SERIES AP48X ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 59 -
http://www.acromag.com
- 59 -
https://www.acromag.com
Note 1
: An air cooled application with an AcroPack module will
require a minimum airflow of 200LFM
.
Note 2
: Applications requiring operating temperatures of
70
o
C
to
85
o
C will require purchase of
AcroPack Heatsink Accessory
AP-CC-
01.
6.3.2 Other Environmental Requirements
6.3.2.1 Relative Humidity
The range of acceptable relative humidity is 5% to 95% non-condensing.
6.3.2.2 Isolation
The PCIe bus and field commons are non-isolated and have a direct electrical
connection.
6.3.3 Vibration and Shock Standards
The AcroPack is designed to pass the following Vibration and Shock
standards.
Vibration, Sinusoidal Operating:
Designed to comply with IEC 60068-
2-6: 10-500Hz, 5G, 2 Hours/axis
Vibration, Random Operating:
Designed to comply with IEC 60068-2-
64: 10-500Hz, 5G-rms, 2 Hours/axis
Shock, Operating:
Designed to comply with IEC 60068-2-27: 30G,
11ms half sine, 50G, 3mS half sine, 18 shocks at 6 orientations for
both test levels
6.3.4 EMC Directives
The AcroPack complies with EMC Directive 2004/108/EC.
•
Immunity per EN 61000-6-2:
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-3.
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
Surge Immunity, per IEC 61000-4-5.
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
•
Emissions per EN 61000-6-4:
Enclosure Port, per CISPR 16.
Low Voltage AC Mains Port, per CISPR 16.
Note:
This is a Class A product