User's Manual:  SmartPack Series 550L

Model EP4994 Quad VDC Input DC-Powered L

ON

W

ORKS

™ Module

Table of Contents

Page

Introduction

   1

Description

   1

Specifications

   2

Installation

   3

Network Variables

   4

Calibration

   6

General Maintenance

   7

List of Drawings

Electrical Connections: V/mA Inputs (4501-506)

   8

Dimensions: DIN Rail Mounting (4501-502)

   8

Calibration Connections (4501-508)

   9

Application Connections: Power Supply (4501-509)

   9

IMPORTANT SAFETY CONSIDERATIONS

It is very important for the user to consider the possible adverse
effects of power, wiring, component, sensor, or software failures
in designing any type of control or monitoring system.  This is
especially important where economic property loss or human life
is involved.  It is important that the user employ satisfactory
overall system design.  It is agreed between the Buyer and
Acromag, that this is the Buyer's responsibility.

Acromag, Inc.                                                 Tel: (248) 624-1541
30765 South Wixom Road                            FAX: (248) 624-9234
P.O. Box 437
Wixom, Michigan  48393-7037, USA

Copyright 1996, Acromag, Inc., Printed in the USA.
Data and specifications are subject to change without notice.
LON, Neuron, and LonTalk are U.S. registered trademarks of
Echelon Corporation.  L

ON

W

ORKS

 is a trademark of Echelon

Corporation.  Windows is a trademark of Microsoft Corporation.

9000-366/8500-526-C98A006

INTRODUCTION:

These instructions cover the model types listed in Table 1

below.  Supplementary sheets are attached for units with special
options or features.

Table 1:
A.  Model Number Format :
      550L1-Function-Input-Power-Certification
B.  Typical Model Number:  550L1-504-4V2-10-NCR

Series/
Network

-Function

-Inputs

-Power

-Cert.
   (1)

 -Cal.
   (2)

550L1

-504

-4V2

-10

-NCR

Blank
  -C

550L3

-504

-4V2

-10

-NCR

Blank
  -C

Notes (Table 1):
1.   Consult the factory for current information on agency (e.g.

Canadian Standards Association, etc.) approvals.

2.   Unit can be ordered with or without factory calibration;  if unit

is factory calibrated to a customer’s specifications, the model
number suffix “-C” will indicate this.  Any customer specified
calibration information will be included on a separate
calibration label on the unit.

DESCRIPTION:

The Series 550L is a member of the Acromag SmartPack

family.  It converts four independent DC voltage inputs into
corresponding network variables. The nominal input range for
each input is fixed at -10V to +10VDC, or -100V to +100VDC.
Through network variables, virtually any part of the input range
can be scaled to output values in the range of -100% to +100%,
as defined by the SNVT_lev_percent network variable type.  For
example, a 0 to 5 V input can be scaled to output 0 to 100%.  Or
a -75 to +75 V input can be scaled to output -100 to +100%. For
each analog input, network variable updates may occur due to
changes in input level and/or at specified time intervals.

All SmartPack modules are designed for harsh industrial

environments.  They feature RFI and EMI protection, a wide
operating temperature range, and isolation between power,
network and I/O.  They are DC powered, DIN-rail mountable, and
available with either a twisted pair (TP/XF-78) or free topology
(TP/FT-10) transceiver.  Up to 64 modules can be connected on
a single network segment.  Multiple segments may be connected
using repeaters to increase the number of modules and distance.

     retired

Содержание SmartPack EP4994

Страница 1: ...ower Certification B Typical Model Number 550L1 504 4V2 10 NCR Series Network Function Inputs Power Cert 1 Cal 2 550L1 504 4V2 10 NCR Blank C 550L3 504 4V2 10 NCR Blank C Notes Table 1 1 Consult the factory for current information on agency e g Canadian Standards Association etc approvals 2 Unit can be ordered with or without factory calibration if unit is factory calibrated to a customer s specif...

Страница 2: ...s section for a description of the module s standard network variable types and operation INPUT This unit has four independent analog inputs with software selectable output scaling ranges Zero and Full Scale calibration scaling of each input is done over the network Virtually any part of the input range can be scaled to output values in the range of 100 to 100 There are no potentiometers to adjust...

Страница 3: ...ith switching solenoids commutator and drill motors Surge Withstand Capability SWC Input Output terminations are rated per ANSI IEEE C37 90 1978 Unit is tested to a standardized test waveform that is representative of surges high frequency transient electrical interference observed in actual installations Mounting 0 Mounting General Purpose Housing with integrated DIN Rail Mount Supports G T rails...

Страница 4: ...gment 3 Grounding The module housing is plastic and does not require an earth ground connection 4 Input Connect input per connection diagram and observe proper polarity see label for input type If unit is factory calibrated the calibration label indicates range of input NOTE All inputs share a common however as a group they are electrically isolated from the network and power circuits allowing the...

Страница 5: ...D HH MM SS LL format is 00 03 38 27 000 Anything greater will be clipped at 00 03 38 27 000 To disable periodic updates set DD 65535 or all members to 0 This variable is maintained in EEPROM and does not take effect until the module is reset Initial Factory Value DD 65535 HH 00 MM 00 SS 00 LL 000 Periodic updates disabled nci_pvtime 4 Controls the update for nvo_struct_pvout output structure varia...

Страница 6: ...is 100 100 nvo_pvout VIN 60 x 100 20 60 This reduces to nvo_pvout VIN 60 x 2 5 100 CALIBRATION All modules are calibrated at the factory for an input range of 10VDC scaled to output 100 No additional calibration is normally required If it becomes necessary to calibrate the module follow the procedure outlined below for each analog input Values shown in parenthesis indicate the SNVT_lev_percent val...

Страница 7: ...ntenance except for periodic cleaning and calibration verification When a failure is suspected a convenient method for identifying a faulty module is to exchange it with a known good unit It is highly recommended that a non functioning module be returned to Acromag for repair since Acromag makes use of tested and burned in parts and in some cases parts that have been selected for characteristics b...

Страница 8: ...Series 550LX 504 4V2 10 SmartPack User s Manual Quad VDC Input __________________________________________________________________________________________ 8 ...

Страница 9: ...Series 550LX 504 4V2 10 SmartPack User s Manual Quad VDC Input __________________________________________________________________________________________ 9 ...

Страница 10: ...Series 550LX 504 4V2 10 SmartPack User s Manual Quad VDC Input __________________________________________________________________________________________ 10 ...

Страница 11: ...Series 550LX 504 4V2 10 SmartPack User s Manual Quad VDC Input __________________________________________________________________________________________ 11 ...

Страница 12: ...Series 550LX 504 4V2 10 SmartPack User s Manual Quad VDC Input __________________________________________________________________________________________ 12 ...

Отзывы: