES01 Code Function 01 Adj...

Страница 24: ...Adjusting the hour when the column shifts Adjusting the minute when the column shifts 01 12 Adjusting the days where the rules are implemented Mode ES04 Code Function Adjusting the hour when the color...

Страница 25: ...ween the guide and the silver print shield Push the ribbon down until it clicks into place If it doesn t click into place turn the ribbon winding knob clockwise to finish seating the cassette and to r...

Страница 26: ...the clock is running on battery power in order to save power however the LCD display is plainly visible in a lighted room Battery Pack Specs Voltage DC 10 8v Capacity 800mAh The ATR480 should be plugg...

Страница 27: ...mation about connecting an external signal device using a relay go to http support acroprint com Under Time Clocks Document Stamps click on ATR480 Time Clock in the drop down menu and download 06 0346...

Страница 28: ...ATR480 Time Recorder User s Manual 23 06 0442 000 Rev B...

Отзывы: