7.2 Hardware Information and Configuration
7.2.1 Switch SW1 Configuration
Table 7.2.1.a summarizes the functions, settings, and descriptions for dip
switch SW1.
Table 7.2.a: XBRD-9060 Configuration Switch SW1
Configuration Switch SW1
Position
Function
Switch Setting
Description
1-3
Ethernet Port
Enable
1-2
Front Panel Ethernet
Port Enabled
2-3
Front Panel Ethernet
Port Disabled
4-6
ORB GND
4-5
ORB GND tied to Digital
GND
5-6
ORB GND Isolated
SW1:1-3 is used to configure the front panel Ethernet port. When this port
is enabled the ETH1 signals are not available on the XVME-6700A's P0
connector.
SW1:4-6 is used to configure the isolation of the Front Panel (ORB) GND.
7.3 mSATA Module Installation
One or two full-size (51mm) mSATA modules may be installed by using the
screws provided. In a high-vibration environment the addition of a
removable thread locker, such as Loctite 242, is recommended. For
installation of half-size (26.8mm) mSATA modules please consult factory.
7. 4 Installation onto XVME-6700A
The XBRD-9060 is installed onto the XVME-6700A in the same fashion as a
PMC/XMC module. First insert the XBRD-9060 through the front panel at an
angle, and then bring the back of the module down to seat into the
expansion connector. Once the module is seated in the connector, install
the four screws provided from the back side of the XVME-6700A.
In a high-vibration environment the addition of a removable thread locker,
such as Loctite 242, is recommended.