background image

1

03.09244.005

BOTTOM PLATE

2

03.05634.005

ASH LIP

3

03.00395.002

FLUE COLLAR

4

03.52269.005

LEG

5

03.37696.002

AIR TUNNEL

6

03.02476.005

BACK PLATE

7

03.15366.005

BLANKING PLATE

8

03.07216.002

LOCKING PLATE

9

03.79287.005

SIDE LEFT CASTING

10

03.03198.005

COVER PLATE

11

03.79290.005

SIDE RIGHT CASTING

12

03.24473.005

FRONT UPPER CASTING

13

03.37105.002

AIR DEFLECTOR

14

03.37693.002

AIR TUNNEL

15

03.15981.005

DOOR

16

03.69228.005

TOP PLATE

17

03.00314.100

FLUE COLLAR Ø125 INSIDE

18

03.66545.002

FIRE GRATE

19

03.77527.000

BACK FIRE BRICK x 2

20

03.77526.000

SIDE FIRE BRICK x 2

21

03.77543.000

VERMICULITE BAFFLE PLATE

22

03.77430.002

LOG RETAINER

23

03.38016.000

DRAFT CONTROL PRIMARY

24

03.38017.000

DRAFT CONTROL SECONDARY

25

03.38018.000

DRAFT CONTROL TERTIARY

26

03.31452.000

CLAMPING PLATE

27

03.37697.000

AIR TUNNEL

28

02.27046.000

LATCH

29

03.05241.000

ASH BOX

30

03.26374.000

GLASS

31

03.26163.000

GLASS RETAINER

32

03.29042.000

SUPPORT ROPE

33

03.26101.041

GLASS RETAINER

34

03.22201.041

HEXAGON FLANGE BOLT M8X20 BLACK

35

03.13612.000

BUSH Ø12XØ8X3.5

36

03.18710.000

WASHER 8X25

37

04.26419.000

GLASS FIBRE ROPE Ø6MM SELF ADHESIVE

38

03.22204.041

HEXAGON FLANGE BOLT M8X35 BLACK

39

03.22202.041

HEXAGON FLANGE BOLT M8X30 BLACK

40

03.76320.000

ADJUSTBLE LEG

42

04.26422.000

GLASS FIBRE BAND 10X3MM SELF ADHESIVE

43

03.19505.000

STUD M6X35

44

03.18701.000

WASHER 6X18

45

03.19410.000

HEXAGON NUT M6

46

03.19303.041

HEXAGON HEAD SCREW M6X12

47

03.13623.041

BUSH Ø13XØ10X7.5

48

03.13619.100

BUSH LATCH 10X8.5X6

49

03.19304.000

HEXAGON HEXAGON HEAD SCREW M6X16

50

03.18601.041

SCREW M6X12

51

03.18605.041

SCREW M6X30 BLACK

52

03.19507.000

STUD M8X20

53

03.22203.041

HEXAGON BLIND RIVET NUT M8

54

03.19701.000

SCREW M8X25

55

03.19401.000

HEXAGON NUT M8

56

04.26408.000

GLASS FIBRE ROPE Ø8MM

58

03.13644.041

BUSH LOCKING Ø11.5XØ9X7.4

59

03.16601.000

SPRING WASHER 6MM

60

03.20360.000

SCREW M6X16

61

03.21701.041

SET SCREW M6X6 BLACK

62

03.17806.000

COILED SPRING PIN 6X30

63

03.58610.100

HINGE PIN

65

04.26420.000

GLASS FIBRE ROPE Ø8MM SELF ADHESIVE

66

03.19801.041

SCREW M5X10 BLACK

Diagram No.

Part No.

Description

Oakdale FB1 A5 0414-1  30/04/2014  16:27  Page 13

Содержание Oakdale FB1MF

Страница 1: ...r for future reference Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L Document FB1MF 0101 Version 1 Date 03 03 14 Serial Number MULTI FUEL DEFRA APPROVED AIRWASH SYSTEM 5 YEAR 5 YEAR WARRANTY Oakdale FB1 A5 0414 1 30 04 2014 16 27 Page 1 ...

Страница 2: ...ance to ensure safety A fire guard should be fitted if it is likely that the elderly infirm or children may come into contact with the appliance This appliance must not be used as an incinerator This appliance has been designed for intermittent operation To ensure that you gain the most from your purchase please take a few minutes to read through this manual before lighting the appliance for the f...

Страница 3: ...rmeability 5 0m h m then 550mm kW of appliance rated output If in doubt please consult your registered installer for advice Nominal heat output 5 kW Wood 5 kW Smokeless Fuel Chimney draft required 12Pa Height 550 mm Width 440 mm Depth 370 mm Weight 90 kg Air Requirement N A Flue Mass Gas Flow 3 4g s Wood 4 7g s Smokeless Fuel CO 13 O2 0 08 vol Mean Flue Gas Temperature 274 C Wood 273 C Smokeless F...

Страница 4: ...uel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The Oakdale FB1MF has been recommended as suitable for use in smoke control areas when burning wood as such when the secondary air slider is in the closed position it remains open by 25mm and the tertiary air control should be fully ope...

Страница 5: ...s enough space should be left around the appliance to enable the heat produced to rise and escape from the recess back into the room Hearth Requirements The appliance must stand on a level fireproof hearth with a minimum thickness of 12mm The hearth temperature created by this stove is below 100 C The hearth must protrude at least 300mm in front of the appliance and 150mm either side of the applia...

Страница 6: ...moke exempt stop Under no circumstances should it be tampered with or removed unless expressly authorised by a competent person and the appliance is not installed in a smoke exempt area If the appliance is to be installed in a non smoke exempt area you can remove the restricting screw on the secondary air control indicated by the two holes to allow full movement of the secondary air slider The app...

Страница 7: ...e has overheated the appliance and flue will need to be inspected for any damage before it can be operated again Recommended Fuels Wood hardwood such as ash oak and beech which have been cut for at least 2 years and stored under shelter The logs should have a maximum moisture content of 20 Maximum log length 300mm maximum width 125mm Smokeless Fuels below 20 Petroleum coke content such as Anthraci...

Страница 8: ...red by moving the secondary air slider marked with a double hole push the lever inwards to close down and pull outwards to increase the burn rate Care should be taken to ensure that the logs are not placed higher than the log guard allows This stove features a split log guard to allow differing loads to be managed only alter the log guard when the appliance is fully cold Instructions for use with ...

Страница 9: ...n this manual should not be exceeded overloading can cause excess smoke Operation with door left open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as directed in the instructions Air controls left open Operation with the air controls or appliance dampers open fully can cause damage to the appliance The appliance mus...

Страница 10: ...ual basis to ensure the correct operation of this appliance The glass can be cleaned using a soft damp cloth or a ceramic glass cleaner available from your local stockist Use only replacement parts recommended by the manufacturer We recommend that the appliance is serviced annually by a competent engineer to ensure it s continued safe operation Fire difficult to Green wood wet wood Use hardwood lo...

Страница 11: ...f during the first firings as the paint cures Advise the customer on the safe operation of the appliance Leave the instruction manuals operating tool and glove for the customer s use Record the flue draught reading of the appliance Please tick boxes when each procedure is completed To remove the internal vermiculite baffle Firstly remove the front fuel retaining bars Then slightly lift the baffle ...

Страница 12: ...Parts Information Oakdale FB1 A5 0414 1 30 04 2014 16 27 Page 12 ...

Страница 13: ...ER 34 03 22201 041 HEXAGON FLANGE BOLT M8X20 BLACK 35 03 13612 000 BUSH Ø12XØ8X3 5 36 03 18710 000 WASHER 8X25 37 04 26419 000 GLASS FIBRE ROPE Ø6MM SELF ADHESIVE 38 03 22204 041 HEXAGON FLANGE BOLT M8X35 BLACK 39 03 22202 041 HEXAGON FLANGE BOLT M8X30 BLACK 40 03 76320 000 ADJUSTBLE LEG 42 04 26422 000 GLASS FIBRE BAND 10X3MM SELF ADHESIVE 43 03 19505 000 STUD M6X35 44 03 18701 000 WASHER 6X18 45...

Страница 14: ...o the following conditions The appliance must have been installed by a registered competent installer HETAS or inspected by local authority Building Control The appliance must be installed and operated in accordance with our instruction manual The guarantee is for a period of 5 years on the appliance body from the date of purchase The following components are considered as consumables and are excl...

Страница 15: ...ng Control Certificate Number if not installed by a registered competent installer Dealer Name and address In the unlikely event of a warranty claim please return the above claim form to ACR Heat Products Limited Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Oakdale FB1 A5 0414...

Страница 16: ...imited Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Oakdale FB1 A5 0414 1 30 04 2014 16 28 Page 16 ...