Cleaning and Servicing
Deposits and residual adhesive on the transport rollers can influence the re-
sults of the laminating process. Therefore, the transport rollers must be
cleaned periodically after use:
To do this, insert a folded piece of paper in the insertion slot. Residual adhe-
sive is removed and taken up by the paper when ejected. Repeat the proc-
ess several times.
Disconnect the power plug before starting to clean the unit with a damp cloth.
If necessary, the housing can be cleaned using a cloth moistened with clean
water with a little mild soap applied. Never use any solvents or aggressive
cleaning agents.
Troubleshooting
Fault
Corrective measures
•
Red LED (POWER) does not light
up
•
Unit does not respond
•
Check that the power plug has
been properly connected to the
power socket.
•
If the fault cannot be cleared, con-
tact our hotline.
•
Foil jam
•
Check the foil pockets being used
are the correct size.
•
Only use pouches of the size speci-
fied.
•
Ensure that the pouch has been in-
serted correctly in the unit.
•
To clear the fault, follow the instruc-
tions in the Section "Clearing Foil
Jams".
•
Laminated foil is not completely
transparent
•
Laminate the same foil again to im-
prove the lamination result.
Conformity of the equipment to the
EU directives is confirmed by the
CE symbol.
Disposal Notes
This symbol [the crossed-out wheeled bin/PICTURE] means that
the product should be brought to the return and or separate
collection systems available to end-users, when the product has