ACPC4610E/CC User’s Manual                                  CompactPCI Bus PMC Carrier                                 
___________________________________________________________________ 

 

__________________________________________________________________________

 

Acromag, Inc.  Tel: 248-295-0310  Fax: 248-624-9234  Email:[email protected]  http://www.acromag.com 

3

 

The ACPC4610E/CC is a 3U CompactPCI Bus Non-Intelligent PMC 

carrier board designed for the 32-bit 33MHz or 66MHz CompactPCI bus.  
The carrier card uses a PLX Technology

R

 

Bridge Chip (PCI6540) to interface 

between the CompactPCI bus and one PMC mezzanine I/O module card. 

 
Model ACPC4610E is an air-cooled extended temperature product which 

can be used for front and rear PMC mezzanine I/O modules.  Front I/O can 
be accessed through the front panel.  Rear I/O can be accessed though the 
J2 connector on the carrier.  

  

 

ESD Strip on ACPC4610E Board

 - The ACPC4610E board has been 

designed to provide electrostatic discharge (ESD) capability by using an 
ESD strip on the board per IEEE1101.10. 

 

Injector/Ejector Handle

 - The ACPC4610E uses a modern 

injector/ejector handle, which pushes the board into the rack during 
installation and has a positive self-locking mechanism so it cannot be 
unlocked accidentally.  This handle is fully IEEE 1101.10 compliant and 
is needed to give leverage to install and remove the board. 

 

EMC Front Panel

 - The ACPC4610E uses the preferred EMC front 

panel per IEEE 1101.10 specification.  

 

Model ACPC4610CC is a conduction cooled product which is usually 

only used for rear Conduction Cooled PMC mezzanine I/O modules.  Rear 
I/O can be accessed though the J2 connector on the carrier. 

 

 

Conduction Cooled Frame

 - The ACPC4610CC board has a custom 

conduction cooled assembly consisting of a conduction cooled frame, 
thermo bars, ejector/injectors and Wedge-Loks

R

 designed to thermally 

conduct heat away from the Conduction Cooled PMC modules per 
ANSI/VITA 30.1-2001. 

 

Model TRANS-C4610 Transition Module:  This module plugs into the 

rear backplane directly behind the ACPC4610E carrier board.  The field I/O 
connections are made through the backplane to the J2 connector of the 
carrier board and then routed to a 68 pin SCSI-3 connector P1, on the 
transition module, for rear exit from the card cage. This module is available 
for use in card cages which provide rear exit for I/O connections via 80 mm 
wide transition modules (transition modules can only be used in card cages 
specifically designed for them). It is a single-height (3U), single-slot module 
and adheres to the CompactPCI mechanical dimensions and IEEE Standard 
(1101.11-1998), with a printed circuit board depth of 80mm, which is a 
standard transition module depth.  The transition module connects to 
Acromag Termination Panel (Model 5025-288) using a round 68 conductor 
shielded cable (Model 5028-432) to the rear of the card cage, and to the 
ACPC4610E board within the card cage. 

 

Model TRANS-C5210 Transition Module:  Same as TRANS-C4610, 

except I/O signals routed as differential pairs for the FPGA PMC Modules.   

 

Model 5028-432: A 2-meter cable, with a male SCSI-3 connector at both 

ends and 34 twisted pairs.  This cable is used for connecting the TRANS-
C4610/-C5210 board to Model 5025-288 termination panels. 

 

Model 5025-288: DIN-rail mountable panel provides 68 screw terminals 

for universal field I/O termination.  Connects to the TRANS-C4610/-C5210 
board, via SCSI-3 to twisted pair cable, Model 5028-432.  

1.0  GENERAL 
INFORMATION 

MODEL ACPC4610E 

KEY FEATURES 

MODEL ACPC4610CC 

KEY FEATURES 

CompactPCI Transition 
Module 

SIGNAL INTERFACE 
PRODUCTS 

Cables 

Termination Panel 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание ACPC4610E/CC

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...0765 South Wixom Road Fax 248 624 9234 P O BOX 437 Wixom MI 48393 7037 U S A Solutions acromag com Copyright 2008 Acromag Inc Printed in the USA Data and specifications are subject to change without n...

Страница 3: ...OCEDURE 7 WHERE TO GET HELP 7 4 0 SPECIFICATIONS PHYSICAL 8 CONNECTORS 8 ENVIRONMENTAL 8 POWER REQUIREMENTS 9 CompactPCI BUS COMPLIANCE 9 RELIABILITY PREDICTION 9 APPENDIX MODEL TRANS C4610 TRANS C521...

Страница 4: ...cooled frame thermo bars ejector injectors and Wedge LoksR designed to thermally conduct heat away from the Conduction Cooled PMC modules per ANSI VITA 30 1 2001 Model TRANS C4610 Transition Module T...

Страница 5: ...equirements Be sure that the system power supplies are able to accommodate the power requirements of the system boards plus the installed Acromag board within the voltage tolerances specified In an ai...

Страница 6: ...CPC4610E CC cannot be used in 64 bit cPCI or PXI systems as rear I O J2 is mapped to the same connector as the additional control lines for 64 bit cPCI or PXI Pin Row A Row B Row C Row D Row E Row F 1...

Страница 7: ...3 INTA INTB INTC 5V INTD GND 4 IPM PWR HEAL V I 0 INTP INTS GND 5 BR A5 BR B5 RST GND GNT GND 6 REQ GND 3 3V CLK AD 31 GND 7 AD 30 AD 29 AD 28 GND AD 27 GND 8 AD 26 GND V I O AD 25 AD 24 GND 9 C BE 3...

Страница 8: ...our PMC module to verify that it is correctly configured Replacement of the board with one that is known to work correctly is a good technique to isolate a faulty board If you continue to have problem...

Страница 9: ...gy R Bridge Chip PCI6540 primary side Type A right angle female connector 110 contacts with upper shield Note This board is universal 3 3V or 5V signal tolerant J2 CompactPCI Rear I O PMC on CompactPC...

Страница 10: ...Watts Total of all supplies per PMC standard Maximum Power for Rear Transition Modules 3 3 VDC Maximum 3 Amps Fused at 4 Amps 5 5 VDC Maximum 2 Amps Fused at 3 Amps Note Model TRANS C4610 does not us...

Страница 11: ...d 0 063 inches thick Operating Temperature 40 C to 85 C Storage Temperature 55 C to 100 C Shipping Weight 0 25 pounds 0 11Kg packed Type Transition module for ACPC4610 boards Same as TRANS C4610 excep...

Страница 12: ...um at 50 energized SCSI 3 connector spec s Operating Temperature 30 C to 80 C Storage Temperature 40 C to 85 C Shipping Weight 1 0 pound 0 5Kg packed Type Termination Panel For CompactPCI Boards Appli...

Страница 13: ...__ __________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 12 Model ACPC4610E J1 J2 F1...

Страница 14: ...__ __________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 13 Model ACPC4610CC J1 J2 A...

Страница 15: ...romag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 14 J1 J12 J11 J2 J14 Compact PCI BUS PMC CONNECTORS PMC SLOT 1 4502 096B 5 VDC 3 3 VDC ACPC4610 BLOCK DIAGR...

Страница 16: ...___________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 15 Model TRANS C4610 TRANS C5210 TP1...

Страница 17: ...25 A9 24 B9 23 C9 22 D9 21 E9 20 A10 19 B10 18 C10 17 D10 16 E10 15 A11 14 B11 13 C11 12 D11 11 E11 10 A12 09 B12 08 C12 07 D12 06 E12 05 A13 04 B13 03 C13 02 D13 01 E13 RJ2C RIO0_N RIO1_N RIO0_P RIO1...

Страница 18: ...E8 25 A9 24 B9 23 C9 22 D9 21 E9 20 A10 19 B10 18 C10 17 D10 16 E10 15 A11 14 B11 13 C11 12 D11 11 E11 10 A12 09 B12 08 C12 07 D12 06 E12 05 A13 04 B13 03 C13 02 D13 01 E13 J2C RIO1_P RIO1_N RIO0_P RI...

Страница 19: ...22 25 24 18 17 19 18 17 20 19 P2 12 15 14 13 12 15 14 8 7 9 10 8 7 9 10 3 2 5 4 2 5 4 3 P2 P1 64 66 2 METERS 61 60 59 58 54 53 56 55 49 48 51 50 43 44 46 45 39 38 41 40 33 36 35 34 28 30 29 23 22 25...

Страница 20: ...____________________________ __________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 1...

Страница 21: ...i e Memory of whose contents are lost when power is removed Yes No Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Type SRAM SDRAM etc Size User Modifiable Yes No Functio...

Страница 22: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...