background image

Page 8 

Ribbon Life 

The ATR242 ribbon (39-0135-000) will typically last 3 months with 50 employees 
punching 6 times per day (~18,000 punches).  Actual ribbon life will vary based on the 
number of punches, humidity, temperature, exposure to air. 

 

 

Operational Battery Pack 

The optional operational battery pack (58-0114-000) is a 12 cell NiMH (Nickel Metal 
Hydride) battery pack that recharges when the ATR240 is plugged in.    In the event of a 
power failure the clock will instantly switch to battery power without any interruption in 
service.    The operational battery pack allows for full operation of the clock.    The LCD 
backlight is not activated when the clock is running on battery power as a power saving 
feature, however the

 

LCD display is plainly visible in a lighted room. 

 
Battery Pack Specs: 

Voltage:  DC 14.4v 
Capacity:  1800mA 
Standby mode: 30-36hr reserve power 
Fully charged: 5 days use (300 punches/day) 

Note: Actual battery life depends on many factors such as battery age, temperature, 
discharge history, etc., and can vary greatly depending on these factors. 

The ATR240 should be plugged in for 12 hours to fully charge the battery pack. 

For more information see

 “

Installing the Operational Battery Pack” in the Appendix. 

 

Warning: 

Batteries may leak, overheat, catch fire or explode if proper safety & handling procedures 
are not followed: 

 

DO NOT get batteries wet 

 

DO NOT place batteries near heat sources 

 

DO NOT use any power supply other than the             

          original one supplied with the time recorder. 

 

DO NOT inverse polarity connection 

 

NEVER throw batteries into fire. Properly dispose of 

       batteries according to local rules and regulations. 

 

DO NOT allow anything to short circuit the batteries 

 

Dropping a battery may damage the battery.       

  Replace the battery if you suspect any damage. 

 

 

Internal View 

(Internal Control Panel) 
 

 
 
 

Содержание ATR240

Страница 1: ...ATR240 User Manual Top Loading Time Card Recorder...

Страница 2: ...ur warranty Battery replacement should be done by qualified personnel wearing the proper eye protection CAUTION Danger of explosion if the battery is incorrectly replaced Replace only with the same or...

Страница 3: ...8 Internal View 8 Re setting Time Recorder to Factory Defaults 9 Troubleshooting 9 Frequently Asked Questions 10 Maintenance 11 Replacing the Ribbon Cassette 11 Replacing the Circuit Board Batteries...

Страница 4: ...int Customer Service at 800 334 7190 3 Connect the ATR240 power adapter and plug it into a wall outlet to turn the clock on Do not attempt to service the ATR240 yourself Disassembling the clock will v...

Страница 5: ...07 Sun 01 07 07 Clock Display Format 12 or 24 Hr 12 08 Adjust Printing Position Max 6mm Vert Horiz adj Increase s to move up right 00 15 Vertical Axis 00 30 Horiz Axis 08 08 vert horiz 09 DST Start Mo...

Страница 6: ...Clock Overview Top View Front View Battery Status Indicator A fully charged Battery will have 5 bars DST Icon displays when exiting programming mode when DST is turned on Each blink of the colon is o...

Страница 7: ...Page 4 Rear View...

Страница 8: ...e 9 Press P4 or P5 to select the current date 10 Press P6 to save Setting Time 11 The mode indicator 3 will be flashing press P6 to select 12 Press P4 or P5 to select the current hour 13 Press P6 to s...

Страница 9: ...date 32 Press P6 to save 33 Press P4 or P5 to select the correct start time US 2am 34 Press P6 to save 35 Complete steps 29 34 to complete the set up for the end of DST Setting Print Format 36 The mod...

Страница 10: ...n Available Auto Column Changing Yes Compatible with Wkly Time Card Yes Card Recognition Off Card Recognition front back Yes Clock Specifications Miscellaneous Input Voltage DC 18v Input Current 1 5A...

Страница 11: ...4v Capacity 1800mA Standby mode 30 36hr reserve power Fully charged 5 days use 300 punches day Note Actual battery life depends on many factors such as battery age temperature discharge history etc a...

Страница 12: ...e was not set correctly Prolonged power outage Set correct time Set time after power is restored The clock keeps losing time The coin cell battery on the motherboard needs to be replaced Replace the c...

Страница 13: ...n will not advance remove cassette and try advancing again If ribbon won t advance replace ribbon Frequently Asked Questions 1 Q The display does not work or parts of it do not work A Possible Causes...

Страница 14: ...3 to move the print head to the center of the clock so that the ribbon cassette can be more easily accessed 2 Pull the ribbon holder tabs towards you to unlock the ribbon cassette and use the handle o...

Страница 15: ...any components on the circuit board Avoid using metal objects to remove the batteries Note all Time Recorder settings will be reset to factory defaults as soon as the Main board battery is removed Bac...

Страница 16: ...o the clock with the wires inserted into the opening in the side of the compartment This is important since the battery door can t be attached if the battery is sitting on top of the wires You may nee...

Страница 17: ...a relay is required Please call Acroprint or your Dealer to order the relay PN 01 0230 000 When a signal is activated by the clock the internal contacts of the relay close and complete the circuit Th...

Страница 18: ...nual available on web 06 0400 001 ATR240 User Manual available on web 06 0401 000 Mounting Template available on web 09 7000 000 ATR241 Weekly Time Card pack of 250 09 7001 000 ATR241 Monthly Time Car...

Страница 19: ...ject to misuse abuse negligence accidents power surges and lightning The guarantee is not applicable if the serial number has been altered defaced or removed or if the device has been tampered with or...

Страница 20: ..._____________ Email Address____________________________________________________ So that we may serve you better please indicate your primary business activity 01 Manufacturing 04 Government 02 Wholesa...

Страница 21: ...06 0400 001 Rev C...

Отзывы: