Page 13
Installing the Operational Battery Pack
First unplug the clock. The door to the battery pack compartment is located on the
bottom edge of the back of the clock. Remove the screw that secures the door. The
door may be tightly fitted. Insert a thin knife blade under the bottom of the door at the
screw end and rotate the blade to open the door.
Insert Blade Here
Connect the battery cable to the connector on the left side of the compartment. Note that
the two ridges on the side of the battery connector should be facing down to line up with
the slots in the clock’s power connector. Turn the battery so that the cable connection is
on the bottom. Insert the battery pack into the clock with the wires inserted into the
opening in the side of the compartment. This is important since the battery door can’t be
attached if the battery is sitting on top of the wires. You may need to use something like
a pencil or ruler to push the wires into the opening. Attach the door by inserting the door
tabs into the left side of the compartment and firmly rotating the door into place. If the
door won’t close check to make sure the wires aren’t under the battery. Plug in the
power supply once the battery door is secure. The ATR240 should be plugged in for 12
hours to fully charge the battery pack.
Cleaning the ATR240
Do not use cleaning products that contain alcohol or other strong chemicals as they could
discolor or crack the terminal housing. Use a soft damp cloth to remove dirt. Wipe dry.