Oakdale Specifications
*** Please note that Building Regulations Document J advises that additional permanent air supply is
required for appliances with an output of above 5Kw.
With modern properties additional air may be required as Document J suggests that adequate air
would be a benefit.
• If design air permeability
≥
5.0m³/ (h.m²) then 550mm²/kW of appliance rated output above 5kW
Or
• If design air permeability
≤
5.0m³/ (h.m²) then 550mm²/kW of appliance rated output
• If in doubt, please consult your registered installer for advice.
Nominal heat output
5 kW - Wood
5 kW – Smokeless Fuel
Chimney draft required
12Pa
Height
550 mm
Width
440 mm
Depth
370 mm
Weight
90 kg
Air Requirement
N/A ***
Flue Mass Gas Flow
3.4g/s - Wood
4.7g/s - Smokeless Fuel
CO @ 13% O
2
0.08 vol %
Mean Flue Gas Temperature
274°C - Wood
273°C - Smokeless Fuel
Efficiency
78.3% - Wood
81.5% - Smokeless Fuel
Log Length
Up To 300 mm
NOTE: DO NOT INSTALL IN A ROOM CONTAINING AN EXTRACTOR FAN
550
430
120
440
370
Oakdale FB1 A5 0414-1 30/04/2014 16:27 Page 3